HEATED MULTI-GAS INFRARED GFC ANALYZER envea Heated Multi-Gas NDIR-GFC analyzer for emission compliance and analysis of wet sample gases in corrosive applications, including DeNOx (SCR / SNCR) and the optimization of flue gas treatment processes. ■ Designed for the measurement of wet and corrosive samples ■ Measures from 1 to 8 gas parameters, using combination of infrared spectroscopy with gas filter correlation technologies ■ Perfectly suitable for the ammonia slip detection ■ Acquisition / management of peripherals measurements (particulates, temperature, flow...) ■ Embedded HMI with Graphic LCD display and interactive menu driven firmware ■ Remote access for all analyzer functions (visualization/ maintenance / configuration / backup etc) ■ Robust design with a stainless steel tight box enclosure to withstand the harshest industrial environment ■ Optimized operation cost (low maintenance and low consumables requirement)
Open the catalog to page 1HEATED MULTI-GAS INFRARED GFC ANALYZER envea Elevating standards. For life. TECHNICAL SPECIFICATIONS MAIN OPTIONS Repeatability < 2% of the Full Scale (F.S.) Zero/Span drift < 2% of the F.S. / 30 jours Nominal power consumption 150 VA (max 450 VA) Ethernet link RJ45 port firmware update and upgrade, USB port and function configuration, backup of data, flash ■ Sampling system (probes + sampling boxes HOFI or LCPD) ■ Heated line (for standard applications max.length = 60m) ■ Pressure, temperature and velocity measurements of the sampled gas (Embedded DTP option) ■ Manual or automatic calibration...