AQMS e-Series gas analyzers - ecodesigned pollution monitors
12Pages

{{requestButtons}}

Catalog excerpts

AQMS e-Series gas analyzers - ecodesigned pollution monitors - 1

energy saving efficiency engineered economic essential Criteria Pollutants Analyzers Outstanding features, amazing innovations!

Open the catalog to page 1
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 2

Unique Sustainable EcodesignThe e-Series of analyzers has been designed with a special consideration to the environmental impacts of the product during its whole lifecycle. The measurement modules of the e-Series are fitted in closed cell expanded polypropylene foam (EPP*) that has outstanding cushioning properties, high strength-to-weight ratio and efficient thermal and electrical insulation. Components such as tubes, cables, circuit boards or fans are tightly held into various channels and cavities that are moulded into the EPP chassis. This simplifies the assembly process and also...

Open the catalog to page 2
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 3

The exclusive “inside the box” foam modular concept makes the product more robust, power saving, quieter in operation, simpler to service and eco-friendly. Power saving Sustainable Eco Design Recyclability EPP foam concept Screen saving ROHS compliant Low Carbon footprint Lightweight Join our vision to reduce pollution, limit the waste and protect the environment Typically, air quality monitors equipped with individual screens, are installed in mobile or fixed monitoring stations with generally a computer for data acquisition and processing software such as the XR® from ENVEA. Excepting...

Open the catalog to page 3
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 4

Smart, connected instruments The complete range of e-Series integrates an embedded web server featuring intuitive navigation by pictograms and offering quick and easy access to the analyzer. Secured (various level of passwords), modern, simple, fast and accessible through any browser, the ENVEA ConnectTM user interface allows remote, simultaneous multichannel viewing and control of the monitor from any PC, tablet or smartphone. U ser-friendly design interface: one click to perform zero, span or calibrations using gas cylinders Efficient Easy to operate A utomatic recognition of plugged...

Open the catalog to page 4
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 5

Service Assistant Inside Engineered with breakthrough technologies, the e-Series achieve a previously unreachable level of autonomy: it also integrates self diagnosis and a high level of self-operation. Each analyzer is self monitored continuously for performance and fault control: it detects early signs of trouble, identifies the service needed and even guides the service operations! Help on board Smart analyzer Remote service A nticipates failures: each analyzer records the states of health parameters for immediate expert advice on site or remotely W hen on-site maintenance is required,...

Open the catalog to page 5
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 6

All you need is in your hand Standalone, in a Mobile Laboratory, Fixed Shelter, Micro-monitoring Station Trustworthy communication (password protected) ENVEA ConnectTM Direct, local access (integrated Wi-Fi) Remote access (LAN connections)

Open the catalog to page 6
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 7

animated synoptics measurements in real time guide step by step repair / maintenance required automatic recognition of optional devices and spares automatic drivers’ download filter changing automatic / programmable response time zero / zero ref span / span check programmable span / zero data download software upgrade system backup customization State of health reports

Open the catalog to page 7
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 8

UV photometry Ozone analyzer The O342e combines patented optical technology with decades of expertise to ensure you get the best ozone monitoring results available on the market, quickly, ecologically and reliably! Applied to ozone measurement, the UV Direct Absorption (UV-DA) technique, based on the UV photometry principle, consists in measuring the UV light absorption by ozone molecules. The ozone concentration is deduced by applying a ratio between two different UV signals. One of the signals is determined when the air sampling passes through a new high quality ozone scrubber used as a...

Open the catalog to page 8
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 9

UV Fluorescent SO2 analyzer AF22e The UV Fluorescence Technique consists in detecting the fluorescent radiation emitted by SO2 molecules after reaching a temporary electronic state. A photodiode measures the ultraviolet radiation generated by the UV lamp. This measurement is used during signal processing in order to compensate for any variation of the UV energy. Molecules restore a specific fluorescence in the ultraviolet: this fluorescence is visualized by the PM tube placed near the reaction chamber. ^Return to fundamental State : SO2* => SO2 + hv' (hv' at A =350 nm) The AF22e analyzer...

Open the catalog to page 9
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 10

Non dispersive Infra Red CO/CO2 analyzer CO12e The CO sample concentration is determined by measuring the quantity of infrared light the sample gas absorbs as it flows through a multi-reflection chamber. As absorption spectrum is not continuous, a gas filter, "correlation wheel”, is used in conjunction with the optical filter, it allows highly selective sample gas measurement by eliminating gas interference with a very-close CO absorption spectra. CO12e combines state-of-the-art components and powerful design technology for reduced and easy maintenance: > New correlation wheel equipped with...

Open the catalog to page 10
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 11

Chemiluminescent NO-NOx & NO2 analyzer AC32e The AC32e utilizes the principle of chemiluminescence for automatically analyzing the NO - NOx and NO2 concentration within a gaseous sample. The reaction between NO and O3 (ozone) emits light. This reaction is the basis for the CLD in which the photons produced are detected by a photo multiplier tube (PMT). The CLD output voltage is proportional to NO concentration. The light-producing reaction is very rapid so a very rapid response instrument is suitable for good measurements. The new AC32e analyzer combines 30 years of experience with its...

Open the catalog to page 11
AQMS e-Series gas analyzers - ecodesigned pollution monitors - 12

Corporation offices Distribution network ENVEA’s support capability extends throughout the world and has proven to provide efficient, and proactive services to our global customer base. We know the importance to our customers of having instruments serviced at their sites to reduce downtime and increase instrument availability. The Group offers its expertise to customers and partners through a comprehensive range of technical support services, training packages and a ‘knowledge transfer’ approach in a spirit of a partnership. Our commitment is to help you meet your specific monitoring...

Open the catalog to page 12

All ENVEA catalogs and technical brochures

  1. LAS 5000XD

    2 Pages