41A
3Pages

{{requestButtons}}

Catalog excerpts

41A - 1

Isotron® accelerometer MATES WITH MEGGITT x UNIT IDENTIFICATION • General purpose single axis Isotron® accelerometer • Wide frequency bandwidth • Hermetically sealed • Signal ground isolated from mounting surface • IEEE P1451.4 TEDS capable INCHES [MILLIMETERS] Model 41A is a cost effective general purpose Isotron accelerometer designed for use in a variety of applications. 41A is a small hex shaped Isotron accelerometer with a 10-32 top mount connector. The unit is hermetically sealed against environmental contamination. 41A features an annular shear ceramic crystal which exhibits excellent output stability over time. The accelerometer incorporates an internal hybrid circuit with TEDS in a two-wire IEPE system which transmits its low impedance voltage output through the same cable that supplies the constant current power. Signal ground is electrically isolated from the outer case of the unit. Polarity inversion protection for the hybrid circuit is inherent in the circuit design. 41A is available in five sensitivities designated by a two digit suffix. The 41A13 has a sensitivity of 10 mV/g respectively. The customer may select the mounting stud size included standard with the unit. The available stud sizes are 10-32, 1/4-28, M5 and M6. The stud size is designated following a dash after the model number. This product is fully compliant to the European Union's Low Voltage Directive, 2006/95/EC and EMC Directive 2004/108/EC and is Meggitt Sensing Systems Our measurement product competencies: Piezoelectric accelerometers I Piezoresistive accelerometers I Isotron accelerometerE I Variable capacitance accelerometers I Pressure transducers Acoustic sensors I Electronic instruments I Calibration systems I Shakers I Modal hammers I Cable assemblies

Open the catalog to page 1
41A - 2

Aerospace Energy Measurement Isotron® accelerometer Model 41A Specifications The following performance specifications conform to ISA-RP-37.2 and are typical values, referenced at +75°F (+24°C), 4 mA, and 100 Hz, unless otherwise noted. Calibration data, traceable to National Institute of Standards and Technology (NIST), is supplied. Dynamic characteristics Range Sensitivity ±5% ±10% Frequency response Resonance frequency Typical Minimum Amplitude response ±5% ±10% Phase response ±5º Sensitivity deviation over temperature -67ºF to +257ºF (-55ºC to +125ºC) Transverse sensitivity Amplitude...

Open the catalog to page 2
41A - 3

Aerospace Energy Measurement Isotron® accelerometer Model 41A Contact Model number definition 41A XX -YYY Meggitt Sensing Systems 14600 Myford Road Irvine CA 92606, USA Tel: +1 (949) 493 8181 Fax: +1 (949) 661 7231 Mounting stud option No dash number = No stud included - 1032 = 10-32 stud - 2528 = 1/4-28 stud - M5 = M5 stud - M6 = M6 stud www.endevco.com www.meggitt.com Denotes nominal sensitivity: 13 = 10 mV/g 14 = 25 mV/g 16 = 100 mV/g 18 = 500 mV/g 19 = 1000 mV/g Basic model number Accessories Product Optional Included Mounting stud 10-32 to 1/4-28 Optional Optional Optional Optional...

Open the catalog to page 3

All Endevco catalogs and technical brochures

  1. Model 4416C

    3 Pages

  2. Model 2510

    3 Pages

  3. 44A

    3 Pages

  4. 43A

    3 Pages

  5. 42A

    3 Pages

  6. 35B

    3 Pages

  7. 6243M3

    3 Pages

  8. 6243M1

    3 Pages

  9. 7264H

    3 Pages

Archived catalogs