Guided radar measurement Time-of-Flight Levelflex FMP50 For all basic level applications in liquids F Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Highest reliability due to new Multi-Echo Tracking evaluation Hardware and software developed according to IEC 61508 up to SIL3 Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system) World's easiest proof test for SIL and WHG saves time and costs More information and current pricing: www.endress.com/FMP50 Accuracy Rod probe: +/- 2 mm (0.08 in) Rope probe: +/- 2 mm (0.08 in) Process temperature -20...+80 °C (-4...+176 °F) Process pressure absolute / max. overpressure limit Vacuum...6 bar, (Vacuum...87 psi) Max. measurement distance Rod: 4 m (13 ft) Min DK>1.6 Rope: 12 m (40 ft) Min DK>1.6 Main wetted parts Rod probe: 316L, PPS, Viton Rope probe: 316, PPS, Viton Field of application: Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FM
Open the catalog to page 1Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. Features and specifications Continuous / Liquids Measuring principle Guided radar Characteristic / Application Basic device Rod probe, Rope probe Integrated data memory, Factory precalibrated, Reliable measuring for changing medias. Specialities Heartbeat Technology, Bluetooth® commissioning, Operation and maintenance SmartBlue App, HistoROM, RFID TAG for easy identification Supply /...
Open the catalog to page 2Continuous / Liquids Process pressure absolute / max. overpressure limit Vacuum...6 bar, (Vacuum...87 psi) Main wetted parts Rod probe: 316L, PPS, Viton Rope probe: 316, PPS, Viton Process connection Thread: G 3/4, MNPT 3/4 Flange: UNI Flange Sensor length Rod probe: 4 m (13 ft) Rope probe: 12 m (40 ft) Max. measurement distance 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex Safety approvals Overfill protection WHG SIL Design approvals
Open the catalog to page 3Continuous / Liquids Sensor remote with 3 m/ 9 ft cable, Remote operation via SmartBlue App using Bluetooth® Application limits Application limits addresses.endress.com info@endress.com
Open the catalog to page 4All Endress+Hauser AG catalogs and technical brochures
-
FTL41
3 Pages
-
FTL51B
6 Pages
-
FMG50
10 Pages
-
PTP31B
3 Pages
-
Proline Promass E 300
13 Pages
-
CUS71D
3 Pages
-
iTEMP TMT162
3 Pages
-
CLS54D
3 Pages
-
CLS50D
3 Pages
-
FMX21
5 Pages
-
Liquipoint FTW23
3 Pages
-
Deltapilot FMB50
7 Pages
-
iTHERM TM401
3 Pages
-
COS61D
3 Pages
-
Proline Promag 10W
4 Pages
-
Proline Promag 10P
4 Pages
-
Liquiphant FTL51
6 Pages
-
FMD72
5 Pages
-
PMP51
7 Pages
-
Cerabar PMC51
7 Pages
-
Cerabar PMP75
8 Pages
-
Proline t-mass B 150
4 Pages
-
Proline Prosonic Flow 93P
5 Pages
-
Proline Prosonic Flow 92F
4 Pages
-
FMD78
8 Pages
-
PMD75
10 Pages
-
FMI51
4 Pages
-
FMU30
7 Pages
-
FMP57
4 Pages
-
FMP55
4 Pages
-
FMP54
5 Pages
-
FMP51
5 Pages
-
FMR52
4 Pages
-
FMR51
5 Pages
-
F 200
13 Pages
-
D 200
12 Pages
-
E 100
5 Pages
-
C 200
11 Pages
-
Tophit CPS471 and CPS471D
20 Pages
-
Tophit CPS491 and CPS491D
20 Pages
-
B_unit4_1
1 Pages
-
B_unit3_3
1 Pages
-
B_unit3_2
1 Pages
-
Wort cooler
1 Pages
-
Condumax CLS16 and CLS16D
14 Pages
-
Condumax CLS16D/CLS16
16 Pages
-
Competence in Oil and Gas
30 Pages
-
Pressure Transducer CT40
24 Pages
-
Liquiphant T FTL20
20 Pages
-
Gammapilot M FMG60
48 Pages
-
Deltabar S PMD70
96 Pages
-
Deltapilot S FMB70
56 Pages
-
Liquicap T FMI21
40 Pages
-
Prosonic S FDU91
40 Pages
-
Levelflex M FMP40
72 Pages
-
Micropilot FMR50
76 Pages
Archived catalogs
-
System components
20 Pages
-
Flow Measurement
32 Pages