Catalog excerpts
Conductivity compact device Smartec CLD134 Toroidal conductivity measuring system for hygienic and sterile applications F Unique hygienic design avoids recontamination With all hygienic certificates required in hygienic and sterile applications Certified biocompatibility according to USP class VI Compliant with EG 2023/2006 and 1935/2004 Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP) Durable thanks to encapsulated, jointless design More information and current pricing: www.endress.com/CLD134 Measurement range 100 µS/cm to 2000 mS/cm Cell constant k : 6.3 1/cm Process temperature Max. 125 °C (max. 257 °F) For sterilization: up to 150 °C for max. 60 min (up to 302 °F for max. 60 min) Process pressure 12 bar abs up to 90 °C (174 psi abs up to 194 °F) Field of application: Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.
Open the catalog to page 1Measuring principle Inductive Application Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring Measurement range 100 µS/cm to 2000 mS/cm Cell constant k : 6.3 1/cm Measuring principle Inductive conductivity measurement Design Hygienic design with FDA certified virgin PEEK body including all hygienic certifications Material In contact with medium:...
Open the catalog to page 2Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50 Ingres protection Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus Additional certifications FDA, EHEDG, 3A Biological reactivity USP class VI part <87> and <88> EC Regulation No. 1935/2004 addresses.endress.com info@endress.com
Open the catalog to page 3All Endress+Hauser AG catalogs and technical brochures
-
FTL41
3 Pages
-
FTL51B
6 Pages
-
FMG50
10 Pages
-
PTP31B
3 Pages
-
Proline Promass E 300
13 Pages
-
CUS71D
3 Pages
-
iTEMP TMT162
3 Pages
-
CLS54D
3 Pages
-
CLS50D
3 Pages
-
FMX21
5 Pages
-
Liquipoint FTW23
3 Pages
-
Deltapilot FMB50
7 Pages
-
iTHERM TM401
3 Pages
-
COS61D
3 Pages
-
Proline Promag 10W
4 Pages
-
Proline Promag 10P
4 Pages
-
Liquiphant FTL51
6 Pages
-
FMD72
5 Pages
-
PMP51
7 Pages
-
Cerabar PMC51
7 Pages
-
Cerabar PMP75
8 Pages
-
Proline t-mass B 150
4 Pages
-
Proline Prosonic Flow 93P
5 Pages
-
Proline Prosonic Flow 92F
4 Pages
-
FMD78
8 Pages
-
PMD75
10 Pages
-
FMI51
4 Pages
-
FMU30
7 Pages
-
FMP57
4 Pages
-
FMP55
4 Pages
-
FMP54
5 Pages
-
FMP51
5 Pages
-
FMP50
4 Pages
-
FMR52
4 Pages
-
FMR51
5 Pages
-
F 200
13 Pages
-
D 200
12 Pages
-
E 100
5 Pages
-
C 200
11 Pages
-
Tophit CPS471 and CPS471D
20 Pages
-
Tophit CPS491 and CPS491D
20 Pages
-
B_unit4_1
1 Pages
-
B_unit3_3
1 Pages
-
B_unit3_2
1 Pages
-
Wort cooler
1 Pages
-
Condumax CLS16 and CLS16D
14 Pages
-
Condumax CLS16D/CLS16
16 Pages
-
Competence in Oil and Gas
30 Pages
-
Pressure Transducer CT40
24 Pages
-
Liquiphant T FTL20
20 Pages
-
Gammapilot M FMG60
48 Pages
-
Deltabar S PMD70
96 Pages
-
Deltapilot S FMB70
56 Pages
-
Liquicap T FMI21
40 Pages
-
Prosonic S FDU91
40 Pages
-
Levelflex M FMP40
72 Pages
-
Micropilot FMR50
76 Pages
Archived catalogs
-
System components
20 Pages
-
Flow Measurement
32 Pages