1. Catalogs
  2. ENVEA
  3. PM162M particulate automatic sampler : PM10, PM2.5, PM1, TSP particulates

PM162M particulate automatic sampler : PM10, PM2.5, PM1, TSP particulates

PM162M particulate automatic sampler : PM10, PM2.5, PM1, TSP particulates

PM162M particulate automatic sampler : PM10, PM2.5, PM1, TSP particulates

Product catalog summary
Overview: The PM162M is an automatic, low volume particulate sampler designed for air quality monitoring. It complies with EU CEN recommendations and is EN 12341 certified for PM2.5 sampling and measurement. The device is used to collect particulate matter from ambient air for gravimetric weighing and potential physicochemical analysis.
Specifications: The PM162M features a filter holder with a capacity of 22 filters, allowing for up to 3 weeks of autonomous sampling. It offers a true volumetric air flow control with sensors for atmospheric temperature and pressure. The sampler includes a temperature-regulated sampling tube to prevent evaporative losses of semi-volatile particulates. It supports user-selectable sampling durations and has a programmable rest time function.
Technical Specifications: The sampler operates at a flow rate of 1 m3/h or 2.3 m3/h, with a filter diameter of 47mm. It is powered by a 220 V - 50 Hz supply and consumes a maximum of 360 VA. The device is designed to operate within a temperature range of +5°C to +40°C.
Options: The PM162M offers various options including a temperature-regulated sampling tube of different lengths, a conditioned or ventilated cabinet for outdoor installation, memory extension, and an external opto-isolated I/O interface. It also provides a special version with a 70 filters capacity and a choice of TSP, PM10, PM2.5, or PM1 sampling inlets.
Applications: The sampler is suitable for sequential sampling through PM10, PM2.5, PM1, and TSP size selective inlets. It is used for heavy metals sampling in ambient air, indoor air sampling, field surveys before setting up continuous analyzers, and follow-up of specific pollutants.
Principle of Operation: The PM162M operates by collecting particles with aerodynamic diameters of approximately 100 μm or less. The sampled air is passed through a thermo-controlled line to avoid condensation and mass losses due to volatile compounds. The system ensures accurate sampling by maintaining the sampling line at a temperature 5°C above atmospheric temperature when relative humidity is high.
See more

Catalog excerpts

PM162M particulate automatic sampler : PM10, PM2.5, PM1, TSP particulates-1

Automatic, Low Volume, Particulate Sampler AIR QUALITY MONITORING SYSTEMS PM162M is a sequential automatic sampling device for particulate matter in the ambient air. The particles are sampled at constant flow rate (1 m3/h or 2.3 m3/h) and collected on filters for gravimetric weighing and possible physicochemical laboratory analysis. SPECIFIC FEATURES: T he PM162M is equiped with a filter holder carrying 22 filters capacity, which corresponds to 3 weeks of normal, 24 hours samplings, fully autonomous T rue volumetric air flow control with atmospheric temperature and pressure sensors to avoid artifacts in the size fractionating inlet T emperature-regulated sampling tube to prevent artefacts on the filter (evaporative losses of semivolatile particulates...) P rogrammable Rest Time function: enables a rest time (without sampling) between the sampling cycles U ser-selectable starting time mode (immediate, delayed, hourly synchronization) L CD graphic display and interactive user-friendly multi-task software H ighly reliable components and robust design allow the PM162M very low maintenance. O ption: Very high size filter holder (max 70 filters) allowing up to 10 weeks of sampling MAIN APPLICATIONS: Sequential sampling through PM10, PM2.5, PM1 and TSP size selective inlets Heavy metals sampling in ambiant air Indoor air sampling Field survey before setting up of a continuous analyzer Follow-up of a specific pollutant... COMPLIANCE WITH: E U CEN recommendations for PM2.5 sampling & measurement N 12341 certified (LECES, n°RC/L 9826) E Example: mural version of the sampler, installed in a fixed, outdoor station PM162M rack version charging of the filter holder

 Open the catalog to page 1
PM162M particulate automatic sampler : PM10, PM2.5, PM1, TSP particulates-2

Automatic, Low Volume Particulate Sampler PM162M Sample PRINCIPLE OF OPERATION: The PM162M sampler is compliant with the EN12341 standard and can be used to determine the average ambient particulate concentration over the sampling period. The collected material is weighed to determine concentration and can be subsequently chemically analyzed. Atm. temp. & RH sensors Atm. Pressure sensor Pressure senssors Its fine dust sampling system is designed to collect particles with aerodynamic diameters of approximately 100 μm or less to be deposited uniformly across the surface of a filter located downstream...

 Open the catalog to page 2