FMG50
10Pages

{{requestButtons}}

Catalog excerpts

FMG50 - 1

Radiometric level and density measurement Gammapilot FMG50 Compact transmitter for point level detection, continuous level, interface and density measurement F More information and current pricing: First real 2-wire loop-powered compact transmitter minimizes engineering and installation efforts Reduced installation and engineering costs thanks to the first 2-wire loop powered compact transmitter Increased plant safety, efficiency and availability even under extreme process and ambient conditions Designed according to IEC 61508 with SIL2/3 approval for all measuring tasks Reduced verification effort and minimized plant shut-downs due to state-of-art Heartbeat Technology Usage in up to +80°C (+176°F) ambient temperature without additional cooling thanks to innovative sensor technology Bluetooth® wireless technology for remote operation out of the radiation beam Process temperature Any Process pressure absolute / max. overpressure limit Any Max. measurement distance Unlimited measuring range, Cascade Accuracy +/-1% Main wetted parts Non-contact Field of application: The Gammapilot FMG50 compact transmitter is designed for non-contact point level detection, continuous level, interface and density measurement in liquids

Open the catalog to page 1
FMG50 - 2

sludges. As the first true 2-wire loop powered compact transmitter it minimizes engineering and installation efforts. Features and specifications Continuous / Solids Measuring principle Radiometric Characteristic / Application Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique Specialities Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App Supply / Communication 2-wire loop powered Accuracy Any Process pressure absolute / max. overpressure limit Any Main...

Open the catalog to page 2
FMG50 - 3

Continuous / Solids Process connection Non-contact Sensor length PVT scintillator 400 mm...3000 mm, >3000 mm cascade mode Max. measurement distance Unlimited measuring range, Cascade Communication 4...20 mA HART Certificates / Approvals ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex Safety approvals Overfill protection WHG SIL 2/3 Design approvals Display Components Point Level / Solids Measuring principle Radiometric Limit

Open the catalog to page 3
FMG50 - 4

Point Level / Solids Characteristic / Application Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique Specialities Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App Supply / Communication 2-wire loop powered Ambient temperature Any Process pressure absolute / max. overpressure limit Any Main wetted parts Non-contact Process connection Non-contact Sensor length PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm Communication

Open the catalog to page 4
FMG50 - 5

Point Level / Solids Certificates / Approvals ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex Safety approvals Overfill protection WHG SIL 2/3 Design approvals Display Components Measuring principle Radiometric Density Characteristic / Application Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique Supply / Communication 2-wire loop powered Ambient temperature

Open the catalog to page 5
FMG50 - 6

Process pressure absolute Non-contact Sensor length PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm Output 4...20 mA HART Certificates / Approvals ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex Options Display Specialities Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App Components Continuous / Liquids Measuring principle

Open the catalog to page 6
FMG50 - 7

Continuous / Liquids Characteristic / Application Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique Interface measurement Interfaces liquid / liquid also with emulsion layers Interfaces liquid / solid Specialities Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App Supply / Communication 2-wire loop powered Accuracy Any Process pressure absolute / max. overpressure limit Any Main wetted parts Non-contact Process connection

Open the catalog to page 7
FMG50 - 8

Continuous / Liquids Sensor length PVT scintillator 400 mm...3000 mm, >3000 mm cascade mode Max. measurement distance Unlimited measuring range, Cascade Communication 4...20 mA HART Certificates / Approvals ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex Safety approvals Overfill protection WHG SIL 2/3 Design approvals Display Components Point Level / Liquids Measuring principle Radiometric Limit Characteristic / Application Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique

Open the catalog to page 8
FMG50 - 9

Point Level / Liquids Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App Supply / Communication 2-wire loop powered Ambient temperature Any Process pressure absolute / max. overpressure limit Any Main wetted parts Non-contact Process connection Non-contact Sensor length PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm Communication 4...20 mA HART Certificates / Approvals ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Open the catalog to page 9
FMG50 - 10

Point Level / Liquids Safety approvals Overfill protection WHG SIL 2/3 Design approvals Display Components addresses.endress.com info@endress.com

Open the catalog to page 10

All Endress+Hauser AG catalogs and technical brochures

  1. FTL41

    3 Pages

  2. FTL51B

    6 Pages

  3. PTP31B

    3 Pages

  4. CUS71D

    3 Pages

  5. iTEMP TMT162

    3 Pages

  6. CLS54D

    3 Pages

  7. CLS50D

    3 Pages

  8. FMX21

    5 Pages

  9. iTHERM TM401

    3 Pages

  10. COS61D

    3 Pages

  11. FMD72

    5 Pages

  12. PMP51

    7 Pages

  13. FMD78

    8 Pages

  14. PMD75

    10 Pages

  15. FMI51

    4 Pages

  16. FMU30

    7 Pages

  17. FMP57

    4 Pages

  18. FMP55

    4 Pages

  19. FMP54

    5 Pages

  20. FMP51

    5 Pages

  21. FMP50

    4 Pages

  22. FMR52

    4 Pages

  23. FMR51

    5 Pages

  24. F 200

    13 Pages

  25. D 200

    12 Pages

  26. E 100

    5 Pages

  27. C 200

    11 Pages

  28. B_unit4_1

    1 Pages

  29. B_unit3_3

    1 Pages

  30. B_unit3_2

    1 Pages

  31. Wort cooler

    1 Pages

Archived catalogs