PL Series
1Pages

{{requestButtons}}

Catalog excerpts

PL Series - 1

Uninterruptible Power Supplies GENERAL SPESIFICAITIONS True On-line Topology / Sinusoidal Output IGBT / IPM Technology (İnverter Side) Thyristor Control Rectifier 6 or 12 pulse application Galvanic Isolation at the Output of the Inverter Static and Maintenance By-Pass Advanced Automatic and Manual Battery Test System Non-Linear Load Driving Capability RS232 and Dry Contacts or RS485, Modbus Communication and Remote Monitoring. High Efficiency up to 94%. Space Vector Application. High Performance Design. Overload and Short Circuit Protection. Utility&Generator Friendly Compatible with International Standards Flexi Power Walk-In Temperature Compensated Battery Charging Hot Standby Configuration Advanced 2x16 or 4x20 LCD Panel Providing Detailed) Information (Input/Output Voltage, Battery Voltage, Charging Current, Interior Temperature and Setting User Selectable Parameters) 200 Recorded Event History. Alarm Logging. Compact and Quiet. ISO9001, ISO14001 Certified 10-Years Spare Parts Availability Guarantee Year-Round 24-Hour Emergency Technical Support Options: Parallel Aplication Touching Display IGBT Rectifier Technical Specifications MODELS Power kVA INPUT Input Voltage Input Voltage Range Input Frequency OUTPUT Power (kW) Power Factor Output Voltage Voltage Stability Correction Time Frequency Frequency Tolerance Efficiency of %100 Load Total Harmonic Distortion Crest Factor Excessive Load Protection Short Circuit Protection BATTERY Type Battery Number Charge Voltage (Vdc) Discharge Voltage (Vdc) Ambient Temperature Battery Test GENERAL Series Communication Software Operating Temperature Interval Cooling Relative Humidity Operating Height Acoustic Noise Weight Without Battery Dimensions (mm) (HxWxD) 80 96 128 160 200 240 320 0.8 120/208 Vac or 230 / 400 Vac, 220 / 380 Vac 3 phase + Neutral (Balanced load: ± %1) (Unbalanced load: ± %2.5) (Step load: ± %5) After step load: Max 25 ms. 50 Hz or 60Hz Adjustable + % 2 (synchronous) , +%0.2 (free operation) 87-91% 90-92% 92-94% <%3 (for linear loads) <%7 (for non-linear loads) 3:1 (100% 125% load: 10min.) (125% 150% load: 1min.) (>150% load: by-pass) Short circuit protection electronically Maintenance free lead-acid APPLICATION STANDARDS EMC, Safety IEC62040-1, IEC62040-2 Protection Class IP20 Quality Assurance ISO14001 - ISO9001 certified OPTIONS Input Transformer Isolated transformer at the input. Input Harmonic Distortion THD* %5 (12 pulse rectifier and filter) Input Power Factor** 0.90 (With additional filter or 12 pulse rectifier and filter) MBS Full isolation with maintenance by-pass Operating In Parallel 1+3 system (Standby, Current sharing, Parallel Redundant) (*) 12 pulsed rectifier (**) There can be a change in standard dimensions or additional filter or 12 pulsed rectifier and filter applications. NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications. All names used above are registered trademarks of their respective owners.

Open the catalog to page 1

All EPC ENERGY AND POWER CONVERSION catalogs and technical brochures

  1. STS Series

    4 Pages

  2. SVR Series

    2 Pages

  3. FC Series

    2 Pages

  4. SD series

    7 Pages

  5. HI-RECT

    7 Pages

  6. GC Series

    11 Pages