Product catalog summary
Technical and Functional Characteristics
  • Single-stage operation with on/off functionality.
  • Optimal combustion values achieved through adjustable combustion air and blast-pipe.
  • Easy maintenance with removable atomisation unit without detaching the burner from the boiler.
  • Manual air flow adjustment available.
  • Specific components required for biodiesel light oil use, including flexible hoses, line filter, and pump.
  • Standard equipment includes a 7-pole connector, flange, insulating seal, two flexible hoses, line filter, and nozzle.
  • Optional features include extended blast-pipe, air gate closure device, and biodiesel compatibility.
Construction Characteristics
  • Combustion air intake with adjustable air flow device.
  • Sliding boiler coupling flange for head protrusion adaptation to various boilers.
  • Sound-absorbing material used to reduce fan noise.
  • Gear pump with pressure regulator and fuel stop-cock valves.
  • Automatic control and command equipment compliant with EN230 standard.
  • Flame detection via photoresistance.
  • 7-pole outlet for electrical and thermostat connections.
  • Electrical protection rating of IP40.
  • Sound-proof plastic protective cover (except W version).
Specifications and Standards
  • Conforms to E.M.C. Directive 89/336/CEE and L.V. Directive 73/23/CEE.
  • Reference standard: EN267.
  • Biodiesel compliance with European norm EN14213-FAME.
  • Net calorific value of light oil: Hi = 42.70 MJ/kg = 10200 kcal/kg.
Accessories and Options
  • Available accessories include a 500 mm long combustion head, automatic air closure device, and biodiesel operation capability.
  • Soundproof burner cover available as an optional accessory.
Model Specifications
  • SPARK 35 and SPARK 35 W models available with thermal output ranging from 178 to 391 kW.
  • Models available for both 50 Hz and 60 Hz frequencies.
  • Electrical supply: 1N AC 230V with motor power of 0.37 kW.
  • Packaging dimensions and weight vary by model.
See more

Catalog excerpts

Single-stage light oil burners SPARK 35-1

Conform to: E.M.C. Directive 89/336/CEE L.V. Directive 73/23/CEE Reference standard: EN267 TECHNICAL AND FUNCTIONAL CHARACTERISTICS CONSTRUCTION CHARACTERISTICS The burner consists of: • 7-pole outlet for burner electrical and • Combustion air intake with air flow thermostat connections. adjustment device. • Electrical protection rating IP40. • Sliding boiler coupling flange to adapt the • Sound-proof plastic protective cover head protrusion to the various types of (except the W version). boilers. • Device made from sound-absorbing material to reduce fan noise. • Gear pump with pressure regulator and fuel stop-cock valves. • Automatic control and command equipment for the burner compliant with European standard EN230. • Flame detection by photoresistance. Electrical supply Single-stage light oil burners • Single stage operation (on/off). with specific components: flexible hoses, • Abilaity to obtain optimal combustion line filter and pump. values by regulating combustion air and • Equipped with one 7-pole connector, one blast-pipe. flange and one insulating seal for boiler • Maintenance facilitated by the fact that fastening, 2 flexible hoses, one line filter the atomisation unit can be removed and one nozzle. without having to remove the burner from • On request: blast-pipe with greater than the boiler. standard protrusion, a device for air gate • Manual air flow adjustment. closure during pause to avoid loss of heat • When using biodiesel light oil (fuel of up flue, biodiesel running. vegetable origin), the burner must be built Accessories available on request 97980054 Soundproof burner cover (see page 247) Optionals Description 500 mm long combustion head Automatic Air Closure Device Biodiesel operation (5) Light oil burner accessories Line filter - Flex hoses - Nozzle - Boiler coupling kit - 7 pin plug Notes 3) Soundproof lid on burner air intake. 5) Biodiesel according to european norm EN14213-FAME. Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.

 Open the catalog to page 1

All EOGB energy products ltd catalogs and technical brochures

  1. TBG 140 LX PN

    2  Pages

  2. TBG 80 LX PN

    2  Pages

  3. GI 510 DSPGN

    2  Pages

  4. GI 350 DSPGN

    2  Pages

  5. BTG 28 ME

    2  Pages

  6. TBG 45 P

    2  Pages

  7. TBG 35 P

    2  Pages

  8. SparkGas 35 P

    2  Pages

  9. SparkGas 30 P

    2  Pages

  10. TBG 45

    2  Pages

  11. TBG 60

    2  Pages

  12. TBG 35

    2  Pages

  13. BTG

    8  Pages

  14. GI 1000 DSPG

    1  Page

  15. GI

    1  Page

  16. BT

    2  Pages

  17. Spark 35 DSG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.