ATS2.0

ATS2.0

ATS2.0

Product catalog summary
Overview: The ATS2.0 is a versatile automatic load transfer switch designed for demanding applications. It directly controls pulse-type breaker modules and is ideal for bus-bar control and load management. It features enhanced user-selectable functions and monitors both generator and mains voltages across three phases.
Main Features:
  • True RMS voltage measurements on both bus-bars.
  • Wide operating temperature range from -35°C to +70°C.
  • Mains frequency monitoring and conditional load transfer.
  • Full configuration on controller I/O ports.
  • IP52 protection class for front panel.
  • Remote start and stop operation interface.
  • Engine cool-down timer for generator interface.
Technical Specifications:
  • DC power supply: 9-35Vdc with 1W maximum power dissipation.
  • Operating temperature: -35°C to +70°C.
  • Relative humidity: 20% to 99% non-condensing.
  • AC voltage measurement: 20Vac to 500Vac phase to phase.
  • Frequency measurement: 1.0Hz to 99.9Hz with ±0.1Hz accuracy.
  • Measurement accuracy: Phase voltages ±2% of scale, Frequency ±0.1Hz.
  • System outputs: Remote start/stop and MCB, GCB at 10A/250Vac, AUX at 6A/250Vac.
  • Weight: 180 grams.
  • Mounting: 96mm x 96mm front panel.
Functional Capabilities: The ATS2.0 allows for simultaneous monitoring of mains and generator bus-bars, configurable I/O ports for specific applications, and mains frequency monitoring. It can control MCB and GCB contactors and compact circuit breakers directly from its ports. The module supports generator testing and maintenance, with automatic load transfer in case of mains voltage failure.
Design and Construction: The ATS2.0 features a plastic housing made of NORYL with added fiber for high temperature resistance and mechanical stability. The front panel complies with IP52 protection class and uses embossed Lexan for easy control and clear digital readings. The inner construction is resistant to vibration and high humidity environments.
Application and Configuration: The ATS2.0 includes a typical connection diagram and configurable ports through the system menu. It features two-stage password control for system settings protection and separate control output signals for circuit breaker functions. Auxiliary outputs are dry contact relay type switches, and the unit supports various alarm interface algorithms for easy peripheral device integration.
See more

Catalog excerpts

ATS2.0-1

Automatic Load Transfer Controllers ATS2.0 ENKO Electronic Control Systems - IZMIR / TURKIYE Automatic Load Transfer Switch ATS2.0 is a very versatile load ATS2.0 is a full Automatic Load Transfer Control Switch, which moni- transfer switch, intended to be used in most demanding applications. tors 3ph Mains Bus-Bar voltages and transfer the load, if any or all Can control pulse type breaker monitors Mains frequency for the same action. These units can be modules directly from its output used with any two voltage bus-bars, where the load is required to be controlled according to their availability. The control module also phase voltages go out of their respective set limits. The controller also monitors all three phases of the Generator bus-bar and take action accordingly. ATS2.0 is designed with highly functional capabilities where the user can interface with most demanding applications. The module can control MCB and GCB contactors as well as compact circuit breakers direct from its ports, where two independent signals are required for switching the breaker on and off. The module allows the user to start the generator for testing or periodical maintenance. While the generator is running, the load can be transferred between mains and generator bus-bars, using the switches on the front panel. If, during this phase, the mains voltage fails, the unit automatically switches to “Auto” mode and connects the Its built-in features make ATS2.0 a load to Generator output. perfect device for bus-bar control During operation, mains or generator phase voltages or frequency can and load management module, integrated with enhanced user both be displayed on the front panel, hence avoiding extra AC voltmeters to be used on the panel. All voltage values are displayed in True selectable functions. All unit parameters can be adjusted from the device configuration menu and all program parameter values can be seen on the controller display. The units can also be programmed to control the engine cool- grammed for many specific func- down function, hence allowing simple engine starter units to be used with small capacity generator sets. CONFIGURABLE I/O PORTS FOR CUSTOMER SPECIFIC APPLICATIONS  3 digit LED display for voltage readouts and parameter displaying  5 configurable i/o ports for engine and system controls  Full LED indicators for busbar status condition indication  AUTOMATIC, TEST on-load and TEST off-load operation modes  Switching of MCB and GCB contactors manually with the front panel push buttons  Full digital calibration of all analog measuring variables MAINS FREQUENCY MONITORING  Small mechanical outline for minimal control applications  Plug type terminals on the rear panel SIMULTANEOUS MONITORING OF MAINS AND GENERATOR BUSBARS  3 phase Mains and Generator voltage measurement and monitoring  Load transfer function on Mains Frequency monitoring RMS values with high reading accuracy. Both Generator and Mains voltages are monitored in 3 phases and Main features: Additional features: TRUE RMS VOLTAGE MEASUREMENTS ON BOTH BUSBARS 9-35Vdc @ 1W maximum power dissipation (12Vdc, relays off) Operating temperature: MAINS FREQUENCY MONITORING AND CONDITIONAL LOAD TRANSFER FULL CONFIGURATION ON CONTROLLER I/O PORTS Frequency measurement: LOAD TRNASFER CONDITIONAL ON MAINS PHASE STATUS (LOCK-ON MAINS BUS BAR) IP52 PROTECTION CLASS (front panel protection) REMOTE START AND STOP Relative humidity: MAINS TRANSFORMER 3 inputs, fully configurable 2 change-over relay output contacts and 2 breaker contacts Measurement accuracy: Phase voltages: ±2% of scale, Frequency: ±0.1Hz System Outputs: REMOTE START/STOP SIGNAL WIDE OPERATING TEMP. RANGE (-35°C to +70°C) Technical specifications: Protection class: IP52 (front panel protection) Mains side (3 phase voltage) Generator side (3 phase voltage) FULL ENGINE CONTROL OPERATION INTERFACE ENGINE COOL-DOWN TIMER FOR SIMPLE GENERA

 Open the catalog to page 1
ATS2.0-2

APPLICATION CONNECTION DIAGRAM LOAD UTILITY DIESEL ENGINE module. All ports are configurable Mechanical dimensions Two stage password control norms. Mechanical dimensions are through the system menu. Configurable output 2 (default remmote stop) ATS2.0 controller has plastic hous- shown above for ATS2.0 control Configurable output 1 (Default Remote start) Typical connection diagram is Configurable output 4 (default generator fault) Configurable output 3 (default mains fault) Emergency Stop Plastic housing is made of NORYL protects system settings against inexperienced users. (PPO) with added fiber,...

 Open the catalog to page 2

All ENKO Elektronik Kontrol Sistemleri San. ve Tic. Ltd. Sti. catalogs and technical brochures

  1. CCS 4.2

    2  Pages

  2. ESR 3.1

    2  Pages

  3. ESR1.1

    2  Pages

  4. MSU4.2

    2  Pages

  5. MSU3.4L

    2  Pages

  6. MSU 2.0

    2  Pages

  7. AMF5.2

    2  Pages

  8. AMF5.1

    2  Pages

  9. AMF4.2

    2  Pages

  10. AMF3.4L

    2  Pages

  11. AMF3.4

    2  Pages

  12. AMF3.2

    2  Pages

  13. AMF3.1

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.