Guided radar measurement Time-of-Flight Levelflex FMP54 For high temperature and high pressure applications in the oil & gas, chemical and power industry F Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Highest reliability due to new Multi-Echo Tracking evaluation Hardware and software developed according to IEC 61508 up to SIL3 Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system) World's easiest proof test for SIL and WHG saves time and costs More information and current pricing: www.endress.com/FMP54 Accuracy Rod probe: +/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in) Process temperature XT: -196...+280 °C (-321...+536 °F) HT: -196...+450 °C (-321...+842 °F) Process pressure absolute / max. overpressure limit Vacuum...400 bar (Vacuum...5800 psi) Max. measurement distance Rod: 10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK >1,9 Coaxial prob
Open the catalog to page 1Main wetted parts Rod probe: 304, 316L, Alloy C, Ceramic Rope probe: 304, 316, 316L, Alloy C, Ceramic Coaxial probe: 304, 316L, Alloy C, Ceramic Field of application: Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement...
Open the catalog to page 2Continuous / Liquids Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional) Accuracy Rod probe: +/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in) Ambient temperature XT: -196...+280 °C (-321...+536 °F) HT: -196...+450 °C (-321...+842 °F) Process pressure absolute / max. overpressure limit Vacuum...400 bar (Vacuum...5800 psi) Main wetted parts Rod probe: 304, 316L, Alloy C, Ceramic Rope probe: 304, 316, 316L, Alloy C,...
Open the catalog to page 3Continuous / Liquids Process connection Thread: G 1 1/2, MNPT 1 1/2 Flange: ASME 2"...4", DN50...DN100, JIS 10K, 63K, Fisher Masoneilan Sensor length Rod probe: 10 m (33 ft) Rope probe: 45 m (148 ft) Coaxial probe: 6 m (20 ft) Max. measurement distance Rod: 10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK >1,9 Coaxial probe: 6 m (20 ft) Min DK>1.4 Communication 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex Safety approvals...
Open the catalog to page 4Continuous / Liquids Design approvals EN 10204-3.1 NACE MR0175, MR0103 ASME B31.1, B31.3 AD2000 Steam boiler approval Marine approval Sensor remote with 3 m/ 9 ft cable, Remote operation via SmartBlue App using Bluetooth® Application limits Application limits addresses.endress.com [email protected]
Open the catalog to page 53 Pages
6 Pages
10 Pages
3 Pages
13 Pages
3 Pages
3 Pages
3 Pages
3 Pages
5 Pages
3 Pages
7 Pages
3 Pages
3 Pages
4 Pages
4 Pages
6 Pages
5 Pages
7 Pages
7 Pages
8 Pages
4 Pages
5 Pages
4 Pages
8 Pages
10 Pages
4 Pages
7 Pages
4 Pages
4 Pages
5 Pages
4 Pages
4 Pages
5 Pages
13 Pages
12 Pages
5 Pages
11 Pages
20 Pages
20 Pages
1 Page
1 Page
1 Page
1 Page
14 Pages
16 Pages
30 Pages
24 Pages
20 Pages
96 Pages
48 Pages
40 Pages
56 Pages
40 Pages
76 Pages
72 Pages
32 Pages
20 Pages