DRAINMASTER S - 2

Auto Drain Trap FLOAT TYPE • Nozzle caliber is small structurally that is often blocked so that there needs periodic dissolution and cleaning (0.70). 9 If alien substance rises at Float Nozzle is not closed that air loss is occurred continuously. # In case of oil supply compressor, density of oil drops Float's buoyancy. TIME C0NT0L Solenoid Valve # Solenoid controlled valve receives compression pressure directly that there are a lot of disabilities. • Time setting by condensate volume is difficult that air loss is big. • When discharge noise is heavy. MANUAL VALVE • Compressed air making by...

Open the catalog to page 2
DRAINMASTER S - 3

Reason and solution of condensate occurrence in compressor system • Compressor inhales air from atmosphere and saturated vapor that is flowed when compress becomes water in compression process. # In the case of condensate, was polluted extremely by dust in air, pollutant, oil etc., in the case of oil free compressor, it is acidified that causticity is strong. Condensatel What is problem? # Corrodes and contaminates compressed air piping, air tank, air filter etc., and furthermore, it gives serious effect to high equipment and product in production • In the case of winter, condensate is...

Open the catalog to page 3
DRAINMASTER S - 4

Advantage that is DRAIN MASTER Electrostatic capacity sensor Any condensate from compression process can be sensed correctly and There are little loss of compressed air. Uses of two sensors (High level, low level) protects energy loss by air loss discharging condensate selectively. Normal Mode Alarm Mode Automatic discharge function In case of condensate is not discharged while 2 minutes by scale etc., it makes recognition to user through alarm signal and it is converted to automatic restoration function and it activates electric motion ball valve by 5 seconds every 3 minutes. It is...

Open the catalog to page 4
DRAINMASTER S - 5

Technical specification Green : Dry and cool climate (such as in Northern Europe, Canada, Northern states of the USA, Central Asia) Blue : temperate climate(such as in Central and Southern Europe, Central Americal) Red : humid, tropical climate(such as in the coastal regions of South-East Asia, Oceania, Amazon and Congo regions) TECHNICAL DATA ► Must attach automatic thermostat (option : Heater/110.220Vac) in freezing area. ► Else above models are custom-built. ► Above specification can be changed without advance notice for improvement of performance(2013.01j

Open the catalog to page 5
DRAINMASTER S - 6

Head office : EnE SYSTEM CO.,Ltd #290, Goryeom-ri, Cheongbuk-myeon, Pyeongtak-si, Gyeonggi-do, Korea URL : www.enesystem.com E-mail: enesystem@enesystem.com T: 82-31 -234-4001 F: 82-31 -234-4222

Open the catalog to page 6