Catalog excerpts
Guided radar measurement Time-of-Flight Levelflex FMP57 The standard sensor for highest demands for level measurement in bulk solids F Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Highest reliability due to new Multi-Echo Tracking evaluation Hardware and software developed according to IEC 61508 up to SIL3 Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system) World's easiest proof test for SIL and WHG saves time and costs More information and current pricing: www.endress.com/FMP57 Accuracy Rod probe: +/- 2 mm (0.08 in) Rope probe <= 15 m (49ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49ft): +/- 10 mm (0,39 in) Process temperature -40...+150 °C (-40...+302 °F) Process pressure absolute / max. overpressure limit Vacuum...16 bar (Vacuum...232 psi) Max. measurement distance Rod: 4 m (13 ft) Min DK>1.4 Rope: 20 m...25 m (66 ft...82 ft) Min DK >1.4; 25 m...30 m (82ft...98 ft) Min DK >1.6; 30 m...45 m (98ft...148 ft) Min DK>1,9 Main wetted parts Rod probe: 316Ti, 316L, PEEK, PPS Rope probe: 304, 316, 316
Open the catalog to page 1Field of application: Levelflex FMP57 is the sensor for the highest demands in bulk solids and best suited for measurements in high silos, bunkers or stockpiles. Providing rope probes up to a length of 45m the FMP57 is also suited to measurements in high silos. Levelflex FMP57 guided radar is used for continuous level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement. Features and specifications Continuous / Solids Measuring principle Guided radar Characteristic / Application Premium device for pulling...
Open the catalog to page 2Continuous / Solids Ambient temperature -40...+150 °C (-40...+302 °F) Process pressure absolute / max. overpressure limit Vacuum...16 bar (Vacuum...232 psi) Main wetted parts Rod probe: 316Ti, 316L, PEEK, PPS Rope probe: 304, 316, 316Ti, 316L, PEEK, PPS, PA Process connection Rod probe: 4 m (13 ft) Rope probe: 45 m (148 ft) Max. measurement distance
Open the catalog to page 3Continuous / Solids 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex Safety approvals Sensor remote with 3 m/ 9 ft cable, Remote operation via SmartBlue App using Bluetooth® addresses.endress.com info@endress.com
Open the catalog to page 4All Endress+Hauser AG catalogs and technical brochures
-
FTL41
3 Pages
-
FTL51B
6 Pages
-
FMG50
10 Pages
-
PTP31B
3 Pages
-
Proline Promass E 300
13 Pages
-
CUS71D
3 Pages
-
iTEMP TMT162
3 Pages
-
CLS54D
3 Pages
-
CLS50D
3 Pages
-
FMX21
5 Pages
-
Liquipoint FTW23
3 Pages
-
Deltapilot FMB50
7 Pages
-
iTHERM TM401
3 Pages
-
COS61D
3 Pages
-
Proline Promag 10W
4 Pages
-
Proline Promag 10P
4 Pages
-
Liquiphant FTL51
6 Pages
-
FMD72
5 Pages
-
PMP51
7 Pages
-
Cerabar PMC51
7 Pages
-
Cerabar PMP75
8 Pages
-
Proline t-mass B 150
4 Pages
-
Proline Prosonic Flow 93P
5 Pages
-
Proline Prosonic Flow 92F
4 Pages
-
FMD78
8 Pages
-
PMD75
10 Pages
-
FMI51
4 Pages
-
FMU30
7 Pages
-
FMP55
4 Pages
-
FMP54
5 Pages
-
FMP51
5 Pages
-
FMP50
4 Pages
-
FMR52
4 Pages
-
FMR51
5 Pages
-
F 200
13 Pages
-
D 200
12 Pages
-
E 100
5 Pages
-
C 200
11 Pages
-
Tophit CPS471 and CPS471D
20 Pages
-
Tophit CPS491 and CPS491D
20 Pages
-
B_unit4_1
1 Pages
-
B_unit3_3
1 Pages
-
B_unit3_2
1 Pages
-
Wort cooler
1 Pages
-
Condumax CLS16 and CLS16D
14 Pages
-
Condumax CLS16D/CLS16
16 Pages
-
Competence in Oil and Gas
30 Pages
-
Pressure Transducer CT40
24 Pages
-
Liquiphant T FTL20
20 Pages
-
Gammapilot M FMG60
48 Pages
-
Deltabar S PMD70
96 Pages
-
Deltapilot S FMB70
56 Pages
-
Liquicap T FMI21
40 Pages
-
Prosonic S FDU91
40 Pages
-
Levelflex M FMP40
72 Pages
-
Micropilot FMR50
76 Pages
Archived catalogs
-
System components
20 Pages
-
Flow Measurement
32 Pages