Overview: The document outlines the technical specifications and operational guidelines for the ENDA ET4430 PID Temperature Controller, emphasizing adherence to instructions to maintain warranty and prevent damage.
Specifications:
  • Input Types: Supports thermocouples (J, L, K, T, S, R) and PT100 resistance thermometers.
  • Accuracy: 0.5% for full scale, 0.2% for PT100.
  • Environmental Conditions: Max height 2000m, operating temperature 0 to +50°C, storage temperature -25 to +70°C, humidity up to 80% at 31°C.
  • Electrical Characteristics: Supply voltage 90-250V AC or 10-30V DC, max power consumption 5VA.
  • Outputs: Relay outputs with 30 million switches life expectancy, SSR output max 24V 20mA.
Control Features:
  • Supports On-Off, P, PI, PD, and PID control algorithms with a 14-bit A/D converter and 100ms sampling time.
  • Proportional band adjustable 0.0% to 100.0%, control period 1 to 125 seconds.
  • Includes self-tuning and manual PID parameter entry.
Installation and Safety:
  • Mount in control panel, protect from humidity, vibrations, and soiling.
  • Connections by qualified personnel per local regulations.
  • Avoid exposure to corrosive, volatile, or flammable substances.
Communication and Configuration:
  • Supports RS485 Modbus RTU protocol.
  • Features dual setpoint selection, soft-start, and alarm configurations.
Dimensions and Housing:
  • Dimensions: W48xH48xD87mm, weight 250g, self-extinguishing plastics.
  • Front panel IP65, rear panel IP20 per EN 60529.
Additional Notes:
  • Ensure proper grounding, avoid liquid contact when powered.
  • Refer to Modbus Address Map and Connection Diagram Guide for setup.
Additional Specifications:
  • Output Power on Probe Failure: Adjustable 0% to 100%, determines output state on failure.
  • Soft Start Timer: Adjustable 0 to 250 minutes, 0 cancels feature.
  • Output Control Type: Options for heating and cooling control.
Alarm Configurations:
  • Alarm1 and Alarm2 Settings: Set value limits, hysteresis, types (independent, deviation, band, band with inhibition).
  • Alarm Conditions on Probe Failure: Set outputs ON or OFF on failure.
Input and Output Settings:
  • Input Type Selection: PT100 and thermocouples (J, K, L, T, S, R).
  • Control Output Selection: Relay and SSR output options.
Communication Protocols:
  • RS485 ModBus: Address 1 to 247, baud rates 2400 to 38400 bps.
Security and Access Levels:
  • Security Access Levels: Parameters set to visible, invisible, or modifiable.
  • Security Menu Access Code: Code 430 for access.
Additional Features:
  • Self-Tune Control: Automatic tuning with start/stop conditions.
  • Digital Filter Coefficient: Adjustable 1 to 200 for value filtering.
See more

