AMF3.4L - 1

Mains Failure Controllers (With LCD Graphic Display) ENKO Electronic Control Systems - IZMIR / TURKIYE Automatic Mains Failure Controller for Gen -Sets AMF3.4L is designed with high AMF3.4L is a full Automatic Mains Failure unit intended to be used for demanding applications in mind. Mains and Gen-Set control, where high process power is required. The controller can be used with single or three phase mains and gen- The unit is equipped with LCD Graphic display for simple and efficient user interface. User can erator systems. select the display language. RMS and also 3 phase generator load current is measured. Phase sequence and Reverse Power Protection is provided for the Generator. 3 phase mains and 3 phase generator voltages are measured in true User can program any of the auxiliary i/o ports for custom applications. The menu offers extensive control for each i/o and all the parameters can be configured via PC, using the ENKO PRO-Link config- Main features: 3 ph mains voltage, 3 ph generator voltage and current measurement Graphical LCD display with white LED backlight 13 configurable i/o ports for engine and system controls uration program. All the parameters can also be configured from the front panel controls. SMS messages can be sent, using optional GSM Measurement of active/ reactive load power and PF interface module. The unit can be programmed from remote distance. Full LED indicators for alarm and status conditions Built-in graphical display offers easy reading of all the parameters during run time and programming. There are 3 analog sensor inputs Flexible control of Gen-Sets with intelligent system management and Real-Time clock Real time clock function allows the user to program weekly patterns for the generator operation. Time stamped alarm logging is also available for professional user. available and characteristics can be adjusted from the menu to fit any type of sensor. There are altogether 13 i/o ports available, among which many can be configured by the user. Load power is also measured and can be used with dedicated functions in the menu. Decisions can be made depending on active and/or reactive power of the load. Total accumulated active/reactive power is also measured and recorded. The real-time clock allows weekly and/or monthly generator control programs to be made, which can manage periodic test run and /or disabling the generator at certain hours or on specific days. Magnetic pick-up input is available for reliable and accurate measurement and control of engine speed. Independent control of MCB and GCB from front panel Phase sequence and Reverse Power protection for Gen-Set Full digital calibration of all analog measuring inputs Characteristic adaptation table for temperature and pressure sensors Daily or weekly control patterns for the generator, Automatic test run mode SMS message option for alarms PC INTERFACE FOR MONITORING AND SYSTEM PROGRAMMING, SCADA CONTROL REAL TIME CLOCK AND TIME STAMPED ALARM LOGGING PHASE SEQUENCE DETECTION AND REVERSE POWER PROTECTION Additional features: MEASUREMENT OF KW, KVA, KVAr, KWh AND POWER PACTOR MAGNETIC PICK-UP INPUT FOR RPM MEASUREMENT TRUE RMS VOLTAGE AND CURRENT MEASUREMENT Frequency measurement: Charge alternator excitation current: Measurement accuracy: Phase voltages: ±2% of scale, Frequency: ±0.1Hz Frequency measurement: Magnetic pick-up / Alternator phase frequency Protection class: IP52 (front panel protection) FULL ENGINE CONTROL AT+T COMPATIBLE GSM MODEM INTERFACE ENGINE WORKING HOUR METER AND SERVICE TIMER REMOTE START AND STOP MAINS TRANSFORMER WIDE OPERATING TEMP. RANGE (-25°C to +70°C) REAL TIME CLOCK AND TIME STAMPED ALARM LOGGING ALARM LOGGING FOR THE LAST 15 INCIDENTS Relative humidity: Operating temperature: MODBUS/RTU COMMUNICATION INTERFACE PORT SCADA INTERFACE FOR MONITORING AND REMOTE SYSTEM PROGRAMMING Technical specifications: OPERATION INTERFACE MAGNETIC PICK-UP RP

Open the catalog to page 1
AMF3.4L - 2

APPLICATION CONNECTION DIAGRAM Typical connection diagram is shown and this is one of possible applications among many. The system is shown in 3 phase connection but can also be applied for single phase systems. AMF3.4L controller plastic housing is designed according to DIN norms. Mechanical dimensions Mechanical dimensions are shown in the drawing. Plastic housing is made of ABS (with added fiber) which provides high temperature resistance and good mechanical stability. The electrical order to adopt the controller to more specific applications. Magnetic pick-up can be used for rpm...

Open the catalog to page 2

All ENKO Elektronik Kontrol Sistemleri San. ve Tic. Ltd. Sti. catalogs and technical brochures

  1. CCS 4.2

    2 Pages

  2. ESR 3.1

    2 Pages

  3. ESR1.1

    2 Pages

  4. ATS2.0

    2 Pages

  5. MSU4.2

    2 Pages

  6. MSU3.4L

    2 Pages

  7. MSU 2.0

    2 Pages

  8. AMF5.2

    2 Pages

  9. AMF5.1

    2 Pages

  10. AMF4.2

    2 Pages

  11. AMF3.4

    2 Pages

  12. AMF3.2

    2 Pages

  13. AMF3.1

    2 Pages