Catalog excerpts
QAL1 Approved PM-CEM PROCESS & EMISSIONS MONITORING SYSTEMS SPECIFIC FEATURES: Complies with standards EN 13284-2, EN 14181 and EN 15267-3 Suitable for bag-filter applications with an Emission Limit Value (ELV) of 7.5 mg/m3³ (Incineration) and 15 mg/m3³ (Co-incineration) Automatic recording of span and zero checks to satisfy QAL3 requirements
Open the catalog to page 1TECHNOLOGY / APPLICATION SYSTEM DESCRIPTION © Dantherm Filtration Ltd. Reproduced with kind permission. The PCME QAL 991 is an approved particulate CEM (Continuous Emission Monitor) complying with monitoring standards EN 14181 and EN 13284-2. The instrument holds a QAL1 approval to the latest performance requirements specified in EN 15267-3. The PCME QAL 991 benefits from using patented ElectroDynamic ® measurement technology and is particularly suited for monitoring emissions from Waste Incineration Plant where emissions are controlled with dry scrubbing and bag-filter technology. The...
Open the catalog to page 2The PCME QAL 991 sensor provides a complete solution for measurements according to EN 14181 in its specified application range. The instrument holds a QAL1 certification range of 0-7.5 mg/ m3, meaning that it is suitable for compliance reporting from processes with daily Emission Limit Values (ELVs) as low as 5 mg/m3 (e.g. Incineration plant). The measurement and calibration features facilitate a 15-point/5-point calibration (QAL2) and permit the specification of a valid calibration range. The internal Quality Assurance features of the instrument have been designed and approved to meet the...
Open the catalog to page 3Network Modules (can be connected to Controller Network systems to provide additional Inputs and Outputs) As a progressive environmental Company, ENVEA specialises in particulate measurement for industrial processes. With a worldwide reputation for reliability, innovation and technological excellence, the Company produces under the trademark envea™ equipment for concentration and mass monitoring for regulatory, environmental and process control requirements. A dedicated team of qualified application and sales engineers is always on hand and should be consulted in the selection and usage of...
Open the catalog to page 4All ENVEA catalogs and technical brochures
-
LAS 5000XD
2 Pages
-
Amesa-M Mercury Sampler (Hg)
2 Pages
-
PCME STACK 980
4 Pages
-
PCME STACK 602
4 Pages
-
PCME STACK 710 dust monitor
4 Pages
-
PCME STACK 990
4 Pages
-
MGC101- Multi-Gas Calibrator
2 Pages
-
E-Series - AF22E SO2 monitor
2 Pages
-
SM-4 CEMS Mercury Monitor
2 Pages