1. Catalogs
  2. Epsilon Technology
  3. 3541 Fracture Mechanics Clip-On Gages

3541 Fracture Mechanics Clip-On Gages

3541 Fracture Mechanics Clip-On Gages

3541 Fracture Mechanics Clip-On Gages

Product catalog summary
Overview: The document provides detailed information about the Model 3541 Crack Opening Displacement (COD) gages used in fracture mechanics studies. These gages comply with standardized test methods such as ASTM E1820 for determining fracture toughness properties of metallic materials.
Specifications: The Model 3541 is designed to determine fracture mechanics parameters like JIC, KIC, R-curve, and fatigue crack growth rate (da/dN). It conforms to ASTM standards such as E1820, E399, and E647. Special configurations are available for ASTM E399 requirements. The gages feature a modified groove design for enhanced stability and accuracy.
Features: The COD gages are strain-gaged devices compatible with electronics designed for strain-gaged transducers. They can be connected to test machine controllers or data acquisition systems. The gages are fully enclosed for protection, have sharp grooves for improved stability, and include the Epsilon Shunt Calibration System for on-site calibration.
Ordering Information: Various versions of the Model 3541 are available with different gauge lengths and measuring ranges. Special models are available for other fracture mechanics tests, such as ASTM E1304. The document provides examples of model numbers and configurations.
Technical Specifications: The gages operate with an excitation of 5 to 10 VDC, have an output of 2 to 4 mV/V, and meet accuracy requirements of ASTM E1820, ISO 12135, and ISO 9513 Class 1. They have a linearity of ≤0.2% of full scale measuring range and operate within specified temperature ranges.
Options: The document mentions available options such as connectors for various test equipment, special versions for narrow grips, and bolt-on knife edges. It also references Model 4030COD for applications requiring submersion in liquids.
See more

Catalog excerpts

3541 Fracture Mechanics Clip-On Gages-1

3541 Fracture Mechanics Clip-On Gages For fracture mechanics studies, these COD gages are in compliance with standardized test methods, such as ASTM E1820 for determination of fracture toughness properties of metallic materials. Model 3541 attached to bolt-on knife edges Model 3541-012M-120M with 12 mm gauge length and +12/-2 mm measuring range The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 for JIC and R-curve Model 3541 COD gage determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configur tions). In addition, a the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organiza ion’s test methods. Clip-on gages can be t used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen. Model 3541 crack opening displacement gages are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller with electronics for a strain channel, and Epsilon will equip the extensometer with a compatible connector that is wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of signal conditioning solutions that enable connecting to data acquisition systems or other equipment. See the electronics section of this catalog for available signal conditioners and strain meters. Visit our website at www.epsilontech.co

 Open the catalog to page 1
3541 Fracture Mechanics Clip-On Gages-2

Ordering Information May be left on through specimen failure. bridge, 350 ohm strain gaged design for compatibility with nearly any test system. enclosed gages are protected from accidental damage. grooves per ASTM E1820, E813, and E399 for improved stability when mounted. da/dN testing or pre-cracking, where maximum frequency (>50 Hz) is required, minimum measuring ranges are recommended. KIC/JIC testing, maximum accuracy is achieved with the smallest measuring range and the largest gauge length that will perform the test. operating frequency may be from 5 Hz to >200 Hz depending on COD gage...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.