iTEMP TMT162 Temperature field transmitter Electronic monitoring, conversion and display of input signals - all over the industries F High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics Backlit display with large measured value, bar graph and status condition indication Diagnostics information according to NAMUR NE107 International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approval SIL certification as per IEC 61508:2010 Galvanic isolation 2 kV (sensor input / current output) More information and current pricing: www.endress.com/TMT162 Accuracy (Pt100, -50...200 °C) <= 0,15 K (HART) (Pt100, -58...392 °F) <= 0,3 °F (HART) (Pt100) <= 0,1 K (FF, PA) (Pt100) <= 0,18 °F (FF, PA) Field of application: Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PAcommunication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Open the catalog to page 1Temperature transmitters Measuring principle Field transmitter Input FOUNDATION Fieldbus H1 PROFIBUS PA Auxiliary power supply 11,5...42 V DC Ex ia: 11,5...30 V DC FOUNDATION Fieldbus: 9...32 V DC Ex ia: 10,5...24 V DC PROFIBUS PA: 9...32 V DC Ex ia: 10,5...24 V DC Communication FOUNDATION Fieldbus PROFIBUS PA Installation (Pt100, -50...200 °C) <= 0,15 K (HART) (Pt100, -58...392 °F) <= 0,3 °F (HART) (Pt100) <= 0,1 K (FF, PA) (Pt100) <= 0,18 °F (FF, PA) Galvanic isolation
Open the catalog to page 2Temperature transmitters UL rec. Comp FM IS, NI I/1+2/ABCD CSA IS, NI I/1+2/ABCD ATEX II1G Ex ia IIC T6 ATEX II2G Ex d IIC T6 ATEX II3G Ex nA IIC T6 ATEX II3G Ex ic IIC T6 ATEX IECEx II2D Ex tb IIIC Db ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC FM XP, NI, DIP I,II,III/1+2/A-G CSA XP, NI, DIP I,II,III/1+2/A-G FM XP, DIP, IS, NI I,II,III/1+2/A-G CSA XP, DIP, IS, NI I,II,III/1+2/A-G FM+CSA XP,DIP, IS, NI I,II,III/1+2/A-G CSA General Purpose IECEx Ex d IIC T6 Gb IECEx Ex ia, Ex d NEPSI Ex ia IIC T4-T6 NEPSI Ex nA II T4-T6 NEPSI Ex d IIC T4-T6 TIIS Ex ia IIC T4 TIIS Ex ia IIC T6 TIIS Ex d IIC T6 Marine...
Open the catalog to page 33 Pages
6 Pages
10 Pages
3 Pages
13 Pages
3 Pages
3 Pages
3 Pages
5 Pages
3 Pages
7 Pages
3 Pages
3 Pages
4 Pages
4 Pages
6 Pages
5 Pages
7 Pages
7 Pages
8 Pages
4 Pages
5 Pages
4 Pages
8 Pages
10 Pages
4 Pages
7 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
5 Pages
13 Pages
12 Pages
5 Pages
11 Pages
20 Pages
20 Pages
1 Page
1 Page
1 Page
1 Page
14 Pages
16 Pages
30 Pages
24 Pages
20 Pages
96 Pages
48 Pages
40 Pages
56 Pages
40 Pages
76 Pages
72 Pages
32 Pages
20 Pages