Catalog excerpts
ELEKTRONİC CONTROL SYSTEMS DESCRIPTION MSU 2.0 manual genset control unit provides the functions, required in manual control applications of gensets. MSU 2.0 runs and stops generator manually, protect it against failures and displays necessary datas on front panel. It also provide generator contactor function. The module offers a very cost effective and space saving solutions as it is able to display all the parametres which are essential for the basic gen-set control.The module has 2 operation modes.Stop,Start operation modes can be chosen via the push-buttons mounted on the front panel.While the module is in Stop mode,if the menu button is pressed ,the 29 parameter settings, which are used for controlling the generator,can be adjusted.So the module can be adapted to all the generator without the need of any other unit or module. OPERATION PRINCIPLES Monitoring and Indicators: L1-N generator voltage Generator frequency By pressing the menu button in start mode,parameters can be displayed on the unit. 8 failure indicators on the front panel Operation modes: Reset The reset button is used to cancel the alarm and failures. MANUAL START UNIT The Start button is used for operating the generator by using the parameters settings which are adjusted before.When the generator operates within the limits adjusted before ,the load is transferred to the generator.By pressing stop button, the generator is stopped automatically by using the parameter settings.In case of a failure while operating, the unit will stop the generator automatically. By pressing stop button, the generator is stopped automatically by using the parameter settings.If the load output is energised, the generator is operated off load until the cooling time expires. 10006 Sok. No:64 Atatürk Organize Sanayi Bölgesi Çiğli - İZMİR / TÜRKİYE Tel: +90 232 376 78 06 (Pbx.) Faks:+90 232 376 77 92 E-Mail: info@enkoelekt
Open the catalog to page 1ELEKTRONİC CONTROL SYSTEMS Micro-processor based design Automatic engine starting and stopping Automatic load transfer Configurable via front panel Automatic shut down on fault condition Operate with cranking dropouts Preheat,auto ready and engine start outputs Stop/fuel solenoid selection Generator phase true RMS voltage measuring and monitoring Generator frequency measuring and monitoring Digitally adjustable low&high generator voltage limits Digitally adjustable generator start timings Digitally adjustable generator overspeed /underspeed limits Digitally adjustable generator stop timings...
Open the catalog to page 2