1. Catalogs
  2. Energy Support
  3. VLF40 und VLF60

VLF40 und VLF60

VLF40 und VLF60

VLF40 und VLF60

Product catalog summary
Introduction
High Voltage, Inc. offers a range of Very Low Frequency (VLF) AC Hipots designed for AC testing of cables and electrical apparatus. These devices are portable, affordable, and suitable for field-testing various loads, including cables and rotating machinery. The VLF Hipots are available in models ranging from 28 kVac to 200 kVac, capable of testing up to 50mF of load and cables over 50 miles in length.

Product Features
HVI's VLF Hipots are known for their rugged and reliable design, featuring electro-mechanical controls and oil-filled HV power supplies. These designs are field-serviceable and have a proven track record with over 900 units in service since 1998. The VLF Hipots produce a sine wave output that meets global standards, making them suitable for Tan Delta and Partial Discharge cable diagnostic testing.

Model Specifications
  • VLF-4022CM(F): This model has a 44 kVac peak output, suitable for testing cables rated up to 25 kV. It can test over 10 miles of cable and includes a charging current and load capacitance meter. It features a two-piece construction for easy transport and storage.
  • VLF-6022CM(F): With a 60-62 kVac peak output, this model is suitable for cables rated up to 35 kV. It can test over 15 miles of cable and includes enhanced features such as a test dwell timer and polarity indicating lights. It also has a two-piece construction for portability.

Technical Specifications
Both models operate on 120 volts or 230 volts, with continuous duty and load ratings up to 5.5 μF. They include voltmeters, charging current meters, and load capacitance meters. The VLF-4022CM(F) and VLF-6022CM(F) models differ in size, weight, and specific output capabilities.

Additional Options
HVI offers various options for their VLF Hipots, including Tan Delta Diagnostic Bridge, Automatic Data Logger, Hand Truck Mounting, and 100’ cable reels. Other models are available with higher voltage capabilities, ranging from 28kV to 200kV.

Conclusion
High Voltage, Inc. provides a comprehensive range of VLF Hipots with advanced features and reliable performance for utility and industrial applications. Their products are protected under U.S. Patent # 6,169,406 and are used in nearly 70 countries worldwide.
See more

Catalog excerpts

VLF40 und VLF60-1

HIGH VOLTAGE HVI - The World’s VLF Source Nearly 70 countries served since 1998 • Greatest Model Selection • Highest Voltages Available • Highest Power Ratings Delivered • Only VLF Thumper Produced • Rugged oil filled non-electronic design offers extreme reliability and ease of field service if ever necessary Very Low Frequency AC Hipots VLF-4022CM(F) 0 - 44 kVac peak up to 5.5 mF VLF-6022CM(F) 0 - 60-62 kVac peak up to 5.5 mF AC testing of cables and electrical apparatus is now easier than ever. Since the introduction of the High Voltage, Inc, line of portable and affordable VLF hipots, there is a practical method of AC fieldtesting various loads, particularly cables and rotating machinery, High Voltage, Inc, offers a full line of VLF AC Hipots from 28 kVac to 200 kVac with models that can test up to 50pF of load, cables over 50 miles in length and the largest of generators/motors, Use VLF for AC stress tests and/or as a voltage source for Tan Delta and Partial Discharge cable diagnostic testing, SINCE 1998, HVI has produced the most rugged and reliable VLF OUTPUT ADJUST HIGH VOLTAGE HIGH VOLTAGE -On products available. Our electro-mechanical control and our oil filled HV power supply designs are extremely dependable, and if necessary, more easily field serviced than the electronic designs of others. The HVI design has a proven 12 year track record with over 900 units in service. The HVI VLF design offers the best of everything, with manual, easy to use controls but also sophisticated data collection. Electric utilities and industrials have long recognized the benefit of our technology. HVI knows how to build long lasting field test equipment. The HVI VLF design produces a sine wave output that meets all requirements of world standards, permitting it to be used as a voltage source for VLF-6022CM - Front Panel Simple to use, manual controls. No programming necessary. Tan Delta and Partial Discharge cable diagnostic testing. Non sine wave producing VLF designs are limited in this ability and may reduce the users’ options in the future to use the VLF for diagnostic testing. Stick to the HVI sine wave producing VLF. HIGH VOLTAGE, INC. 31 County Route 7A • Copake, NY 12516 • (518) 329-3275 • Fax: (518) 329-3271 • www.hvinc.com

 Open the catalog to page 1
VLF40 und VLF60-2

This model, with its 44 kVac peak output, is suitable for testing cables rated up to 25 kV. Its high load capacity enables it to test up to over 10 miles (16 km) of cable, depending on type. This model includes a charging current and load capacitance meter, and a center zero peak kilovolt output meter. The two piece construction permits the VLF-4022CM to be more easily transported and stored than others. Input: Output: 120 volts, 60 Hz, 10 A peak, 5 A average or 230 volts, 50/60 Hz, 6 A peak, 2.5 A average (F suffix) 0 – 44 kVac peak, 0.1/0.05/0.02 Hz sinusoidal Load Rating: 1.1μF @ 0.10 Hz:...

 Open the catalog to page 2

All Energy Support catalogs and technical brochures

  1. MOBILE GC

    4  Pages

  2. SIGMA 2000

    2  Pages

  3. TOP TOGA GC

    3  Pages

  4. TDM 4000

    4  Pages

  5. ICMcompact

    3  Pages

  6. VLF-34E

    1  Page

  7. VLF28

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.