Activator wand and booster Shown: RA-1061, B-81 Collet-Lok® products Contamination resistant closed hydraulic system • No-leak palletized system, eliminates oil loss at connection point • Closed design prevents machining chips and coolant from entering the hydraulic circuit Mechanical energy transfer system uses external cylinder to operate receiver booster. Pressure Gauge G-series Bleeder Valve Hydraulic Accumulator Activator Wand Hydraulic hose Bleeder Valve Power Sources Hydraulic system schematics The Activator Wand RA-1061 is placed into the receiver booster B-81 or B-171. The mechanical transfer of force from the activator wand plunger to the booster piston provides oil flow to the system. Linear Cylinders Work Supports Swing clamps • Booster can be mounted in either horizontal or vertical position for flexible fixture design. Receiver booster Pallet Components Shut-off valve Swing Cylinders ❚ A manually placed Wand and Booster system is used to clamp the castings in this machining fixture. Product selection Pressure Oil flow Oil Stroke Model Effective Operating ratio ratio volume number area pressure per stroke 3 cm mm cm2 bar kg ▼ Receiver booster

Open the catalog to page 1
Enerpac Workholding Catalogue E215e - 2

Existing fixtures with manual-connect single-acting circuits can be easily upgraded into the wand and booster. The activator wand has a 2 to 1 ratio of input pressure versus output force. The booster output flow is 1,75 times the wand input flow. Pallet Components System Components Yellow Pages

Open the catalog to page 2
Enerpac Workholding Catalogue E215e - 3

Application & selection Collet-Lok® products For high production applications • High speed operation • Extended service life • Constant hydraulic output Swing clamps • Large oil delivery per stroke allows quick filling of cylinders for clamping or punching AHB series boosters • Fiberglass wound air chamber eliminates possibility of rust due to moisture in air system • Designed for fully automated production applications Work Supports • Double-acting, one-shot, high speed operation of air piston B series boosters • One-shot spring return Large effective area of air piston allows compressed...

Open the catalog to page 3
Enerpac Workholding Catalogue E215e - 4

Dimensions & Options AHB, AHB-series – Oil pressure vs Air pressure B-series – Oil pressure vs Air pressure Air: 27 - 64 dm3/cycle E Multiplicadores F Multiplicateurs D Druckübersetzer Gauge port Important Oil fill port Gauge port Boosters can provide high oil flow rates based on the volume of in-coming air. Stroke sensor For vertical mounting of booster, an elbow fitting is recommended for the oil reservoir. Selection chart One cycle = advance + retract stroke. Note: Seal material: Buna-N, Polyurethane. Yellow Pages Oil pressure Oil volume Air to oil Model Air Air Hydraulic Hydraulic Air...

Open the catalog to page 4
Enerpac Workholding Catalogue E215e - 5

Pallet Components Valves Power Sources Linear Cylinders Work Supports Swing clamps Collet-Lok® products When hydraulic pressure from an existing power source is limited, Enerpac oil-to-oil intensifies serve to increase output pressure to satisfy the required application. 178 ENERPAC. @ High flow units intensify low inlet oil pressure to high outlet pressure • Internal bypass valving enables high output flow rates • Wide range of intensification ratios allows for adapting to various operating pressure requirements • Compact and self-contained design allows for ease of installation • Includes...

Open the catalog to page 5
Enerpac Workholding Catalogue E215e - 6

System set-up information: Ratio: 1 : 3,2 -1 : 6,6 With dump valve (PID models) The intensifier with the dump valve is used to achieve high pressure on the advance side of a double-acting cylinder. Flow: 1,2 - 2,5 l/min Pressure: 65 - 700 bar JEJ Multiplicadores F_y Multiplicateur Dy OI-OI Druckubersetzer With external dump valve In a system where the pump’s oil flow is higher than the maximum inlet oil flow of the intensifier, an external check valve and flow control valve reduces the pump’s oil flow. Low This application can be set up pressure when machines are equipped with low pressure...

Open the catalog to page 6
Enerpac Workholding Catalogue E215e - 7

Application & selection Collet-Lok® products …maintain circuit pressure • Ideal for high frequency and rapid discharge applications • ACL series are pre-charged to 100 bar • Corrosion resistant bodies on ACL series Swing clamps • Spring actuated accumulator for ACM-1 • High energy storage capacity in a compact package • WA accumulators are piston type • ACL accumulators are diaphragm type Work Supports • ACM accumultors use internal spring. E nerpac accumulators supply auxiliary pressure to dampen shock loads or to compensate pressure Power Sources Linear Cylinders drop in applications...

Open the catalog to page 7
Enerpac Workholding Catalogue E215e - 8

^ Recommended pre-charge Operating Model Nitrogen Usable oil pressure number pressure capacity 1) 11 At maximum operating pressure. Pressure: 0 - 350 bar D Oil volume: 1,6 - 337,6 cm3 [jGas volume: 20 - 450 cm3 v Ej Acumuladores Fj Accumulateurs Dj Druckspeicher 9 AW-50 Mounting block For WA-series accumulators. number ▼ Pre-charged accumulators ACM-1 133 19 Recommended charging tool kg Pallet Components System Components Yellow Pages

Open the catalog to page 8

All ENERPAC catalogs and technical brochures

  1. Manifolds

    3 Pages

  2. Load Skates

    2 Pages

  3. LW-series

    1 Pages

  4. MP series

    1 Pages

  5. MS-Series

    4 Pages

  6. TM LH Series

    1 Pages

  7. E328a

    288 Pages

  8. A, C-Series

    1 Pages

  9. STB-Series

    2 Pages

  10. E328e

    280 Pages

Archived catalogs

  1. E213e

    140 Pages

  2. E214

    195 Pages

  3. E411e

    76 Pages