Catalog excerpts
EMULSION SPLITTING EQUIPMENT Installation and Operation Manual for Oil-water separator
Open the catalog to page 111. ELECTRICAL INSTALLATION ‐‐‐ 16 12. CONSUMABLES AND PARTS --- 17 13. OUR PRODUCT RAN
Open the catalog to page 2◆ Please read this Manual before installation and use of Envisol®. ◆ All functions of ENVISOL® are guaranteed only when the instructions given in this Manual have been observed. ◆ Keep this Manual near the Emulsion Splitting Equipment for quick reference during error events and maintenance. 1. Authentic filter bags and emulsion splitting chemical manufactured by EnE System must be used with this product. 2. The Emulsion Splitting Chemical must be stored in a dry place to preserve the effects of the chemical. The chemical exceeding the shelf life must be disposed of as it is no longer...
Open the catalog to page 3① Press Relief Chamber ⑥ Stirred Tank ⑨ Chemical Sludge Filter ⑫ Treated Water Outlet ⑬ Chemical Motor ① Press Relief Chamber: High pressure condensate is discharged from each outlet. If high pressure condensate is entered nto the Pre-separation tank, the oil separation by specific gravity will be affected unless condensate is depressurized. ② Pre-separation Tank: Condensate containing a little bit of oil enters into the Pre-separation tank, and the oil is separated by gravity. Condensate after de-oiling is stored in this tank. ③ Level Sensor(S1): Activates the Emulsion Splitting Equipment...
Open the catalog to page 4① Press Relief Chamber ⑥ Stirred Tank ⑫ Treated Water Outlet ⑨ Chemical Sludge Filter ① Press Relief Chamber: High pressure condensate is discharged from each outlet. If the high pressure condensate is entered into the Pre-separation tank, the oil separation by specific gravity will be affected unless the condensate is depressurized. ② Pre-separation Tank: Condensate containing a little bit of oil enters into the Pre-separation tank, and the oil is separated by gravity. Condensate after the oil separation is stored in this tank. ③ Level Sensor(S1): It activates the Emulsion Splitting...
Open the catalog to page 5① Press Relief Chamber ② Pre-separation Tank ③ Level Sensor(S1) ④ Metering Pump ⑤ Oil Drain Valve ⑥ Stirred Tank ⑦ Chemical Tank ⑧ Agitator Motor ⑨ Chemical Sludge Filter ⑩ Chemical Sensor(S2) ⑪ Agitator Level Sensor(S3) ⑫ Treated Water Outlet ① Press Relief Chamber: High pressure condensate is discharged from each outlet. If the high pressure condensate is entered into the Pre-separation tank, the oil separation by specific gravity will be affected unless the condensate is depressurized. ② Pre-separation Tank: Condensate containing a little bit of oil enters into the Pre-separation tank,...
Open the catalog to page 63. PROCESS (Condensate Treatment) (Please refer to Figures in Page 4, 5 and 6.) ◆Emulsion Splitting Equipment "ENVISOL®" is used to purify condensate with the use of emulsion splitting chemicals. It is strongly recommended that suitability testing is performed with us before selecting this device. The suitability of the product to your various applications will be reviewed. ◆ You must comply with the applicable laws and regulations on wastewater treatment. Emulsified condensate enters into the Press Relief Chamber (1) and depressurized in the chamber. Once depressurized, emulsified...
Open the catalog to page 7▶ Install the pipes as shown in the above picture ensuring that condensate enters through the ENVISOL® chamber. ▶ Install ENVISOL® on a level floor. ▶ Connect hoses to and from ENVISOL® ensuring that there is no leak. ▶ During installation of the condensate collection line, ensure that nothing interferes with the air pocket inside the pipe and the flow of condensate. ① Connect the oil container to the Pre Tank using the hose, and fasten the hose with the hose band. ④ Connect the Inlet of Pre Tank and the Water Outlet respectively to complete installation. ② Install the Filter Bag as...
Open the catalog to page 85. MAINTENANCE Checking of Condensate: ▶ Check the condensate discharged from ENVISOL® twice a week. Adjust the chemical setting if it is visually the same as or darker than the specimen. Cleaning of Agitator Container and Condensate Pipeline Sensor (Level Sensor) Clean the chemical and around the Level Sensor. (As it may cause malfunction of the Sensor.) Brush off the chemical sludge from the wall of Stirred Tank. --> Clean once or twice a week. > week EnE System shall not be held responsible for malfunction of the product caused by the user's poor maintenance. Condensate Flowing Path...
Open the catalog to page 96. FILTER BAG REPLACEMENT ▶ Filter bags are easily replaced and kept clean with the ENVISOL ® Series. ① Remove the Filter Bag and dispose of it in a separate container. ② Install new Filter Bags as shown in the picture. ③ The number of Filter Bags varies from Model to Model: ‐ ESP‐25 Filter Bag ‐‐> 1 ‐ ESP‐50/100 Filter Bag ‐‐> 2 ‐ ESP‐200/300 Filter Bag ‐‐> 3 (Refer to the above pictures) Note: Ensure that the filter bag touches the floor, and is fastened by the band. Note: Once the filter bag is full of chemical sludge, replace with new ones. Note: If the filter bag full of...
Open the catalog to page 10An automatic temperature controller (heating system) shall be installed with ENVISOL® to prevent the risk of freezing when it is installed and used at a place exposed to freezing. A heating system suitable for the model of your choice shall be used. The Heating System can be purchased as an option when you purchase the product, or it can be Function When the water temperature drops below the set value, the heating system is automatically activated. The operational status of the controller is indicated by a lamp. When the water temperature reaches the set value, the heating system is...
Open the catalog to page 11Sludge Filter Sensor Chemical Setting Level Sensor Chemical Sensor Metering Pump Chemical Motor Agitator Motor Power Earth
Open the catalog to page 16OUR PRODUCT RANGE ► Auto Drain Trap (Level-sensor type) DRAIN MASTER •DRAIN MASTER S Auto Drain Trap (solenoid valve type) •DRAIN MASTER HP Auto Drain Trap for High Pressure (Max 60 bar) •DRAIN MASTER B Auto Drain Trap (Ball valve type) •DRAIN MASTER V Auto Drain Trap for Vacuum •DRAIN MASTER T Auto Drain Trap (Timer type) YUSOO-BREAKER • Filter Type oil-water Separator
Open the catalog to page 18All ENE SYSTEM catalogs and technical brochures
-
Yusoo 8-200
21 Pages
-
ESP-25 50 100 200 300
25 Pages
-
Drain Master
51 Pages
-
VA 500/520
12 Pages
-
VA 550/570
12 Pages
-
YUSOO BREAKER TECHNICAL DATA
15 Pages
-
DM-50 PLUS TECHNICAL DATA
3 Pages
-
DM-5S PLUS TECHNICAL DATA
3 Pages
-
DM-5N PLUS TECHNICAL DATA
3 Pages
-
YUSOO BREAKER
12 Pages
-
2017 Catalogue
28 Pages
Archived catalogs
-
DRAINMASTER B
4 Pages
-
DRAINMASTER S
6 Pages