
Catalog excerpts

Conform to: Gas Directive 90/396/CEE E.M.C. Directive 89/336/CEE L.V. Directive 73/23/CEE Reference standard: EN676 WHILE STOCK LASTS TECHNICAL AND FUNCTIONAL CHARACTERISTICS • Two-stage operation (high/low flame). • Air-gas mixing at blast-pipe. • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe. • Maintenance facilitated by the fact that the mixing unit can be removed without having to remove the burner from the boiler. • Air flow regulation for first and second stage by means of electric servomotor with pause closure of gate to prevent any heat dispersion to flue. • Possibility to chose gas train with valve tightness control. • Equipped with one 4 and 7-pole connector, one flange and one insulating seal for boiler fastening. • On request: longer blast tube. CONSTRUCTION CHARACTERISTICS The burner consists of: (except the W version). • Combustion air intake with air flow • 7-pole outlet for burner electrical and adjustment device. thermostat connections, and 4-pole outlet • Sliding boiler coupling flange to adapt the for second stage control. head protrusion to the various types of • Electrical protection rating IP40. boilers. • Sound-proof plastic protective cover • Device made from sound-absorbing (except the W version). material to reduce fan noise. • Air pressure switch to ensure the presence To be ordered separately: of combustion air. • Gas train complete with operation and • Automatic control and command safety valve, minimum pressure switch, equipment for the burner, compliant with pressure regulator and gas filter. European standard EN298. • Flame detection by ionisation electrode. • Start/stop switch, 1st /2nd stage selector Electrical supply Accessories available on request Part no. 97980054 Soundproof burner cover (see page 247) Optionals 500 mm long combustion head Boiler coupling kit – 4 and 7 pin plug 4 Soundproof lid on burner air intake. Equipped with air closure device. Valve tightness control not required by EN676. Gas train with Valve Tightness Control. Minimum gas train inlet pressure needed to obtain maximum burner power with a combustion chamber backpressure of zero. **) Maximum gas inlet pressure at pressure regulator in CE version, at gas train for EXP version. Net calorific value at reference conditions of 0°C, 1013mbar: Natural gas HI 35,8MJ/m3 = 8550 kcal/m3 LPG HI 92MJ/m3 = 22000 kcal/m3
Open the catalog to page 1
Burner/gas train match CE gas train version complies with EN676, EXP gas train version is for extra-European markets Gas type Curve on Execution P.Max** graph mbar SPARKGAS 30 PW NATURAL CE / EXP SPARKGAS 30 P GAS Burner model P.Min* mbar Regulator with incorporated filter Part no. Included Included Included Included Included Included Regulator with incorporated filter Part no. Included Included To choose the correct gas train please refer to the information on page 10. For information on the structure, composition, and size of the gas train please refer to the diagrams on page 234....
Open the catalog to page 2All EOGB energy products ltd catalogs and technical brochures
-
TBG 140 LX PN
2 Pages
-
TBG 80 LX PN
2 Pages
-
SparkGas 30 LX
2 Pages
-
GI 510 DSPGN
2 Pages
-
GI 350 DSPGN
2 Pages
-
BTG 28 ME
2 Pages
-
TBG 45 P
2 Pages
-
TBG 35 P
2 Pages
-
SparkGas 35 P
2 Pages
-
TBG 45
2 Pages
-
TBG 60
2 Pages
-
TBG 35
2 Pages
-
SparkGas 35 (BGS 35)
2 Pages
-
SparkGas 30 (BGS 30)
2 Pages
-
BTG
8 Pages
-
GI 1000 DSPG
1 Pages
-
GI
1 Pages
-
Low NOx models
1 Pages
-
BT
2 Pages
-
Spark 35 DSG
1 Pages
-
XSeries Burners
2 Pages