» One-touch operation » Fully automatic procedure » ulti-periodic vacuum degassing M » ull TOGA analysis (11 gases) and Total Gas Content F » utomatic transfer of gas sample A » asy calibration of the whole system with traceable calibration gas E » ccurate measurement of total gas content A » ost sensitive detection for Acceptance- Service- and Routine tests (0,1ppm) M » daptable for Factory Transformer Heat-Run tests A » deal solution for laboratories and workshops I » uto-sampler available for 16 – 32 samples for unattended operation A » xpert System for quick and easy conclusions Evaluation according to: E IEC 60599, Roger ratios, Duval etc. The TOP TOGA GC has been designed for a fast and reliable measurement routine. The analysis –done in 2 steps – follows the exact ASTM and IEC standard guidelines. For many decades Dissolved Gas Analysis has proven to be a favourable method for insulation diagnosis. The TOP TOGA GC has been developed to be userfriendly and deliver reliable and more accurate results. Dissolved Gas Analysis with automatic full vacuum degassing according to ASTM D3
Open the catalog to page 1Gases and Detection ranges: H2 The Auto-sampler Technology has been designed to increase the efficiency of the TOP TOGA system to make it more user –friendly, cost-effective and for easy interpretation of results. It provides optimum value, time-efficiencies and excellent performance. There is no longer a need to change sample containers once the oil sample is taken from the transformer. All results are displayed in ppm, sensitivity is as low as 0 1 0,1ppm f h d for hydrocarbons. Therefore, new b Th f Simply plug your syringe into the sample tray – absolutely contamination free. The TOP...
Open the catalog to page 2Vacuum degassing: Vacuum sensor: Sample volume: Gas Chromatograph: Calibration: Power Supply: Gas requirements: Width/Height/Depth: Weight: Oil- and Mercury-free 0,1 - 200 mbar 30 - 100 ml Thermal Conductivity Detector (TCD) Flame Ionisation Detector (FID) Methanizer 2 Micro packed columns Furnace cassette with column and temperature programmed column heating system, separate heating and cooling of each column. Sample tray interchangeable for 100ml, 50 ml or 30 ml glass syringes Available for 16 or 32 samples For all types of transformer oils (new and used) Procedure fully-automatic,...
Open the catalog to page 3All Energy Support catalogs and technical brochures
-
Total Dissolved Gas Content
4 Pages
-
Pocket Titrator KF
2 Pages
-
MOBILE GC
4 Pages
-
SIGMA 2000
2 Pages
-
TDM 4000
4 Pages
-
ICMcompact
3 Pages
-
VLF-34E
1 Pages
-
VLF28
2 Pages
-
VLF40 und VLF60