Deltapilot FMB50 - 1

Hydrostatic Level measurement Deltapilot FMB50 Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement F Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects Modular concept for easy replacement of display or electronics Seamless and independent system integration (HART/PA/FF) Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus International usage thanks to a wide range of approvals More information and current pricing: Accuracy Standard 0.2% Optional 0.1% Process temperature -10°C...100°C (14°F...212°F) Pressure measuring range 100 mbar...10 bar (1.5 psi...150 psi) Process pressure absolute / max. overpressure limit 40 bar (600 psi) Main wetted parts Alloy C 316L optional coating AuPt Field of application: The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.

Open the catalog to page 1
Deltapilot FMB50 - 2

Measuring principle Hydrostatic pressure Characteristic Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Supply voltage 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) Reference Accuracy Standard 0.2 % Optional 0.1 % Long term stability 0.05 % of URL/ year Process temperature 100 mbar...10 bar (1.5 psi...150 psi) Smallest calibratable span

Open the catalog to page 2
Deltapilot FMB50 - 3

Vacuum resistance 0 mbar abs. Max. Turn down Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD Material process membrane 316L, AlloyC Gold-Rhodium Material gasket None, measuring cell welded Fill fluid

Open the catalog to page 3
Deltapilot FMB50 - 4

Material housing 316L, Die-cast aluminum Communication 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI Safety approvals Overfill protection WHG SIL Design approvals EN10204-3.1 NACE MR0103 Hygienic approvals 3A, EHEDG CoC ASME-BPE Marine approvals GL/ ABS/ LR/ BV/ DNV Drinking water approvals Modularity to differential pressure and process pressure devices (replacable display, universal electronics) Diagnostic functions Continuous / Liquids Measuring principle

Open the catalog to page 4
Deltapilot FMB50 - 5

Continuous / Liquids Characteristic / Application Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics) Diagnostic functions Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed) Supply / Communication 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) Accuracy...

Open the catalog to page 5
Deltapilot FMB50 - 6

Continuous / Liquids Pressure measuring range 100 mbar...10 bar (1.5 psi...150 psi) Main wetted parts Alloy C 316L optional coating AuPt Process connection Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD Max. measurement distance 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Open the catalog to page 6
Deltapilot FMB50 - 7

Continuous / Liquids Safety approvals Overfill protection WHG SIL Design approvals EN10204-3.1 NACE MR0103 Hygienic approvals 3A, EHEDG CoC ASME-BPE Marine approval GL/ ABS/ LR/ BV/ DNV Drinking water approvals Separate housing Initial device settings Overvoltage protection Application limits If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure addresses.endress.com info@endress.com

Open the catalog to page 7

All Endress+Hauser AG catalogs and technical brochures

  1. FTL41

    3 Pages

  2. FTL51B

    6 Pages

  3. FMG50

    10 Pages

  4. PTP31B

    3 Pages

  5. CUS71D

    3 Pages

  6. iTEMP TMT162

    3 Pages

  7. CLS54D

    3 Pages

  8. CLS50D

    3 Pages

  9. FMX21

    5 Pages

  10. iTHERM TM401

    3 Pages

  11. COS61D

    3 Pages

  12. FMD72

    5 Pages

  13. PMP51

    7 Pages

  14. FMD78

    8 Pages

  15. PMD75

    10 Pages

  16. FMI51

    4 Pages

  17. FMU30

    7 Pages

  18. FMP57

    4 Pages

  19. FMP55

    4 Pages

  20. FMP54

    5 Pages

  21. FMP51

    5 Pages

  22. FMP50

    4 Pages

  23. FMR52

    4 Pages

  24. FMR51

    5 Pages

  25. F 200

    13 Pages

  26. D 200

    12 Pages

  27. E 100

    5 Pages

  28. C 200

    11 Pages

  29. B_unit4_1

    1 Pages

  30. B_unit3_3

    1 Pages

  31. B_unit3_2

    1 Pages

  32. Wort cooler

    1 Pages

Archived catalogs