Catalog excerpts

ET4430-1

Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. ENDA ET4430 PID TEMPERATURE CONTROLLER Thank you for choosing ENDA ET4430 Temperature Controller Devices. 48x48mm sized. Dual setpoint value selection. PT100 ,J, K, L, T, S, R sensor type selections. Auto calculation for PID parameters (SELF TUNE). Self tune for automatic PID calculation or manually enter PID parameters if known. Three different feature assignments for digital input. Three different feature assignments for the function (F) key. Soft-Start feature. SSR or Relay Output Control selection. A1 Relay output programmable as primary Alarm or PID Cooling Control output. C/A2 Relay output can be used as secondary Alarm or Temperature Control output. Heating/Cooling control selection. Zero point input shift. In case of sensor failure, periodically, auto-periodically running or relay state can be selected. RS485 Modbus RTU communication protocol feature (Specify at order). CE marked according to European Norms. TEMPERATURE CONTROLLER Input Type PT100 Resistance Thermometer PT100 Resistance Thermometer J (Fe-CuNi) Thermocouple J (Fe-CuNi) Thermocouple K (NiCr-Ni) Thermocouple K (NiCr-Ni) Thermocouple L (Fe-CuNi) Thermocouple L (Fe-CuNi) Thermocouple T (Cu-CuNi) Thermocouple T (Cu-CuNi) Thermocouple S (Pt10Rh-Pt) Thermocouple R (Pt13Rh-Pt) Thermocouple Accuracy 0,2% (for full scale) 0,2% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 0,5% (for full scale) 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit 1 digit ENVIRONMENTAL CONDITIONS Ambient/storage temperature Max. Relative humidity Rated pollution degree Height 0 ... +50°C/-25 ... +70°C Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C. Front panel Rear panel : KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations. ELECTRICAL CHARACTERISTICS Supply Power consumption Wiring Line resistance Data retention 90-250V AC 50/60Hz, 24V AC ±%10 50/60Hz or 10-30VDC / 8-24VAC ±%10 SMPS Max. 5VA Power screw-terminal connections: 2.5mm²', Signal screw-terminal connections: 1,5mm². Max. 100 Ohm EEPROM (minimum 10 years) EN 61326-1: 2013 (Performance criterion B satisfied for EN 61000-4-3 standard). EN 61010-1: 2010 (Pollution degree 2, overvoltage category II) OUTPUTS C/A2 Output A1 Output SSR Output Life expectancy for relay Relay : 250V AC, 10A (for resistive load), NO+NC (Control or Alarm2 Output selection). Relay : 250V AC, 5A (for resistive load), NO (Alarm1 and Cooling Control Output selection). Max. SSR Output ; 24V 20mA. Without load 30.000.000 switching; 250V AC, 8A (resistive load) 300.000 switching. CONTROL Control type Control algorithm A/D converter Sampling time Proportional band Control period Hysteresis Output power Single Setpoint and Alarm Control. On-Off / P, PI, PD, PID selection. 14 bit. Min. 100ms. Can be adjusted between %0.0 and %100.0 . If Pb=%0.0 , ON-OFF control is selected. Can be adjusted between 1 and 125secs. Can be adjusted between 1 and 50°C/F. Setpoint value ratio can be adjusted between %0 and %100 . HOUSING Housing type Suitable for flush-panel mounting according to DIN 43 700. Weight Enclosure material Approx. 250g Self extinguishing plastics Avoid any liquid contact when the device is switched on. DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents. TM SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş. Şerifali Mah. Barbaros Cad. No:18 Y.Dudullu 34775 ÜMRANİYE/İSTANBUL-TURKEY Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url

 Open the catalog to page 1
ET4430-2

DIMENSIONS Depth To removing the device from the panel : - While pressing both side of the device in direction 1 and push it in direction 2 . TEMPERATURE CONTROLLER Connection Cables 1) While panel mounting, additional distance required for connection cables should be considered. 2) Panel thickness should be 9mm maximum. 3) If there is no free space at back side of the device, it would be difficult to remove it from the panel. 100mm clearance should be left behind the device. Flush mounting clamp Panel Equipment is protected throughout by DOUBLE INSULATION CONNECTION DIAGRAM ENDA ET4430 PID Temperature...

 Open the catalog to page 2
ET4430-3

( 1 ) Indicates measured value and set values in “Running Mode”. Indicates the parameters and names in “Programming Mode”. TEMPERATURE CONTROLLER ( 2 ) Increment key in “Running Mode” and “Programming Mode”. Parameter selection key in “Programming Mode”. ( 3 ) Decrement key By pressing this key in “Running Mode”, software version can be displayed. Parameter selection key in “Programming Mode”. ( 4 ) Selectable function key “Running Mode”. Menu selection key in “Programming Mode”. FF ( 5 ) Control and Alarm set key in “Runnig Mode”. Parameter set key in “Programming Mode” PV 7 Segment 4 digits...

 Open the catalog to page 3
ET4430-4

ENDA ET4430 PROGRAMMING DIAGRAM ENTERING TO PROGRAMMING MODE If key is pressed while holding A1.S.L a1.s.l = Alarm1 set value lower limit. -30 Can be adjusted between 0 and C.s.Lo. C.s.lo. = Lower limit for C/A1 Output control, setpoint value. -30 Can be adjusted between 0 and C.s.Hi. 600 key, the "Programming Mode" is entered. RUNNING MODE During in "Programming Mode", if no key is pressed for 20 sec, settings automatically saved and device returns to the "Running Mode" (to the home key "Running Mode" is entered and by pressing both keys at once, settings automatically screen). Alternatively,...

 Open the catalog to page 4

All ENDA catalogs and technical brochures

  1. ENDA EDP2041

    4  Pages

  2. END003/004/214

    18  Pages

  3. EHTC7425A

    8  Pages

  4. EPC9513

    10  Pages

  5. ET5011

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.