SFM-Series, Split-Flow Manifolds ▼ Shown from left to right: SFM41, SFM42 Split-Flow Manifolds Improved safety on basic simultaneous lifting applications Pressure Gauges G2535L Glycerin filled pressure gauges are installed in each outlet pressure line to monitor the pressure of each cylinder. Optimum Performance • Split-Flow Manifolds improve safety, precision and control in lifting and lowering operations • Pressure gauge, flow control valve in each outlet port; CR400 couplers installed in each inlet and outlet port • Regulates both advance and retract speeds: lifting and lowering • 1 inlet, 4 outlets. Maximum of 4 cylinders per manifold: SFM41 for single-acting cylinders, SFM42 for double-acting cylinders • Minimum pump oil flow: 50 in3/min to deliver 9.1 in3/min per cylinder • Maximum difference among outlets: 10% of the stroke • More cylinders can be controlled simultaneously by connecting several SFM-models parallel Minimum pump oil flow must be 50 in3/min to deliver 9,1 in3/min per cylinder. Enerpac recommends to use Z-Class electric, air driven or gasoline pumps from the ZU4, ZE4, ZE5, ZA4 and ZG-Series. SFP-Series, Split-Flow Pumps When a higher accuracy is required across cylinder strokes in a multi-point lifting or lowering application Enerpac recommends using the SFP-Series Split-Flow Pumps. Contact Enerpac! Contact the Enerpac office nearest to you for advice and technical assistance in the layout of your ideal Lifting System or visit us at: www.enerpac.com. Or ask Enerpac for assistance: enerpac.com/contact-us ◀ To repair the foundation, silos needed to be lifted, levelled and structurally supported. Powered by a ZE5-Series electric pump the split-flow manifold used to operate multiple hydraulic cylinders.
Open the catalog to page 1a Split-Flow Manifolds The SFM-Series offer an economical solution for basic multi-point simultaneous lifting applications and enables a single operator to control a maximum of 4 lifting points from one manifold. The Split-Flow Manifolds are equipped with pressure compensated flow control valves, to preset and limit advance and retract speed of each cylinder, allowing to move up to 4 cylinders simultaneously. The SFM-Series provide more lifting and lowering control compared to AM-Series Control Manifolds. See flow control valve adjustments table below. Minimum pump oil flow must be 50 in3/min...
Open the catalog to page 21 Page
1 Page
136 Pages
428 Pages
2 Pages
4 Pages
2 Pages
10 Pages
1 Page
3 Pages
2 Pages
14 Pages
1 Page
1 Page
2 Pages
2 Pages
6 Pages
40 Pages
8 Pages
1 Page
50 Pages
1 Page
2 Pages
13 Pages
2 Pages
4 Pages
1 Page
4 Pages
20 Pages
288 Pages
294 Pages
1 Page
2 Pages
280 Pages
88 Pages
88 Pages
268 Pages
16 Pages
2 Pages
258 Pages
88 Pages
4 Pages
2 Pages
4 Pages
2 Pages
92 Pages
28 Pages
232 Pages
260 Pages