F 200 - 1

Proline Prowirl F 200 vortex flowmeter Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy F Easy energy management – integrated temperature and pressure measurement for steam and gases Space-saving engineering – inlet run compensation Same accuracy down to Re 10 000 – most linear Vortex meter body Long-term stability – robust drift-free capacitive sensor Convenient device wiring – separate connection compartment Safe operation – no need to open the device due to display with touch control, background lighting Integrated verification – Heartbeat Technology More information and current pricing: www.endress.com/7F2C Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/ pressure compensated) Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation) Mass flow (liquid): ±0.85% Measuring range Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/ min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) Medium temperature range Standard: –40 to +260 °C (–40 to +500 °F) High/low

Open the catalog to page 1
F 200 - 2

Max. process pressure PN 100, Class 600, 20K Wetted materials Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602 Process connection: 1.4404/F316/F316L); 2.4602 Field of application: Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration...

Open the catalog to page 2
F 200 - 3

Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). Nominal diameter range Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602 Process connection: 1.4404/F316/F316L); 2.4602 Measured variables Volume flow,...

Open the catalog to page 3
F 200 - 4

PN 100, Class 600, 20K Medium temperature range Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) Ambient temperature range Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) Sensor housing material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) Transmitter housing material AlSi10Mg, coated; 1.4404 (316L) Degree of protection Compact version:...

Open the catalog to page 4
F 200 - 5

Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus Power supply DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) Hazardous area approvals ATEX, IECEx, cCSAus, JPN, EAC, UK Ex Product safety CE, C-TICK, EAC Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 Metrological approvals and certificates Calibration...

Open the catalog to page 5
F 200 - 6

Measuring principle Vortex Product headline Versatile flowmeter with detection of wet steam conditions and best-inclass accuracy. Easy energy management – integrated temperature and pressure measurement for steam and gases. Suitable for a wide range of applications; optimized for steam applications. Sensor features Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial...

Open the catalog to page 6
F 200 - 7

Nominal diameter range Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602 Process connection: 1.4404/F316/F316L); 2.4602 Measured variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) Mass flow (superheated steam, gas): ±1.5...

Open the catalog to page 7
F 200 - 8

Ambient temperature range Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) Sensor housing material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) Transmitter housing material AlSi10Mg, coated; 1.4404 (316L) Degree of protection Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure Display/Operation 4‐line...

Open the catalog to page 8

All Endress+Hauser AG catalogs and technical brochures

  1. FTL41

    3 Pages

  2. FTL51B

    6 Pages

  3. FMG50

    10 Pages

  4. PTP31B

    3 Pages

  5. CUS71D

    3 Pages

  6. iTEMP TMT162

    3 Pages

  7. CLS54D

    3 Pages

  8. CLS50D

    3 Pages

  9. FMX21

    5 Pages

  10. iTHERM TM401

    3 Pages

  11. COS61D

    3 Pages

  12. FMD72

    5 Pages

  13. PMP51

    7 Pages

  14. FMD78

    8 Pages

  15. PMD75

    10 Pages

  16. FMI51

    4 Pages

  17. FMU30

    7 Pages

  18. FMP57

    4 Pages

  19. FMP55

    4 Pages

  20. FMP54

    5 Pages

  21. FMP51

    5 Pages

  22. FMP50

    4 Pages

  23. FMR52

    4 Pages

  24. FMR51

    5 Pages

  25. D 200

    12 Pages

  26. E 100

    5 Pages

  27. C 200

    11 Pages

  28. B_unit4_1

    1 Pages

  29. B_unit3_3

    1 Pages

  30. B_unit3_2

    1 Pages

  31. Wort cooler

    1 Pages

Archived catalogs