Catalog excerpts
» State of the Art Technology - Portable Gas Chromatograph » Available in different versions » Fully automatic measurement procedure » Fully compliant with ASTM D3612 and IEC 60567 » Automatic sample injection » High Sensitivity through Vacuum Degassing » High Selectivity through Gas Chromatography » Highly sensitive detection of up to 11 gases » Suitable for Acceptance- Service- and Routine tests » Ideal for on-site measurements and also for laboratories » Direct analysis of Buchholz gases » Rugged case-waterproof for extreme environmental conditions » Expert System for quick and easy conclusions Evaluation according to: IEC 60599, Roger ratios, Duval etc. The MOBILE GC's unique characteristic is its ability to function both under on-site conditions and also in the laboratory. The Dissolved Gas Analysis allows early recognition of transformer defects and possible failures. By observing the manufacturers'established service intervals and through use of the MOBILE GC unnecessary and substantial breakdown costs are minimized dramatically.
Open the catalog to page 1After fixing a syringe with 10ml oil the degassing procedure is started automatically. The user interface provides step-by-step guidance. After degassing the oil, the gas sample is automatically injected into the sample loop and the gas chromatographic analysis is started. During the degassing procedure the total gas content is measured. ENERGY SUPPORT
Open the catalog to page 2The MOBILE GC is equipped with an Expert System Software. Automatic fault diagnosis of the sampled oil based on the various concentrations, reference values, and ratios of certain gases is performed. You no longer need to be an expert to analyse the gas content in oil. Measurement no: 1 ; Expert system ;| Data base: | Method by IEC5991997 1.Dissolved gases analysis: Component | Concentration [ppm]~ Possible arcing Possible severe local overheating Possible local overheating, possible low energy spark 3.Evaluation of gas ratios according to IEC599-1997: | Code Fault codes/typical...
Open the catalog to page 3Measurement technology: Gas in oil measurement range: Accuracy/Resolution: Calibration: Sampling: Power supply: Gas requirements: Operating temperature: Width/Height/Depth: Weight: Housing: Full gas chromatographic analysis using TCD and FID detector and methanizer 0,1 -10O.OOOppm Applicable for new and used oils ±10%/0,1 ppm With traceable calibration gas or gas in oil standard 10 ml oil sample Gas tight glass syringe to ensure no gas loss or contamination with ambient air 100-240VAC, 50/60HZ Outer power supply of 12 V is usable and can be operated for 6 hours 99,999% purity Argon 99,999%...
Open the catalog to page 4All Energy Support catalogs and technical brochures
-
Total Dissolved Gas Content
4 Pages
-
Pocket Titrator KF
2 Pages
-
SIGMA 2000
2 Pages
-
TOP TOGA GC
3 Pages
-
TDM 4000
4 Pages
-
ICMcompact
3 Pages
-
VLF-34E
1 Pages
-
VLF28
2 Pages
-
VLF40 und VLF60
2 Pages