Features and Benefits
  • Compliant with EN 13284-2, EN 14181, and EN 15267-3 standards.
  • Robust design that is unaffected by build-up on the sensor rod.
  • No additional services such as air purge required, reducing the cost of ownership.
  • Automatic recording of drift checks (zero and span) to meet QAL3 requirements.
  • Networking capabilities for sensor channels and multiple inputs for external devices like temperature, pressure, and O2 normalization.
Specifications
  • Measurement range: 0–100 mg/m³.
  • Certification range: 0–7.5 mg/m³, with an extended range of 0–15 mg/m³.
  • Long-term zero drift: less than 0.1 mg/m³.
  • Stack temperature range: -20 to +500°C.
  • Ambient temperature range: 20°C to +50°C.
  • Stack/Duct diameter: Ø500mm to 3m.
Sensor Specifications
  • Material: 316 Stainless Steel / PEEK/Sialon (insulator).
  • Enclosure protection rating: IP65.
  • Enclosure material: Die-cast aluminium (polyester powder coated).
  • Dimensions: 158 x 197 x 107 mm (6.2 x 7.8 x 4.2 inches), including cover lid hinges and cable glands.
  • Outputs: 1x RS-485 connection (to control unit), 1x 4-20 mA (via the control unit).
  • Power requirements: 18–24 V DC (from the control unit).
  • Cable entries: 2x M16 cable glands.
  • Air purge requirements: Air purge fitting and external supply of 5–10 L/min of dry, clean (oil-free) instrument air.
  • Dimensions: 111 x 135 x 74 mm (4.4 x 5.3 x 3 inches).
Hazardous Zone Classification
  • ATEX gas zone 2 (500°C), dust zone 22 (250°C).
  • ATEX gas/dust zones 2 and 22 (up to 500°C).
  • IECEx dust zone 2 or 20/21/22 (up to 400°C).
See more

Catalog excerpts

QAL_991_particulate_measurement_system_ENVEA-1

QAL1 APPROVED PM-CEM QAL1 approved particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial processes including baghouses and cartridge filters FEATURES AND BENEFITS Robust design unaffected by build-up on the sensor rod No additional services such as air purge required, for lower cost of ownership Networking of sensor channels and providing multiple inputs for external devices such as temperature, pressure and O2 normalisation Automatic recording of drift checks (zero and span) to satisfy QAL3 requirements

 Open the catalog to page 1
QAL_991_particulate_measurement_system_ENVEA-2

SPECIFICATIONS QAL 991 Application Conditions Measurement range Certification range 0–7.5 mg/m³, 0–15 mg/m³ (extended range) Long term zero drift Stack temperature range Ambient temperature range Stack/Duct diameter QAL 991 Sensor Specification Material 316 Stainless Steel / PEEK/Sialon (insulator) Enclosure Protection rating Enclosure material Die-cast aluminium (polyester powder coated) 158 x 197 x 107 mm (6.2 x 7.8 x 4.2”), incl. cover lid hinges and cable glands 1x RS-485 connection (to control unit) 1x 4-20 mA (via the control unit) Outputs Power Requirements 18–24 V DC (from the control...

 Open the catalog to page 2

All ENVEA catalogs and technical brochures

  1. STACK 980

    2  Pages

  2. STACK 602

    2  Pages

  3. STACK 990

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.