Guided radar measurement Time-of-Flight Levelflex FMP51 The standard sensor for highest demands in liquid level measurement F Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Highest reliability due to new Multi-Echo Tracking evaluation Hardware and software developed according to IEC 61508 up to SIL3 Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system) World's easiest proof test for SIL and WHG saves time and costs More information and current pricing: www.endress.com/FMP51 Accuracy Rod probe :+/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in) Process temperature -50...+200 °C (-58...+392 °F) Process pressure absolute / max. overpressure limit Vacuum...40 bar (Vacuum...580 psi) Max. measurement distance Rod: 10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6; 30m...45 m (98ft...148 ft) Min DK>1,9 Coaxial probe:
Open the catalog to page 1Main wetted parts Rod probe: 316L, Alloy C, Ceramic Rope probe: 316, 316L, Alloy C, Ceramic Coaxial probe: 316L, Alloy C, Ceramic, PFA Field of application: Levelflex FMP51 for level measurement even under extreme process conditions like high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing...
Open the catalog to page 2Continuous / Liquids Supply / Communication 2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional) Accuracy Rod probe :+/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in) Ambient temperature -50...+200 °C (-58...+392 °F) Process pressure absolute / max. overpressure limit Vacuum...40 bar (Vacuum...580 psi) Main wetted parts Rod probe: 316L, Alloy C, Ceramic Rope probe: 316, 316L, Alloy C, Ceramic Coaxial probe: 316L, Alloy C, Ceramic, PFA
Open the catalog to page 3Continuous / Liquids Process connection Rod probe: 10 m (33 ft) Rope probe: 45 m (148 ft) Coaxial probe: 6 m (20 ft) Max. measurement distance Rod: 10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6; 30m...45 m (98ft...148 ft) Min DK>1,9 Coaxial probe: 6 m (20 ft) Min DK>1.4 Communication 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex Safety approvals Overfill protection WHG SIL Design approvals
Open the catalog to page 4Continuous / Liquids Marine approval Sensor remote with 3 m/ 9 ft cable, Gas-tight feed through, Remote operation via SmartBlue App using Bluetooth® Application limits Application limits addresses.endress.com [email protected]
Open the catalog to page 53 Pages
6 Pages
10 Pages
3 Pages
13 Pages
3 Pages
3 Pages
3 Pages
3 Pages
5 Pages
3 Pages
7 Pages
3 Pages
3 Pages
4 Pages
4 Pages
6 Pages
5 Pages
7 Pages
7 Pages
8 Pages
4 Pages
5 Pages
4 Pages
8 Pages
10 Pages
4 Pages
7 Pages
4 Pages
4 Pages
5 Pages
4 Pages
4 Pages
5 Pages
13 Pages
12 Pages
5 Pages
11 Pages
20 Pages
20 Pages
1 Page
1 Page
1 Page
1 Page
14 Pages
16 Pages
30 Pages
24 Pages
20 Pages
96 Pages
48 Pages
40 Pages
56 Pages
40 Pages
76 Pages
72 Pages
32 Pages
20 Pages