Model 3910 Available Versions: Custom gage lengths are available. Gage Length Օ DESIGNATIONGAGE LENGTH Two 3910 units mounted on asphalt test sample. 1 Special order only. Example: 3910-0100: 1.000 inch (25.4 mm) gagelength with a full scale measuring range of 0.020 inches (0.5 mm) S PECIFICATIONS Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Output: 2 to 4 mV/V nominal, depending on model Linearity: ≤ 0.20% of full scale measuring range, dependingon model Temperature Range: Standard is -40 C to +100 аC (-40 F to +210 аF) Cable: Integral, flexible Teflon > cable, 8 ft. (2.5 m)standard Operating Force: <30 g typical > O PTIONS 3910 on one side of test sample. Connectors to interface to nearly any brand test equipment Shunt calibration module (see page 96) Gage length adapters Gluing template for gage points > 51.82.041.7644.72.0451.8 3910 WITH 1Δ GAGE LENGTH3910 WITH 1.5 GAGE LENGTH 3910 gage point gluingtemplate on sample.3910 template, specimenside. Contact Epsilon for your special testing requirements. 64.52.542.5464.51.7644.7 DIMENSIONS:[mm] inches