The SPARKGAS 30 P gas burners operate within a thermal output range of 60 to 300 kW. They conform to the Gas Directive 90/396/CEE, E.M.C. Directive 89/336/CEE, and L.V. Directive 73/23/CEE, with reference to standard EN676. These burners are designed for two-stage operation, allowing for high and low flame settings.
Technical and Functional Characteristics:
  • Two-stage operation with air-gas mixing at the blast-pipe.
  • Optimal combustion values can be achieved by regulating combustion air and the blast-pipe.
  • Maintenance is simplified as the mixing unit can be removed without detaching the burner from the boiler.
  • Air flow regulation for both stages is managed by an electric servomotor, which includes a pause closure of the gate to prevent heat dispersion.
  • Optional gas train with valve tightness control is available.
  • Equipped with connectors, a flange, and an insulating seal for boiler fastening.
  • Optional longer blast tube available on request.
Construction Characteristics:
  • Combustion air intake with an air flow adjustment device.
  • Sliding boiler coupling flange to adapt to various boiler types.
  • Sound-absorbing material used to reduce fan noise.
  • Air pressure switch ensures the presence of combustion air.
  • Automatic control and command equipment compliant with EN298.
  • Flame detection via ionisation electrode.
  • Start/stop switch and stage selector (except W version).
  • Electrical protection rating of IP40.
  • Sound-proof plastic protective cover (except W version).
Accessories and Options:
  • Gas train complete with operation and safety valve, minimum pressure switch, pressure regulator, and gas filter.
  • Soundproof burner cover and longer combustion head available as optional accessories.
Performance and Compatibility:
  • Burners are compatible with both natural gas and LPG, with specific gas train versions for CE and EXP markets.
  • Pressure drop and thermal output graphs are provided for performance analysis.
See more

Catalog excerpts

SparkGas 30 P-1

Conform to: Gas Directive 90/396/CEE E.M.C. Directive 89/336/CEE L.V. Directive 73/23/CEE Reference standard: EN676 WHILE STOCK LASTS TECHNICAL AND FUNCTIONAL CHARACTERISTICS • Two-stage operation (high/low flame). • Air-gas mixing at blast-pipe. • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe. • Maintenance facilitated by the fact that the mixing unit can be removed without having to remove the burner from the boiler. • Air flow regulation for first and second stage by means of electric servomotor with pause closure of gate to prevent any heat dispersion to flue. • Possibility to chose gas train with valve tightness control. • Equipped with one 4 and 7-pole connector, one flange and one insulating seal for boiler fastening. • On request: longer blast tube. CONSTRUCTION CHARACTERISTICS The burner consists of: (except the W version). • Combustion air intake with air flow • 7-pole outlet for burner electrical and adjustment device. thermostat connections, and 4-pole outlet • Sliding boiler coupling flange to adapt the for second stage control. head protrusion to the various types of • Electrical protection rating IP40. boilers. • Sound-proof plastic protective cover • Device made from sound-absorbing (except the W version). material to reduce fan noise. • Air pressure switch to ensure the presence To be ordered separately: of combustion air. • Gas train complete with operation and • Automatic control and command safety valve, minimum pressure switch, equipment for the burner, compliant with pressure regulator and gas filter. European standard EN298. • Flame detection by ionisation electrode. • Start/stop switch, 1st /2nd stage selector Electrical supply Accessories available on request Part no. 97980054 Soundproof burner cover (see page 247) Optionals 500 mm long combustion head Boiler coupling kit – 4 and 7 pin plug 4 Soundproof lid on burner air intake. Equipped with air closure device. Valve tightness control not required by EN676. Gas train with Valve Tightness Control. Minimum gas train inlet pressure needed to obtain maximum burner power with a combustion chamber backpressure of zero. **) Maximum gas inlet pressure at pressure regulator in CE version, at gas train for EXP version. Net calorific value at reference conditions of 0°C, 1013mbar: Natural gas HI 35,8MJ/m3 = 8550 kcal/m3 LPG HI 92MJ/m3 = 22000 kcal/m3

 Open the catalog to page 1
SparkGas 30 P-2

Burner/gas train match CE gas train version complies with EN676, EXP gas train version is for extra-European markets Gas type Curve on Execution P.Max** graph mbar SPARKGAS 30 PW NATURAL CE / EXP SPARKGAS 30 P GAS Burner model P.Min* mbar Regulator with incorporated filter Part no. Included Included Included Included Included Included Regulator with incorporated filter Part no. Included Included To choose the correct gas train please refer to the information on page 10. For information on the structure, composition, and size of the gas train please refer to the diagrams on page 234. Pressure...

 Open the catalog to page 2

All EOGB energy products ltd catalogs and technical brochures

  1. TBG 140 LX PN

    2  Pages

  2. TBG 80 LX PN

    2  Pages

  3. GI 510 DSPGN

    2  Pages

  4. GI 350 DSPGN

    2  Pages

  5. BTG 28 ME

    2  Pages

  6. TBG 45 P

    2  Pages

  7. TBG 35 P

    2  Pages

  8. SparkGas 35 P

    2  Pages

  9. TBG 45

    2  Pages

  10. TBG 60

    2  Pages

  11. TBG 35

    2  Pages

  12. BTG

    8  Pages

  13. GI 1000 DSPG

    1  Page

  14. GI

    1  Page

  15. BT

    2  Pages

  16. Spark 35 DSG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.