Spark 35 DSG

Spark 35 DSG

Product catalog summary
Technical and Functional Characteristics
  • The SPARK 35 DSG burners operate in two stages (high/low flame) and allow for optimal combustion by adjusting combustion air and blast-pipe.
  • Maintenance is simplified as the atomisation unit can be removed without detaching the burner from the boiler.
  • Airflow regulation for both stages is managed by an electric servomotor, which includes a gate closure to prevent heat loss.
  • For biodiesel light oil usage, specific components such as flexible hoses, line filter, and pump are required.
  • The burner is equipped with connectors, a flange, an insulating seal, flexible hoses, a line filter, and nozzles. Longer blast tubes and biodiesel operation are available upon request.
Construction Characteristics
  • The burner includes a combustion air intake with an air flow adjustment device and a sliding boiler coupling flange for head protrusion adaptation.
  • Sound-absorbing materials are used to reduce fan noise, and a gear pump with a pressure regulator and fuel stop-cock valves is included.
  • Automatic control and command equipment comply with European standard EN230, with flame detection by photoresistance.
  • Electrical connections are facilitated by a 7-pole outlet for burner and thermostat connections, and a 4-pole outlet for second stage control. The electrical protection rating is IP40.
  • A sound-proof plastic protective cover is provided, except for the W version.
Specifications and Standards
  • The burners conform to E.M.C. Directive 89/336/CEE and L.V. Directive 73/23/CEE, with reference standard EN267.
  • Biodiesel must comply with European norm EN14213-FAME, with a net calorific value of light oil at 42.70 MJ/kg.
Models and Accessories
  • Models include SPARK 35 DSG and SPARK 35 DSGW, with thermal outputs ranging from 178 to 391 kW.
  • Accessories available include line filters, flex hoses, nozzles, and a boiler coupling kit. Optional accessories include a 500 mm long combustion head and biodiesel operation capability.
  • Soundproof burner covers are available as an accessory.
See more

Catalog excerpts

Spark 35 DSG-1

Conform to: E.M.C. Directive 89/336/CEE L.V. Directive 73/23/CEE Reference standard: EN267 TECHNICAL AND FUNCTIONAL CHARACTERISTICS Two-stage light oil burners • Two-stage operation (high/low flame). • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe. • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler. • Air flow regulation for first and second stage by means of electric servomotor with pause closure of gate to prevent any heat dispersion to flue. • When using biodiesel light oil (fuel of vegetable origin), the burner must be built with specific components: flexible hoses, line filter and pump. • Equipped with one 4 and 7-pole connector, one flange and one insulating seal for boiler fastening, 2 flexible hoses, one line filter and two nozzle. • On request: longer blast tube, operation on biodiesel. CONSTRUCTION CHARACTERISTICS SPARK 35 DSGW SPARK 35 DSG The burner consists of: • Flame detection by photoresistance. • Combustion air intake with air flow • 7-pole outlet for burner electrical and adjustment device. thermostat connections, and 4-pole outlet • Sliding boiler coupling flange to adapt the for second stage control. head protrusion to the various types of • Electrical protection rating IP40. boilers. • Sound-proof plastic protective cover • Device made from sound-absorbing (except the W version). material to reduce fan noise. • Gear pump with pressure regulator and fuel stop-cock valves. • Automatic control and command equipment for the burner compliant with European standard EN230. Electrical supply SPARK 35 DSGW SPARK 35 DSG SPARK 35 DSGW SPARK 35 DSG Accessories available on request 97980054 Soundproof burner cover (see page 247) 500 mm long combustion head Biodiesel operation (5) Light oil burner accessories Line filter - Flex hoses - Nozzles - Boiler coupling kit - 4 and 7 pin plug 3) Soundproof lid on burner air intake. 4) Equipped with air closure device. 5) Biodiesel according to european norm EN14213-FAME. Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.

 Open the catalog to page 1

All EOGB energy products ltd catalogs and technical brochures

  1. TBG 140 LX PN

    2  Pages

  2. TBG 80 LX PN

    2  Pages

  3. GI 510 DSPGN

    2  Pages

  4. GI 350 DSPGN

    2  Pages

  5. BTG 28 ME

    2  Pages

  6. TBG 45 P

    2  Pages

  7. TBG 35 P

    2  Pages

  8. SparkGas 35 P

    2  Pages

  9. SparkGas 30 P

    2  Pages

  10. TBG 45

    2  Pages

  11. TBG 60

    2  Pages

  12. TBG 35

    2  Pages

  13. BTG

    8  Pages

  14. GI 1000 DSPG

    1  Page

  15. GI

    1  Page

  16. BT

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.