ENGMATEC Smart Contact Cell
2Pages

{{requestButtons}}

Catalog excerpts

ENGMATEC Smart Contact Cell - 1

ENGMATEC Smart Contact Cell Contacting cell for operation in Lean-Line systems Function Stand-alone test equipment for ICT and FCT tests The equipment to be tested is manually placed on a product-specific carrier. The safety flap closes after actuation of the "Nagara switch". The ENGMATEC tandem shuttle transports the test piece just loaded to the test position after termination of the test process still running in the test position. At the same time, the carrier in the test position returns to the loading position. After automatic opening of the flap, the test piece is ready to be unloaded and the carrier is ready to be loaded again. In test position, the carrier is lifted from below. The carrier centers to the upper test adapter and the test piece is contacted. The lower contacting unit moves and contacts the test piece from below. Tandem shuttle system for utilization of the secondary process time Handling time approx. 3 seconds Interface for test adapter at the top and bottom Fast exchange of test adapters Possible integration of test equipment in the system (11 HP) Integration of scanners in loading area possible ENGMATEC GmbH

Open the catalog to page 1
ENGMATEC Smart Contact Cell - 2

ENGMATEC Smart Contact Cell General equipment description Example Dimensions (L/W/H) Loading height Maximum test piece dimensions (LxW) Approx. 300 x 180 mm others on request Adapter lock Manually via cam lever with query Control unit Touch panel with graphic user interface, language switch-over, user management Space for test technology Handling time Application for optical inspection with Monster Dome TANDEM - SHUTTLE - SYSTEM ENGMATEC GmbH

Open the catalog to page 2

All ENGMATEC GmbH catalogs and technical brochures

  1. BOARDHANDLING

    27 Pages