1. Catalogs
  2. ENVEA
  3. QAL181 stack particulate monitor QAL1 certified

QAL181 stack particulate monitor QAL1 certified

QAL181 stack particulate monitor QAL1 certified

QAL181 stack particulate monitor QAL1 certified

Product catalog summary
Overview: The QAL 181 is a QAL 1 approved particulate measurement system utilizing forward-scatter technology with a minimum detection limit of less than 0.05 mg/m³. It features ProScatter™ technology for enhanced measurement accuracy by reducing cross-sensitivity to particle type and size.
Specifications:
  • Detection Limit: <0.05 mg/m³
  • Certification Range: 0-7.5 mg/m³, with supplementary ranges of 0-15, 0-100, and 0-200 mg/m³
  • Long Term Zero Drift: <0-1 mg/m³
  • Resolution: 0-1 mg/m³
  • Stack Temperature Range: -20°C to +250°C, with an option up to +500°C
  • Ambient Temperature Range: -20°C to +55°C
  • Stack/Duct Diameter: Up to 3 m
Technical Features:
  • Automatic zero and span checks for system accuracy
  • Robust design for high-temperature (up to 500°C) and hazardous zones
  • Multiple output options including TCP/IP Ethernet, RS485, RS232, and relay outputs for integration with DCS or DAHS
Sensor Specifications:
  • Material: 316 Stainless Steel / Hastelloy® for corrosion resistance
  • Enclosure Protection: IP66
  • Weight: 1.5 Kg
  • Power Requirements: 24 V DC provided by the control unit
  • Air Purge Requirements: Continuous air purge of 50 L/min
Certification:
  • Gas Zone: Zone 2, with various certificate numbers and codes for IECEx, ATEX, and UKEx
  • Dust Zone: Zone 21 and 22, with corresponding certifications
Contact Information: ENVEA PROCESS GmbH, Gutedelstraße 31, 79418 Schliengen, Germany, +49 7635 8272480
See more

Catalog excerpts

QAL181 stack particulate monitor QAL1 certified-1

QAL 181 QAL 1 APPROVED PARTICULATE MEASUREMENT SYSTEM ■ Forward-scatter technology with a minimum detection limit of <0.05 mg/m3 ■ ProScatter™ technology provides enhanced measurement due to reduced cross-sensitivity to particle type and size compared to other scatter monitors ■ Robust and rugged for challenging high-temperature 500°C stack conditions and Ex hazardous zones - Automatic zero and span checks that fully challenge the system's ability to measure forward-scattered light and satisfy daily drift checks . TCP/IP Ethernet, RS485, RS232, 4x4 - 20 mA outputs, 1x 4-20 mA input, 4x Relay outputs, 1x Relay input for increased choice of integration with your DCS or DAHS (controller specific).

 Open the catalog to page 1
QAL181 stack particulate monitor QAL1 certified-2

Elevating standards. For life. QAL 181 PARTICULATE MEASUREMENT SYSTEM TECHNICAL SPECIFICATIONS IECEx Gas Zone Certificate number Certificate code Dust Zone Certificate number Certificate code Enclosure protection rating Local output 1.5Kg standard sensor RS-485 (connection to control unit) Connection Required on Duct Hole pattern to suit DN80 PN10/PN16 or 3" 150 lb ANSI (hole ID at least 88 mm) Power Requirements Cable Entries Air Purge Requirements Dimensions 24 V DC provided by the control unit 2 x M20 cable entry glands - Dia 6-12mm cable Requires continuous air purge of 50 L/min supplied...

 Open the catalog to page 2

All ENVEA catalogs and technical brochures

  1. STACK 980

    2  Pages

  2. STACK 602

    2  Pages

  3. STACK 990

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.