Catalog excerpts
Digital conductivity sensor Indumax CLS50D Memosens toroidal conductivity sensor for chemical applications F High durability and chemical resistance even under harsh conditions Dirt-repellent materials and large sensor opening avoid soiling Wide temperature range and highly resistant materials make the sensor suitable for virtual any application Reliable values thanks to active connection monitoring Easy wiring over long distances without impact on the measurement accuracy Logging of sensor-specific data for easy traceability Approved for hazardous area use More information and current pricing: Measurement range 2µS/cm to 2000 mS/cm Process temperature PEEK: max. 125°C (max. 260 °F) PFA: max. 110°C (max. 230 °F) Process pressure PEEK: max. 21 bar (max. 304.5 psi) PFA: max. 17 bar (max. 246.5 psi) Field of application: Indumax CLS50D is a digital inductive conductivity sensor for standard, hazardous and high-temperature applications. Benefit from high chemical resistance and long durability thanks to robust materials (PFA, PEEK). Moreover, it is insensitive to soiling and performs reliable and repeatable even in harsh and aggressive media. Thanks to Memosens, CLS50D combines maximum process and data integrity with simple operation. It resists corrosion and moisture and facilitates predictive maintenance.
Open the catalog to page 1Measuring principle Inductive Application Chemical industry, process Characteristic Analog or digital, inductive conductivity sensor for standard, Ex and high-temperature applications Measurement range 2µS/cm to 2000 mS/cm Measuring principle Inductive conductivity measurement Design No direct contact with the media because of the sensor coating made of highly resistant material Material Electrode: Outside diameter: 47.5 mm (1.87 inch) Inside diameter: 15 mm (0.59 inch) Inside diameter (PEEK version): 15.5 mm (0.61 inch) Process temperature PEEK: max. 125°C (max. 260 °F) PFA: max. 110°C...
Open the catalog to page 2ATEX, IECEx, NEPSI, FM, CSA, TIIS, EAC Connection Process connection: NPT1", DN50, AINSI, JIScable: fixed cable connection Ingres protection IP 68 / NEMA type 6 Additional certifications Calibration certification of the cell constant addresses.endress.com info@endress.com
Open the catalog to page 3All Endress+Hauser AG catalogs and technical brochures
-
FTL41
3 Pages
-
FTL51B
6 Pages
-
FMG50
10 Pages
-
PTP31B
3 Pages
-
Proline Promass E 300
13 Pages
-
CUS71D
3 Pages
-
iTEMP TMT162
3 Pages
-
CLS54D
3 Pages
-
FMX21
5 Pages
-
Liquipoint FTW23
3 Pages
-
Deltapilot FMB50
7 Pages
-
iTHERM TM401
3 Pages
-
COS61D
3 Pages
-
Proline Promag 10W
4 Pages
-
Proline Promag 10P
4 Pages
-
Liquiphant FTL51
6 Pages
-
FMD72
5 Pages
-
PMP51
7 Pages
-
Cerabar PMC51
7 Pages
-
Cerabar PMP75
8 Pages
-
Proline t-mass B 150
4 Pages
-
Proline Prosonic Flow 93P
5 Pages
-
Proline Prosonic Flow 92F
4 Pages
-
FMD78
8 Pages
-
PMD75
10 Pages
-
FMI51
4 Pages
-
FMU30
7 Pages
-
FMP57
4 Pages
-
FMP55
4 Pages
-
FMP54
5 Pages
-
FMP51
5 Pages
-
FMP50
4 Pages
-
FMR52
4 Pages
-
FMR51
5 Pages
-
F 200
13 Pages
-
D 200
12 Pages
-
E 100
5 Pages
-
C 200
11 Pages
-
Tophit CPS471 and CPS471D
20 Pages
-
Tophit CPS491 and CPS491D
20 Pages
-
B_unit4_1
1 Pages
-
B_unit3_3
1 Pages
-
B_unit3_2
1 Pages
-
Wort cooler
1 Pages
-
Condumax CLS16 and CLS16D
14 Pages
-
Condumax CLS16D/CLS16
16 Pages
-
Competence in Oil and Gas
30 Pages
-
Pressure Transducer CT40
24 Pages
-
Liquiphant T FTL20
20 Pages
-
Gammapilot M FMG60
48 Pages
-
Deltabar S PMD70
96 Pages
-
Deltapilot S FMB70
56 Pages
-
Liquicap T FMI21
40 Pages
-
Prosonic S FDU91
40 Pages
-
Levelflex M FMP40
72 Pages
-
Micropilot FMR50
76 Pages
Archived catalogs
-
System components
20 Pages
-
Flow Measurement
32 Pages