ENTES is a technology brand, developing solutions Wherever Energy Is... ENTES is an European technology company that works ardently since 1980 to manage the energy where energy is valuable and overcosting. As one of the leading enterprises in shaping the way of conducting business, ENTES transforms energy into a manageable concept so that business can be conducted at the lowest cost, thus providing new economical opportunities. Based on its own resources, ENTES takes advantages of qualified brain power and hard work with an aim of being pragmatic and also open to technological developments in...
Open the catalog to page 2Sister Companies SISTER COMPANIES IN TURKEY NETA ELEKTRONİK CİHAZLAR SAN.TİC.A.S. : Satellite Systems Line of Business : http://www.neta.com.tr Web ENTES APART HOTEL Line of Business Web : Tourism : http://www.entesapart.com GENTA A.S. Line of Business Web : Marble & Granite Marketing and Contracting : http://www.gentagranit.com ENTPA A.S Line of Business Web : Electronic Security, Access, Video Doorphone System Distribution : http://www.entpa.com.tr SISTER COMPANIES ABROAD ENTES GREECE Line of Business E-mail : Marketing ENTES Products in Greece. : [email protected] ENTES GERMANY Line of Business...
Open the catalog to page 3ENTES R&D Team, composed from nearly 50 employees, provides customer oriented solutions by designing devices at international standards and using state-of-the-art technology where they also develop software that are compatible with these devices. All products undergo 10 different testing phases including functionality, standard compliance and IEC EN 60255 model tests. ENTES products complying with international standards have acquired various certificates including ISO 9001-2008, CE, TSE, KEMA CB, KEMA-KEUR, CSA-US, UL, MID B+D and GOST-R. The materials and components used in production are controlled...
Open the catalog to page 4Entes Quality Is Under These Labels POWER QUALITY AND ENERGY ELECTRICAL MEASUREMENT POWER FACTOR CORRECTION REMOTE MONITORING PROTECTION & CONTROL
Open the catalog to page 5Power Quality and Energy MPR-1 Series Network Analyzers MPR-2 Series Network Analyzers MPR-3 Series Network Analyzers MPR-4 Series Network Analyzers MPR-6 Series Network Analyzers MPR-5 and EPM-07 Series Network Analyzers EPR-04 and ES Series Power and Energymeters Electrical Measurement EPM-04 - EPM-06 - EVM-05 Series Multimeters EPM Series Ammeters EVM Series Voltmeters EFC-3 Frequencymeter / ECR-3 Cosjmeter TA Series Current Transducers / TV Series Voltage Transducers DC Ammeters / DC Voltmeters Power Factor Correction RG Series Power Factor Controllers ENT.C Series Capacitors ENT.ERS Series...
Open the catalog to page 6Product Index
Open the catalog to page 7Power Quality and Energy The products in ‘‘ENTES Power Quality and Energy’’ group are designed to measure various electrical parameters. With their communication features all measurements can be tracked from a single monitoring center. Energy quality and efficiency analysis can be performed with network analyzers in electrical distribution/transmission systems, such as industrial facilities and buildings. Network Analyzers MPR-1 Series MPR-2 Series MPR-3 Series MPR-4 Series MPR-5 Series MPR-6 Series EPM-07 Series Power and Energy Meters EPR-04 Series ES Series
Open the catalog to page 8MPR-1 Series Network Analyzers MPR-1 Series DIN type network analyzers have been designed for the purpose of measurement of electrical parameters at machines and panels. By means of its design without a screen, it is a cost effective measurement device series for energy monitoring software. ® Remote Monitoring Software: With the energy management software developed by ENTES, energy consumption and quality can be monitored in real time by reading the values measured by devices. As a result, comprehensive energy monitoring and data storage is provided. With the analysis of stored data, improvements...
Open the catalog to page 9Power Quality and Energy Network Analyzers MPR-1 Series MEASURED PARAMETERS Phase - Neutral Voltages (VLN) Active Energy Import (kWh or MWh) Phase - Phase Voltages (VLL) Active Energy Export (kWh or MWh) Average Phase-Neutral Voltage Reactive Energy Capacitive (kVArh or MVArh) Average Phase-Phase Voltage Total Active Power (åP) Reactive Energy Inductive (kVArh or MVArh) Total Reactive Power (åQ) Apparent Energy (kVAh or MVAh) Total Apparent Power (åS) Total Harmonic Distortion for Voltage (THD-V) Total Harmonic Distortion for Current (THD-I) 1-51st Individual Voltage Harmonics Voltage / Current...
Open the catalog to page 10Power Quality and Energy Network Analyzers MPR-1 Series SPECIFICATIONS MPR-15S-22 ENCLOSURE DIN4 Rail Mounting, 24 Pcs/Box Terminals = IP20, Enclosure Protection Class = IP 40 LED indicator for Communication, Power and I/O Dimensions Protection Class Indicator MEASUREMENTS Voltage Measurement Range Measurement Range with Transformer Accuracy Input Impedance Burden (Input Load) Current Rated Current Minimum Current Measurement Range In : 5A / 1A 5 mA 50 mA - 5,5 A Accuracy : %0.5 ± 1 Digit 50 mA -10000 A <1 VA 1,2 In continuous 10xIn Measurement Range with CT Burden Overload Current Short Time...
Open the catalog to page 11Power Quality and Energy Network Analyzers (LED) MPR-2 Series MPR-2 Series DIN rail type Network Analyzers MPR-2 Series DIN Type network analyzers have been designed for detailed measurement and analysis of electrical parameters. With their communication features all measurements can be tracked from a single monitoring center. MPR-2 series can detect the status and allow the control of devices (breakers, switches, contactors etc.) in the field via their digital inputs and outputs. ® Event Recording Run/On Hour Pulse Counter Current/Voltage Unbalances Relay Output Analog Output Digital Input Digital...
Open the catalog to page 12MPR-2 Series MEASURED PARAMETERS Phase - Neutral Voltages (VLN) Active Energy Import (kWh or MWh) Phase - Phase Voltages (VLL) Active Energy Export (kWh or MWh) Reactive Energy Capacitive (kVArh or MVArh) Total Active Power (åP) Reactive Energy Inductive (kVArh or MVArh) Total Reactive Power (åQ) Apparent Energy (kVAh or MVAh) Total Apparent Power (åS) Total Harmonic Distortion for Voltage (THD-V) Total Harmonic Distortion for Current (THD-I) Voltage / Current Unbalances 1-51st Individual Voltage Harmonics 1-51st Individual Current Harmonics Connection Diagram DIN-4 - MPR-2 Series The connection...
Open the catalog to page 132 Pages
2 Pages
2 Pages
6 Pages
4 Pages
6 Pages
4 Pages