Overview: The MGC101 Multi-Gas Calibrator is designed for air quality monitoring systems, meeting all U.S. EPA requirements. It performs automatic zero, precision, span, and multi-point calibrations using various gases such as NO, NO2, SO2, CO, O3, and hydrocarbons.
Specific Features:
  • User-friendly software with plain language prompts reduces training time and errors.
  • Automatic calculation of dilution and span gas flows based on commanded concentration.
  • Internally-stored mass flow controller calibration data enhances accuracy and simplifies recalibration.
  • Simultaneous connection from 1 to 4 gas cylinders, with an option for 5.
  • Easy programming with keyboard and pop-up menu, and automatic calibration sequences.
  • LCD screen with 4 lines and 20 characters.
Main Applications:
  • Air quality monitoring stations and mobile laboratories for manual, automatic, or remote calibration.
  • Used as a reference calibrator in central stations.
  • Testing of analyzers through automatic zero, precision, span, multi-point calibration, and gas phase titration (GPT).
Operating Principle: The MGC101 includes thermal mass flow controllers, an ozone generation module, a mixing zone, a reaction chamber for gas phase titration, and control electronics. It is calibrated to a NIST traceable primary standard, with data stored in non-volatile memory. The ozone generator is factory calibrated using a NIST traceable ozone standard.
Technical Specifications:
  • Flow accuracy: ± 1% of full scale.
  • Flow: ± 0.1% of full scale.
  • Dilution ratio: 1/12 to 1/900 in dilution mode, 1/56 to 1/500 in TPG mode.
  • Ozone production: 0.02 ppb to 0.5 ppm, with an option for 0.05 ppb to 1 ppm at 10 l/m.
  • Pre-heating time: 30 minutes.
  • Response time: 2 minutes for 1% accuracy.
  • Operating pressure: 1.72 bars recommended, 1.38 bar minimum, 2.07 bars maximum.
  • Power supply: 230 V, 50 Hz or 115 V, 60 Hz, with 250 VA consumption.
  • Operating temperature: 0°C to +50°C.
Main Options:
  • Built-in permeation benches for certified permeation tubes.
  • Additional dilution ratios upon request.
  • Third mass flow controller.
  • UV Photometer.
  • Solenoid valve on the outlet.
  • Additional gas inlet.
Standard Functions:
  • Blend: Automatically calculates and delivers specified concentrations.
  • Ozone generation: Allows precise and stable ozone generation.
  • Gas Phase Titration (GPT): Based on the reaction NO + O3 → NO2 + O2, using the excess nitric oxide Transfer Standard Procedure (GPT-NO).
  • Manual: Allows manual command of flow rates.
  • Display: Monitors flow rates and provides ozone oven block temperature.
  • RDM calibration: Multi-point calibration.
  • Ozone generator calibration: Performed using 7 to 11 points for improved linearity.
See more

Catalog excerpts

MGC101- Multi-Gas Calibrator-1

Multi-Gas Calibrator AIR QUALITY MONITORING SYSTEMS The MGC101 system automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases of interest. It meets all U.S. environmental protection agency requirements. SPECIFIC FEATURES: User-friendly interactive software with plain language prompts is simple to use, reducing technician training time and virtually eliminating error Automatic calculation of dilution and span gas flows, based on commanded concentration, eliminates the need for any manual computation and allows rapid transition from point to point Internally-stored mass flow controller calibration data improves accuracy (factor of ten) and simplifies field recalibration Simultaneous connection from 1 to 4 gas cylinders (option for 5) Easy programming with keyboard and pop-up menu A utomatic calibration sequences programmation LCD screen (4 lines / 20 characters) Multi-gas calibrator for ambient air gas analyzer calibration MAIN APPLICATIONS: Air quality monitoring stations and mobile laboratories for manual, automatic or remote calibration Used as a reference calibrator in central station Test of analyzers: Automatic zero, precision, span, multi-point calibration and gas phase titration (GPT)

 Open the catalog to page 1
MGC101- Multi-Gas Calibrator-2

AIR QUALITY MONITORING SYSTEMS The MGC101 consists of a single chassis supporting 2 thermal mass flow controllers, an ozone generation module, a mixing zone, a reaction chamber for gas phase titration, and control electronics. The mass flow controllers are calibrated to a NIST (National Institute of Standards and Technology) traceable primary standard. The calibration data consists of a comparison of desired versus actual flow over the full dynamic range of the instrument with linear interpolation between points. Calibration data is stored in non-volatile memory and may be updated by the user...