Catalog excerpts
Commercial Brochure Air to water heat pumps with natural refrigerant CO2 AIRHEAT 2.0 Release June 2022 AIR TO WATER HEAT PUMPS Nominal heating capacity from 10 to 100 kW for domestic hot water production applications or process heating with high delta temperature, up to 90 °C Enex presents AIRHEAT 2.0, the new, renewed and extended range of air to water heat pumps for DHW (Domestic Hot Water) that uses CO2 (Carbon Dioxide - R744) natural refrigerant fluid. A synthesis of innovation, flexibility and energy saving, the AIRHEAT 2.0 series air to water heat pumps offer an unbeatable solution for the ability to produce large quantities of hot water at high temperatures, overcoming the typical limits of traditional heat pumps with synthetic refrigerants. Enex was the first ever company to develop CO2-only solutions since 2004. CO2 is a natural fluid with zero OPD, GWP = 1. Neutral refrigerant of excellence, CO2 is neither toxic nor flammable: it is in fact the one of the natural gases with fewer contraindications and for this reason it is a candidate as the refrigerant of the future, not subject to the F-gas regulation on fluorinated gases. Copyright © ENEX S.R.L - Società a Socio Unico Via Veneto 12, 31038 Padernello di Paese (Treviso), Italy | P.IVA IT02328320300 Tel +39 0422 440429 | Fax +39 0422 961021 | info@enex.it | www.enex.it
Open the catalog to page 1Commercial Brochure Air to water heat pumps with natural refrigerant CO2 Publication: Commercial Brochure, AIRHEAT 2.0 Series | Release June 2022 | ENG Copyright © ENEX S.R.L. Società a Socio Unico Via Veneto 12, 31038 Padernello di Paese (Treviso), Italy | VAT IT02328320300 Tel +39 0422 440429 | Fax +39 0422 961021 | info@enex.it | www.enex.it All rights reserved in all Countries. The technical data and information expressed in this publication are owned by ENEX S.R.L. and have general information. With a view to continuous improvement, ENEX S.R.L. has the right to make at any time,...
Open the catalog to page 2Commercial Brochure Air to water heat pumps with natural refrigerant CO2 THE KEY ROLE OF THE HEAT PUMP TECHNOLOGY IN EUROPE The key role of heat pumps, for the heating, cooling and production of domestic hot water in buildings, for the achievement of the new European community decarbonisation objectives of the building sector for the next decade, is perfectly reflected in the "European Green Deal" which expects the EU to become the first climate-neutral continent by 2050. Air Ambient Heat Source Distribution System HEAT PUMP Examplification image of the heat pump technology In the...
Open the catalog to page 3Commercial Brochure Air to water heat pumps with natural refrigerant CO2 TYPICAL SYSTEM CONFIGURATIONS TO ADAPT TO THE DIFFERENT NEEDS AIRHEAT 2.0 heat pumps represent a flexible and intelligent choice to manage according to the different configurations and system needs: technical water and domestic hot water for both instantaneous production and storage. Here are some examples of typical uses that take advantage of the stratification principle. INSTANTANEOUS TECHNICAL WATER PRODUCTION AND STORAGE OF DOMESTIC HOT WATER STORAGE OF TECHNICAL WATER AND INSTANTANEOUS PRODUCTION OF DOMESTIC HOT...
Open the catalog to page 4Commercial Brochure Air to water heat pumps with natural refrigerant CO2 GENERAL TECHNICAL DATA AH10 Design conditions Design conditions Design conditions SPECIFICATIONS DESCRIPTION OF STANDARD UNITS AIRHEAT 2.0 unit for the production of domestic hot water up to 90°C with process water with a high temperature difference, equipped with heat pump technology with high energy efficiency CO2 natural refrigerant in an Air-Water monobloc configuration for nominal heating capacity from 10 to 100 kW. Main components: - Compressor: semi-hermetic, specifically designed for transcritical CO2...
Open the catalog to page 5Commercial Brochure Air to water heat pumps with natural refrigerant CO2 DETAILED TECHNICAL DATA ELECTRIC DATA AH10 LRA with soft starter (A) Electric alimentation HYDRAULIC DATA Pump type Av. Pressure Drop (m) SOUND POWER LEVELS FRIGORIFIC CIRCUIT MAIN COMPONENT AH10 N. circuits /compressor Type compressor Semi hermetic Semi hermetic Semi hermetic Semi hermetic Semi hermetic Semi hermetic Semi hermetic Tyoe Refrigerant Refrigerant charge (kg) Number of fans COOLING HEAT RECOVERY AIRHEAT 2.0 heat pumps are able to recover cooling energy for the production of cold water, which can be...
Open the catalog to page 6Commercial Brochure Air to water heat pumps with natural refrigerant CO2 STANDARD CONFIGURATIONS OPTIONS AND ACCESSORIES SOFT STARTER WATER PUMP DHW WATER PUMP (Alternative) DUCTED OPTION COLD RECOVERY COIL CORROSION PROTECTION MODBUS TCP/IP REMOTE MONITORING Depending on the size and model, AIRHEAT 2.0 units can be equipped with a series of devices that expand the range of use and improve the completeness of the unit: - ON / OFF Compressor control; - Soft Starter; - Inverter; - Water pump (always included); - Domestic hot water pump (option); - Ducted option; - "Low Noise" option; -...
Open the catalog to page 7Commercial Brochure Air to water heat pumps with natural refrigerant CO2 WORKING CONDITIONS AND LIMITS OF USE AH10 DIMENSIONS, WEIGHTS AND SPACE OF RESPECT Dimensions L x P x H (mm)
Open the catalog to page 8Commercial Brochure Air to water heat pumps with natural refrigerant CO2 APPLICATION EXAMPLE 1: DWH STORAGE When instantaneous technical water production and storage of domestic hot water is required, the advantages represented by the stratification principle combined with the system design can offer relevant benefits in terms of energy efficiency and service level to the users. In the scheme below, purely by way of non-exhaustive example, it is represented a simplified schematic solution where the position of the plate heat exchanger and the piping design allow to have the highest...
Open the catalog to page 9Commercial Brochure Air to water heat pumps with natural refrigerant CO2 APPLICATION EXAMPLE 2: TECHNICAL WATER STORAGE When storage of technical water and instantaneous production of domestic hot water is required, the advantages represented by the stratification principle combined with the system design can offer relevant benefits in terms of energy efficiency and service level to the users. In the scheme below, purely by way of non-exhaustive example, it is represented a simplified schematic solution where the position of the plate heat exchanger and the piping design allow to have the...