Proline Prowirl D 200 vortex flowmeter Cost-effective wafer flowmeter, available as compact or remote version F Integrated temperature measurement for mass/energy flow of saturated steam Easy alignment of the sensor – included centering rings High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer Long-term stability – robust drift-free capacitive sensor Convenient device wiring – separate connection compartment Safe operation – no need to open the device due to display with touch control, background lighting Integrated verification – Heartbeat Technology Specs at a glance More information and current pricing: Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 % Measuring range Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) Medium temperature range Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) Max. process pressure PN 40, Class 300, 20K Wetted mate
Open the catalog to page 1Field of application: The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine looppowered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology ensures process safety at all times. Features and specifications Liquids Measuring principle Vortex Product headline Cost-effective wafer flowmeter, available as compact or remote version....
Open the catalog to page 2Wetted materials Measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L) Measured variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 % Measuring range Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25...
Open the catalog to page 3Transmitter housing material AlSi10Mg, coated; 1.4404 (316L) Degree of protection Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure Display/Operation 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available Outputs 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) Inputs Current input 4‐20 mA (passive) Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus Power...
Open the catalog to page 4Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) Marine approvals and certificates ABS, LR, BV, DNV GL Pressure approvals and certificates 3.1 material NACE MR0175/MR0103, PMI (on request) Measuring principle Vortex Product headline...
Open the catalog to page 5Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). Nominal diameter range Measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L) Measured variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature Max. measurement error Volume flow...
Open the catalog to page 6Ambient temperature range Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) Sensor housing material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) Transmitter housing material AlSi10Mg, coated; 1.4404 (316L) Degree of protection Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure Display/Operation 4‐line...
Open the catalog to page 7Power supply DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) Hazardous area approvals ATEX, IECEx, cCSAus, JPN, EAC, UK Ex Product safety CE, C-TICK, EAC Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC...
Open the catalog to page 8Product headline Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates. Sensor features Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. Transmitter features Convenient device wiring – separate...
Open the catalog to page 9All Endress+Hauser AG catalogs and technical brochures
-
FTL41
3 Pages
-
FTL51B
6 Pages
-
FMG50
10 Pages
-
PTP31B
3 Pages
-
Proline Promass E 300
13 Pages
-
CUS71D
3 Pages
-
iTEMP TMT162
3 Pages
-
CLS54D
3 Pages
-
CLS50D
3 Pages
-
FMX21
5 Pages
-
Liquipoint FTW23
3 Pages
-
Deltapilot FMB50
7 Pages
-
iTHERM TM401
3 Pages
-
COS61D
3 Pages
-
Proline Promag 10W
4 Pages
-
Proline Promag 10P
4 Pages
-
Liquiphant FTL51
6 Pages
-
FMD72
5 Pages
-
PMP51
7 Pages
-
Cerabar PMC51
7 Pages
-
Cerabar PMP75
8 Pages
-
Proline t-mass B 150
4 Pages
-
Proline Prosonic Flow 93P
5 Pages
-
Proline Prosonic Flow 92F
4 Pages
-
FMD78
8 Pages
-
PMD75
10 Pages
-
FMI51
4 Pages
-
FMU30
7 Pages
-
FMP57
4 Pages
-
FMP55
4 Pages
-
FMP54
5 Pages
-
FMP51
5 Pages
-
FMP50
4 Pages
-
FMR52
4 Pages
-
FMR51
5 Pages
-
F 200
13 Pages
-
E 100
5 Pages
-
C 200
11 Pages
-
Tophit CPS471 and CPS471D
20 Pages
-
Tophit CPS491 and CPS491D
20 Pages
-
B_unit4_1
1 Pages
-
B_unit3_3
1 Pages
-
B_unit3_2
1 Pages
-
Wort cooler
1 Pages
-
Condumax CLS16 and CLS16D
14 Pages
-
Condumax CLS16D/CLS16
16 Pages
-
Competence in Oil and Gas
30 Pages
-
Pressure Transducer CT40
24 Pages
-
Liquiphant T FTL20
20 Pages
-
Gammapilot M FMG60
48 Pages
-
Deltabar S PMD70
96 Pages
-
Deltapilot S FMB70
56 Pages
-
Liquicap T FMI21
40 Pages
-
Prosonic S FDU91
40 Pages
-
Levelflex M FMP40
72 Pages
-
Micropilot FMR50
76 Pages
Archived catalogs
-
System components
20 Pages
-
Flow Measurement
32 Pages