Product catalog summary
Overview: The document describes the ATS1.1 and ATS1.0 Load Transfer Control Switches, which manage the transfer of electrical loads between mains and generator bus-bars, prioritizing mains. These switches are designed for independent control of load and generator, ensuring reliable power supply.
Main Features:
  • True RMS voltage measurements on both bus-bars.
  • Wide operating temperature range from -35°C to +70°C.
  • Mains frequency monitoring with conditional load transfer.
  • Full configuration available on controller I/O ports.
  • IP52 protection class for front panel.
  • Remote start and stop operation interface.
  • Engine cool-down timer for generator interface.
Technical Specifications:
  • DC power supply: 9-35Vdc with 1W maximum power dissipation.
  • Operating temperature: -35°C to +70°C.
  • Relative humidity: 20% to 99% non-condensing.
  • AC voltage measurement: 20Vac to 500Vac phase to phase.
  • Frequency measurement: 1.0Hz to 99.9Hz with ±0.1Hz accuracy.
  • Measurement accuracy: Phase voltages ±2% of scale, Frequency ±0.1Hz.
  • System outputs: Remote start/stop, MCB, GCB, and AUX with specified current and voltage ratings.
  • Weight: 160 grams.
  • Mounting: 72mm x 72mm front panel.
Design and Construction: The controllers are housed in plastic enclosures made of NORYL (PPO) with added fiber for high temperature resistance and mechanical stability. The front panel is designed with embossed Lexan for easy control and clear digital readings, complying with IP52 protection standards. The internal construction is optimized for vibration resistance and high humidity environments.
Functionality: Both ATS1.1 and ATS1.0 monitor mains bus-bar voltages and transfer loads if voltage limits are exceeded. ATS1.1 includes additional auxiliary inputs and outputs for enhanced control, configurable via the device menu. The units support generator testing with or without load transfer and display voltage values in True RMS for accuracy.
Application and Configuration: The units are suitable for applications requiring load control based on bus-bar availability. ATS1.1 offers additional auxiliary ports for specific applications, with configurable I/O ports for customer-specific needs. A two-stage password control protects system settings, and auxiliary outputs are dry contact relay type for flexible connectivity.
See more

Catalog excerpts

Automatic Load Transfer Controllers ATS1.1 /1.0-1

Automatic Load Transfer Controllers ATS1.1 /1.0 ENKO Electronic Control Systems - IZMIR / TURKIYE Automatic Load Transfer Switches: ATS1.1 and ATS1.0 ATS1.1 and ATS1.0 are dedicated ATS1.1 and ATS1.0 are both Load Transfer Control Switches, which Load Transfer Control switches, monitors the Mains Bus-Bar voltages and transfer the load if the voltage limits fall beyond required tolerances. These units can be used which allow independent control of with any two voltage bus-bars, where the load is required to be controlled according to their availability. All three phase voltages are monitored on the mains bus-bar side and each phase can have independent upper and lower voltage limits. ATS1.0 is a basic Transfer Control Switch, where only the basic control functions are required with no auxiliary input or output functions. ATS1.1 is on the other hand, designed with 2 auxiliary outputs and 3 auxiliary inputs. These i/o ports can be configured from the device menu for peripheral device control. The units allow the user to crank the generator on for testing or periodical maintenance. This test function can be executed with or without load transfer, allowing testing for the transfer switch at the same time. Normal system operation is maintained in the Automatic mode. During operation, mains or generator phase voltage can both be monitored on the controller display, hence avoiding extra AC voltmeters to be used on the panel. All voltage values are displayed in True RMS values with high reading accuracy. All unit parameters can be adjusted from the device configuration Main features: 3 phase mains voltage single phase generator voltage monitoring and measurement 3 digit LED display for voltage readouts and parameter displaying 5 configurable i/o ports for engine and system controls Full LED indicators for busbar status condition indication AUTOMATIC, TEST on-load and TEST off-load operation modes Full digital calibration of all analog measuring variables Load transfer function on Mains Frequency monitoring load from either Mains or Generator menu and all program parameter values can be seen on the controller display. The units can also be programmed to control the engine cool- Small mechanical outline for minimal control applications bus-bars, whichever is available, with mains bus-bar priority. down function, hence allowing simple engine starter units to be used with small capacity generator sets. Plug type terminals on the rear panel load and generator, feeding the SIMULTANEOUS MONITORING OF MAINS AND GENERATOR BUSBARS CONFIGURABLE I/O PORTS FOR CUSTOMER SPECIFIC APPLICATIONS Additional features: MAINS FREQUENCY MONITORING TRUE RMS VOLTAGE MEASUREMENTS ON BOTH BUSBARS Operating temperature: MAINS FREQUENCY MONITORING AND CONDITIONAL LOAD TRANSFER FULL CONFIGURATION ON CONTROLLER I/O PORTS Measurement accuracy: Phase voltages: ±2% of scale, Frequency: ±0.1Hz System Outputs: LOAD TRNASFER CONDITIONAL ON MAINS PHASE STATUS (LOCK-ON MAINS BUS BAR) Frequency measurement: IP52 PROTECTION CLASS (front panel protection) REMOTE START AND STOP Relative humidity: IP52 (front panel protection) Mains side (3 phase voltage) Protection class: MAINS TRANSFORMER REMOTE START/STOP SIGNAL 9-35Vdc @ 1W maximum power dissipation (12Vdc, relays off) WIDE OPERATING TEMP. RANGE (-35°C to +70°C) Technical specifications: FULL ENGINE CONTROL OPERATION INTERFACE ENGINE COOL-DOWN TIMER FOR SIMPLE GENERATOR ENGINE START RELAY

 Open the catalog to page 1
Automatic Load Transfer Controllers ATS1.1 /1.0-2

APPLICATION CONNECTION DIAGRAM LOAD UTILITY DIESEL ENGINE shown above for both models. plastic housings, designed according Mechanical dimensions to DIN norms. Mechanical dimen- ports for more specific Remote start output Typical connection diagram is Emergency Stop sions are shown in the drawing. configurable through the system Plastic housing is made of NORYL (PPO) with added fiber, which provides high temperature resistance Two stage password control and good mechanical stability. The protects system settings against inexperienced users. The front panel is designed to com- contact relay type...

 Open the catalog to page 2

All ENKO Elektronik Kontrol Sistemleri San. ve Tic. Ltd. Sti. catalogs and technical brochures

  1. CCS 4.2

    2  Pages

  2. ESR 3.1

    2  Pages

  3. ESR1.1

    2  Pages

  4. ATS2.0

    2  Pages

  5. MSU4.2

    2  Pages

  6. MSU3.4L

    2  Pages

  7. MSU 2.0

    2  Pages

  8. AMF5.2

    2  Pages

  9. AMF5.1

    2  Pages

  10. AMF4.2

    2  Pages

  11. AMF3.4L

    2  Pages

  12. AMF3.4

    2  Pages

  13. AMF3.2

    2  Pages

  14. AMF3.1

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.