ET5011
3Pages

{{requestButtons}}

Catalog excerpts

ET5011 - 1

Read this document carefully before using this device. The guarantee will be expired by damages if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages. ENDA ET5011 PID TEMPERATURE CONTROLLER Thank you for choosing ENDA ET5011 Temperature Controller 54x94mm sized. PT100 input. Auto calculation for PID parameters (SELF TUNE). Self tune for automatic PID calculation or manually enter PID parameters if known. Soft-Start feature. Zero point input shift. C1 Relay output. Selectable Heating / Cooling control. In case of sensor failure, periodically, auto-periodically running or relay state can be selected. CE Marked according to European Norms. TECHNICAL SPECIFICATIONS Input type PT100 Resistance thermometer PT100 Resistance thermometer ENVIRONMENTAL CONDITIONS Ambient/storage temperature Max. Relative humidity Rated pollution degree Height Accuracy 0,5% (of full scale) 0,5% (of full scale) 0 ... +50°C/-25... +70°C (with no icing) Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C. According to EN 60529 Front panel : IP65 Rear panel : IP20 Max. 2000m KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations. ELECTRICAL CHARACTERISTICS Supply Power consumption Wiring Line resistance Data retention 230V AC / 110V AC +%10 -%20, 50/60Hz or 24V AC ±%10, 50/60Hz 10-30V DC / 8-24V AC SMPS Max. 5VA Power connector: 2.5mm²' screw-terminal, Signal connector: 1,5mm² screw-terminal conenction. Max. 100ohm EEPROM (minimum 10 years) Safety requirements EN 61010-1: 2010 (Pollution degree 2, overvoltage category II) Life expectancy for relay Relay : 250V AC, 8A (for resistive load), Selectable as NO+NC Control output. Relay : 250V AC, 5A / 16A (for resistive load), Selectable as NO Control output. Mechanical 5.000.000; Electrical 100.000 operation at 250V AC, 5A (resistive load). Mechanical 30.000.000; Electrical 300.000 operation at 250V AC 8A (resistive load). Mechanical 30.000.000; Electrical 100.000 operation at 250V AC 16A (resistive load). CONTROL Control algorithm A/D converter Sampling time Proportional band Control period Hysteresis Output power 12 bit 100ms Adjustable between 0% and 100%. If Pb=0%, On-Off control is selected. Adjustable between 1 and 250 seconds Adjustable between 1 and 50°C/F The ratio of power at a set point can be adjusted between 0% and 100% HOUSING Housing type Dimensions Weight Enclosure material Suitable for flush-panel mounting according to DIN 43 700. W54xH94xD68mm Approx. 190g (after packing) Self extinguishing plastics. Avoid any liquid contact when the device is switched on. DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents. SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Open the catalog to page 1
ET5011 - 2

Entering from the programming mode to the run mode: If no key is pressed within 20 seconds during programming mode, the data is stored automatically and the run mode is entered. key is pressed while holding key, the programming mode is enabled. Alternatively, the same function occurs first pressing together, data is recorded and running mode is entered. key is pressing programming mode is entered.Then C.s.lo.= Control set point lower limit.(for selected output) Adjustable between 0 and C.s.Hi. C.s.Hi.= Control setpoint upper limit.(for selected output) Adjustable between C.s.Lo. and Upper...

Open the catalog to page 2
ET5011 - 3

( 1 ) Measurement value and set value indicator Running mode) Parameter name and value (Programming mode) ( 2 ) Value increment key (Programming mode) If only this key is pressed in normal operation,software version number is seen. ( F.k.E.C. parameter processing) ( 3) Value decrement and parameter selection key (Programming mode). ( 4 ) Control set selection key (Running mode) Parameter set key (Programming mode) 7 segment, 4 digits red LED display 12 mm Character heights ( 2 ),( 3 ),( 4 ) Keypad Micro switch Control outputs 1 digits red LED Mounting the device to the rail : Push the...

Open the catalog to page 3

All ENDA catalogs and technical brochures

  1. ENDA EDP2041

    4 Pages

  2. END003/004/214

    18 Pages

  3. EHTC7425A

    8 Pages

  4. EPC9513

    10 Pages

  5. ET4430

    7 Pages