Model and Specifications
Model: DM-50 Plus
Order Reference: DM 50 PA
Working Pressure: 0.8 to 16 bar
Temperature Range: +1℃ to +80℃
Safety Class: IP 65
Weight (empty): 2.3 kg
Scope of Application: Suitable for both oil-free and oil-contaminated condensate.
Technical Features
Condensate Feed: G1/2" (NPT 1/2") x 3 points
Venting Line: G1/2" (NPT 1/2")
Condensate Discharge: G1/2" (NPT 1/2")
Voltage: 100~240Vac (Free Voltage) / 50~60Hz, 24Vac, 48Vac / 24Vdc, 48Vdc
Cable Cross Section: Ø 6.0 ~ 8.0 mm; 3 x 0.75mm
Power Input: 15 VA
Fuse Protection: 0.5 A (normal lag)
Climatic Zones and Performance
Green Zone (Dry and Cool Climate): Peak compressor performance 115 m3/min, Peak dryer performance 230 m3/min, Peak filter performance 1150 m3/min
Blue Zone (Temperate Climate): Peak compressor performance 100 m3/min, Peak dryer performance 200 m3/min, Peak filter performance 1000 m3/min
Red Zone (Humid, Tropical Climate): Peak compressor performance 70 m3/min, Peak dryer performance 140 m3/min, Peak filter performance 700 m3/min
Optional Features
Thermostatically Controlled Heating: Available as an option
Operating Pressure with Heating Unit: Max 25 bar, suitable for temperatures down to -25℃
Heater Unit Power: 220Vac/50~60Hz/125W or 110Vac/50~60Hz/125W
Materials
Housing: Aluminum, Hard Coated
Diaphragm Cover: POM
Diaphragm Seat: Aluminum, Hard Coated
Valve Coil: PA (Polyamide)
Plunger or Tube Guide: Stainless Steel SUS430F
Diaphragm: HNBR
PCB Board Casing: ABS
O-ring: NBR
Additional Information
Subject to technical changes without prior notice, errors not excluded.
See more

Catalog excerpts

DM-50 PLUS TECHNICAL DATA-1

Condensate Auto Drain Trap Technical Data Condensate Auto Drain Trap Delay Program Model Model : DM-50plus Order Ref. : DM 50 PA

 Open the catalog to page 1
DM-50 PLUS TECHNICAL DATA-2

DRAIN MASTER TECHNICAL DATA Working Pressure (min/max) Temperature (min/max) Safety Class Condensate Feed Venting Line Condensate Discharge Oil-Free Condensate or Oil-Contaminated Condensate Cable cross section Thermostatically controlled heating (Option) Heater Unit Operating Pressure(max) with heating unit and proper insulation; down to -25C

 Open the catalog to page 2
DM-50 PLUS TECHNICAL DATA-3

Condensate Auto Drain Trap DRAIN MASTER DIMENSION DRAIN MASTER (DM-50 Subject to technical changes without prior notice, errors not excluded. EnE-DM50-Plus-E003

 Open the catalog to page 3

Archived catalogs

  1. DRAINMASTER S

    6  Pages

  2. DRAINMASTER B

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.