Series 9100
3Pages

{{requestButtons}}

Catalog excerpts

Series 9100 - 1

Product Data Series 9100 Computerized Ambient Monitoring Calibration System performance exceeds U.S. EPA criteria for ozone transfer standards. ® The Environics Series 9100 Computerized Ambient Monitoring Calibration System is an advanced microprocessor controlled instrument for dynamic calibration of ambient air analyzers. The Series 9100 automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases of interest. The 9100 exceeds all U.S. Environmental Protection Agency requirements. Ozone generator pressure compensation ensures repeatable ozone generation at a flow rate and back pressure other than that at which it was originally calibrated. The Series 9100 consists of a single chassis supporting 2 thermal mass flow controllers, an ozone generation module, a mixing zone, a reaction chamber for gas phase titration, and control electronics. Commands are entered from the front panel and displayed on a backlit 25 line by 80 character liquid crystal display. The instrument may also be remotely operated using contact closures or an RS-232 serial data interface. The mass flow controllers are calibrated to a NIST (National Institute of Standards and Technology) traceable primary standard. The calibration data consists of a comparison of desired versus actual flow over the full dynamic range of the instrument with linear interpolation between points. Calibration data is stored in non-volatile memory and may be updated by the user with a suitable standard. SOFTWARE The Series 9100 has six primary routines accessible through "soft" keys, located immediately below their on-screen labels. Concentration Mode: User enters target output gas concentration (ppm or %) for the span gas. The actual concentration is displayed during mixing. Flow Mode: User enters target flow rate (cc's or liters per minute) for the span gas and dilution gas. Actual flow rates are displayed after mixing is initiated. 25 line by 80 character display permits editing and viewing of an entire 7 day schedule of calibration events in worksheet format. Volts Mode: User enters a command voltage to the mass flow controller and the ozone generator. The actual voltage is displayed during operation. Automatic calculation of dilution and span gas flows based on commanded concentration eliminates the need for manual computation and allows rapid transition from point to point. Program Mode: Permits multi-event programming and unattended automatic operation of the instrument over a seven-day schedule. Calibrate Mode: User enters new calibration data for each of the 9100's mass flow controllers and ozone generator (can be password protected). Maintain Ports: User enters the name of the span gas in the source cylinder, its concentration (ppm) and the port to which the cylinder is connected. The Series 9100 ozone generator is factory calibrated using a NIST traceable ozone standard. This temperature controlled, ultra-violet (UV) based ozone generator includes a precision photo-optical feedback circuit to compensate for lamp aging effects as well as built-in pressure compensation. The Series 9100 is available in either a standard 19” rack mount or bench top configuration. PRODUCT FEATURES AND BENEFITS Internally-stored mass flow controller calibration data improves accuracy by as much as a factor of ten and simplifies field recalibration. Internally-stored ozone generator calibration data insures linear, repeatable ozone generation without photometer control. Ozone generator

Open the catalog to page 1
Series 9100 - 2

SPECIFICATIONS Mass Flow Controller (as a percent of setpoint) * From 10 to 100% of Full Scale Flow ± 1.0% ± 1.0% Flow ± 0.05% Accuracy Concentration: Flow: Repeatability Dimensions (w x h x d) Portable: 17” x 7” x 23.5” (43.18 cm x 17.78 cm x 59.69 cm) Rack: * Mass flow controllers are calibrated using a NIST traceable Primary Flow Standard, using a Reference Temperature of 25 o C (77oF) and a Reference Pressure of 760mm Hg (29.92 in. Hg) Warm up time: 30 minutes Response time: 30 seconds to ±2.0% of setpoint Ozone Generator Concentration Range: 0.5 - 1.00ppm at 10 slpm Accuracy: ±2% or...

Open the catalog to page 2

All Environics catalogs and technical brochures

  1. Series 4020

    2 Pages

  2. Series 2040

    2 Pages

  3. Series 4040

    2 Pages

  4. Series 2020

    2 Pages

  5. Series 2014

    2 Pages

  6. Series 2010

    2 Pages

  7. Series 3000

    2 Pages

  8. Series 4000

    2 Pages

  9. Series 2000

    2 Pages

  10. Series 6103

    2 Pages

  11. Series 6100

    2 Pages

Archived catalogs

  1. ROBD2

    2 Pages