Catalog excerpts
Product Data Series 2014 Computerized VOC Gas Dilution System Environics ® GENERAL DESCRIPTION ® The Environics Series 2014 Computerized VOC Gas Dilution System is a microprocessor based gas dilution system designed for the preparation of calibration standards used for VOC (Volatile Organic Compounds) monitoring programs. The Series 2014 can be used to dynamically produce ppb level standards from ppm level cylinder gases. EPA methods for VOC’s specify a dynamic dilution to produce the initial multi-point calibration as well as the required daily and pre-sample calibration at the nominal 10 ppb level. The Series 2014 employs mass flow controllers calibrated to a NIST (National Institute of Standards and Technology) traceable primary standard. All gas wetted surfaces are electropolished stainless steel to minimize absorption effects at ppb levels. Seals are gas compatible elastomers. A heated flow path is provided. Commands are entered from the front panel and displayed on a backlit twenty-five line by eighty character liquid crystal display. Calibration sequences are stored in the internal microprocessor for recall by the keypad, optional RS-232 communications or optional status interface. Internally-stored mass flow controller calibration data improves accuracy. High capacity memory permits storage and recall of up to 200 multi-component "recipes", saving time and reducing errors. Twenty-five line by eighty character display permits viewing of data in worksheet form. Modular design allows user to add additional gas circuits later, reducing initial investment and protecting against obsolescence. Optional RS-232 Serial Data Interface permits remote operation and complete integration with a data station. SOFTWARE The Series 2014 has six primary routines accessible through "soft" keys, located immediately below their onscreen labels. Concentration Mode: User enters target output gas concentration for the span gas. The actual concentration is displayed during mixing. Flow Mode: User enters target flow rate (cc's per minute) for each component gas. Actual flow rates are displayed after mixing is initiated. The Series 2014 is available in either a standard 19” rack mount or bench top configuration. Maintain Ports: User enters the name of the component gas in the source cylinder, its concentration and the port to which it is connected. PRODUCT FEATURES AND BENEFITS Divider Mode: Allows the user to operate the instrument as a computerized ten step gas divider. Automatic Sequencer: Permits unattended automatic operation of the instrument on a programmable seven-day schedule. Purge Mode: mixing zone. Status (Optional): Allows user to remotely activate different modes of the system and also activate external devices Humidification and pressurization options are available. A purge circuit allows for nitrogen purge of the gas wetted surfaces to minimize contamination. Dynamic mixing with automatic computation of component and balance gas flow rates allows the user to formulate ppb standards and vary the concentration. Minimizes inventory of expensive, long lead time, VOC gas cylinders. Save on gas costs, cylinder rental and handling labor. K-factor computerized correction insures accurate use of all gases based on the thermal density. Purge component gas circuits and
Open the catalog to page 1SPECIFICATIONS Performance (as a percent of setpoint) * From 10 to 100% Accuracy of Full Scale Flow Concentration: ± 1.0% Flow: ± 1.0% Flow Repeatability (of setpoint) ±0.05% * Mass flow controllers are calibrated using a NIST traceable Primary Flow o o Standard, using a Reference Temperature of 0 C (32 F) and a Reference Pressure of 760mm Hg (29.92 in. Hg) Warm up time: 30 minutes Mechanical Inlets Balance: Purge: Analyte: Dimensions (w x h x d) Portable: 17” x 7” x 23.5” (43.18cm x 17.78 cm x 59.69 cm) Rack: Electrical Standard: Optional: Current: 19” x 7” x 23.5” (48.26 cm x 17.78 cm x...
Open the catalog to page 2All Environics catalogs and technical brochures
-
Series 4020
2 Pages
-
Series 2040
2 Pages
-
Series 4040
2 Pages
-
Series 2020
2 Pages
-
Series 2010
2 Pages
-
Series 3000
2 Pages
-
Series 4000
2 Pages
-
Series 2000-U
2 Pages
-
Series 2000
2 Pages
-
Series 9100
3 Pages
-
Series 6103
2 Pages
-
Series 6100
2 Pages
Archived catalogs
-
ROBD2
2 Pages