pH measuring technology, Sensors, assemblies and transmitters for all applications - 1

Sensors, assemblies and transmitters for all applications >

Open the catalog to page 1
pH measuring technology, Sensors, assemblies and transmitters for all applications - 2

With the new Ceragel and Tophit sensors, Endress+Hauser is presenting sensor types whose capabilities can hardly be beaten. The CPS71 sensor is the only sensor on the market with an innovative double chamber and double gel reference system with a classic design, i.e. 120 mm length and 12 mm shaft glass diameter. New gel compositions ensure a high level of protection against contamination and a wide measuring range of 0 to 14 pH. Longer operating times are automatically guaranteed here. Especially for fermenter applications, the CPS71 is available with pressurized reference and also in a...

Open the catalog to page 2
pH measuring technology, Sensors, assemblies and transmitters for all applications - 3

The ambitious implementation of the modular measuring point concept in all assemblies of a pH measuring point allows the customer to instrument from a high-quality low-cost version right up to a complete high-tech application all from the one shop. If developing a manual measuring point right up to a fully automatic pH solution, the user finds the ideal solution for every requirement. Well planned and thought-out modular concepts give the customer the opportunity of introducing the optimum sensor into the process. There is a great range of assemblies to choose from with so many different...

Open the catalog to page 3
pH measuring technology, Sensors, assemblies and transmitters for all applications - 4

The pH sensors can be optimally integrated into the processes with the aid of Endress+Hauser assembly technology. Almost any process connection can be made. The CPA472D assembly series is available for high temperatures and 10 bar pressure. Many special materials are available on request. Optimum installation solutions with retractable assembly technology or permanent installations pH measurement is one of the most important online analysis methods in the chemical industry. The monitoring, accuracy and maintenance of the pH value in the production plants is a guarantee for optimized product...

Open the catalog to page 4
pH measuring technology, Sensors, assemblies and transmitters for all applications - 5

Mycom S CPM153 Mycom S CPM153 Liquiline M CM42 Monitoring functions for electrode slope, zero point, membrane glass impedance and diaphragm resistance Օ Two-wire transmitter with large, high-contrast display and red alarm LED Plastic housing with handy keys, IP 67 Օ Newly developed process check system Flexible module concept, fast replacement or extension even in hazardous applications Օ Logbook functions for calibrations, pH value, alarms and operating commands Optimum diagnosis module Օ Menu navigation and configuration via navigator, intuitive operation thanks to plain text messages and...

Open the catalog to page 5
pH measuring technology, Sensors, assemblies and transmitters for all applications - 6

Retractable assemblies Cleanfit CPA475 and CPA465 > Very high demands are made on a measuring point in the food and pharmaceutical industries with regard to hygiene and cleanability. Endress+Hauser offers a wide range of special pH sensors for this purpose which are characterized by optimum cleanability, a high number of CIP and SIP cycles and the possibility of autoclaving. In addition, special pH sensors have a certified biocompatibility to ISO standard which guarantees that only biologically safe materials are in direct contact with the medium. As an additional product safety element,...

Open the catalog to page 6
pH measuring technology, Sensors, assemblies and transmitters for all applications - 7

Mycom S CPM153 Liquiline M CM42Liquisys M CPM253 Liquisys M CPM223 Tophit CPS441D Liquisys M CPM223/253 Mycom S CPM153 Liquiline M CM42 Simple to operate: clear menu structure with plain language in 6 languages makes configuration easier Օ The ideal supplement for standard glass electrodes and ISFET pH sensors with plain text operation Two-wire transmitter with large, high-contrast display and red alarm LED Օ Stainless steel housing with membrane keypad, hygienic design, IP 67 Large two-line display allows simultaneous display of measured value and temperature Օ High safety and certainty of...

Open the catalog to page 7
pH measuring technology, Sensors, assemblies and transmitters for all applications - 8

The treatment of drinking water or wastewater always involves monitoring regulated processes. As a result, the pH value is one of the most important measured variables in all stages of the process as both a value determining the quality of the water and as a controlled variable which has a direct effect on the economic efficiency of the plant. Dipfit CPA111 immersion assembly > Cleanfit CPA473 retractable assembly Dipfit CYA611 immersion assembly Automation even for difficult processes Օ 3 possible ways of securing unit: wall mounting, suspension bracket, pendulum mounting Flexible...

Open the catalog to page 8
pH measuring technology, Sensors, assemblies and transmitters for all applications - 9

Liquisys M CPM223/253 Simple to operate: clear menu structure with plain language in 6 languages makes configuration easier Օ Large two-line display allows simultaneous display of measured value and temperature Ultra simple two-point calibration via the CAL key Օ Safe to operate: overvoltage protection (high-voltage protector) to EN 61000-4-5 Directly accessible manual control of contacts Օ Calibration plausibility check Customized alarm configuration for fault-signaling contact and error current Օ Automatic start of cleaning following alarm or limit value overshoot Sensor check system for...

Open the catalog to page 9
pH measuring technology, Sensors, assemblies and transmitters for all applications - 10

Topcal S The fully automated Topcal S system for greater demands provides reliable measurement results with a minimum amount of maintenance particularly in aggressive and highly contaminated media as often occur in chemical processes. With Topcal S, you can clean and calibrate fully automatically outside the process. Maintenance work is reduced to changing the electrodes and buffer as well as the cleaning solution. CYC310 cabinet for Topcal S or Topclean S > Chemoclean Continuous maintenance of the sensor guarantees a high degree of accuracy and the highest degree of availability of a pH...

Open the catalog to page 10
pH measuring technology, Sensors, assemblies and transmitters for all applications - 11

Topcal S CPC310Topclean S CPC30Chemoclean Calibration Օ Sterilization Cleaning Օ Sterilization Cleaning Օ Rinsing Cleaning Օ RinsingpH measuring point with automatic cleaning system RinsingFully automatic pH measuring point with integrated control Quality pH buffer CPY20 Quality buffers for calibration and adjustment of pH electrodes Your benefits Օ 7 different buffers available (2, 4, 7, 9, 9.2, 10, 12) Traceable to reference material of PTB and standard reference material of NIST Cleanfit CPA475 Sterilizable retractable assembly for the highest hygienic requirements Fully automatic pH...

Open the catalog to page 11

All Endress+Hauser AG catalogs and technical brochures

  1. FTL41

    3 Pages

  2. FTL51B

    6 Pages

  3. FMG50

    10 Pages

  4. PTP31B

    3 Pages

  5. CUS71D

    3 Pages

  6. iTEMP TMT162

    3 Pages

  7. CLS54D

    3 Pages

  8. CLS50D

    3 Pages

  9. FMX21

    5 Pages

  10. iTHERM TM401

    3 Pages

  11. COS61D

    3 Pages

  12. FMD72

    5 Pages

  13. PMP51

    7 Pages

  14. FMD78

    8 Pages

  15. PMD75

    10 Pages

  16. FMI51

    4 Pages

  17. FMU30

    7 Pages

  18. FMP57

    4 Pages

  19. FMP55

    4 Pages

  20. FMP54

    5 Pages

  21. FMP51

    5 Pages

  22. FMP50

    4 Pages

  23. FMR52

    4 Pages

  24. FMR51

    5 Pages

  25. F 200

    13 Pages

  26. D 200

    12 Pages

  27. E 100

    5 Pages

  28. C 200

    11 Pages

  29. B_unit4_1

    1 Pages

  30. B_unit3_3

    1 Pages

  31. B_unit3_2

    1 Pages

  32. Wort cooler

    1 Pages

Archived catalogs