Catalog excerpts
iTEMP TMT162 Temperature field transmitter Electronic monitoring, conversion and display of input signals - all over the industries F High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics Backlit display with large measured value, bar graph and status condition indication Diagnostics information according to NAMUR NE107 International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approval SIL certification as per IEC 61508:2010 Galvanic isolation 2 kV (sensor input / current output) More information and current pricing: www.endress.com/TMT162 Accuracy (Pt100, -50...200 °C) <= 0,15 K (HART) (Pt100, -58...392 °F) <= 0,3 °F (HART) (Pt100) <= 0,1 K (FF, PA) (Pt100) <= 0,18 °F (FF, PA) Field of application: Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PAcommunication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Open the catalog to page 1Temperature transmitters Measuring principle Field transmitter Input FOUNDATION Fieldbus H1 PROFIBUS PA Auxiliary power supply 11,5...42 V DC Ex ia: 11,5...30 V DC FOUNDATION Fieldbus: 9...32 V DC Ex ia: 10,5...24 V DC PROFIBUS PA: 9...32 V DC Ex ia: 10,5...24 V DC Communication FOUNDATION Fieldbus PROFIBUS PA Installation (Pt100, -50...200 °C) <= 0,15 K (HART) (Pt100, -58...392 °F) <= 0,3 °F (HART) (Pt100) <= 0,1 K (FF, PA) (Pt100) <= 0,18 °F (FF, PA) Galvanic isolation
Open the catalog to page 2Temperature transmitters UL rec. Comp FM IS, NI I/1+2/ABCD CSA IS, NI I/1+2/ABCD ATEX II1G Ex ia IIC T6 ATEX II2G Ex d IIC T6 ATEX II3G Ex nA IIC T6 ATEX II3G Ex ic IIC T6 ATEX IECEx II2D Ex tb IIIC Db ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC FM XP, NI, DIP I,II,III/1+2/A-G CSA XP, NI, DIP I,II,III/1+2/A-G FM XP, DIP, IS, NI I,II,III/1+2/A-G CSA XP, DIP, IS, NI I,II,III/1+2/A-G FM+CSA XP,DIP, IS, NI I,II,III/1+2/A-G CSA General Purpose IECEx Ex d IIC T6 Gb IECEx Ex ia, Ex d NEPSI Ex ia IIC T4-T6 NEPSI Ex nA II T4-T6 NEPSI Ex d IIC T4-T6 TIIS Ex ia IIC T4 TIIS Ex ia IIC T6 TIIS Ex d IIC T6...
Open the catalog to page 3All Endress+Hauser AG catalogs and technical brochures
-
FTL41
3 Pages
-
FTL51B
6 Pages
-
FMG50
10 Pages
-
PTP31B
3 Pages
-
Proline Promass E 300
13 Pages
-
CUS71D
3 Pages
-
CLS54D
3 Pages
-
CLS50D
3 Pages
-
FMX21
5 Pages
-
Liquipoint FTW23
3 Pages
-
Deltapilot FMB50
7 Pages
-
iTHERM TM401
3 Pages
-
COS61D
3 Pages
-
Proline Promag 10W
4 Pages
-
Proline Promag 10P
4 Pages
-
Liquiphant FTL51
6 Pages
-
FMD72
5 Pages
-
PMP51
7 Pages
-
Cerabar PMC51
7 Pages
-
Cerabar PMP75
8 Pages
-
Proline t-mass B 150
4 Pages
-
Proline Prosonic Flow 93P
5 Pages
-
Proline Prosonic Flow 92F
4 Pages
-
FMD78
8 Pages
-
PMD75
10 Pages
-
FMI51
4 Pages
-
FMU30
7 Pages
-
FMP57
4 Pages
-
FMP55
4 Pages
-
FMP54
5 Pages
-
FMP51
5 Pages
-
FMP50
4 Pages
-
FMR52
4 Pages
-
FMR51
5 Pages
-
F 200
13 Pages
-
D 200
12 Pages
-
E 100
5 Pages
-
C 200
11 Pages
-
Tophit CPS471 and CPS471D
20 Pages
-
Tophit CPS491 and CPS491D
20 Pages
-
B_unit4_1
1 Pages
-
B_unit3_3
1 Pages
-
B_unit3_2
1 Pages
-
Wort cooler
1 Pages
-
Condumax CLS16 and CLS16D
14 Pages
-
Condumax CLS16D/CLS16
16 Pages
-
Competence in Oil and Gas
30 Pages
-
Pressure Transducer CT40
24 Pages
-
Liquiphant T FTL20
20 Pages
-
Gammapilot M FMG60
48 Pages
-
Deltabar S PMD70
96 Pages
-
Deltapilot S FMB70
56 Pages
-
Liquicap T FMI21
40 Pages
-
Prosonic S FDU91
40 Pages
-
Levelflex M FMP40
72 Pages
-
Micropilot FMR50
76 Pages
Archived catalogs
-
System components
20 Pages
-
Flow Measurement