Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. END003/004/214 DIGITAL THERMOSTAT Thank you for choosing END003/004/214 Temperature Controller. * ON / OFF Cooling control * 4 Relay Output for Cooling, Fan, AUX , Defrost (In the END003 product the defrost / aux output is taken from the same place and there are 3 relay outputs) * AUX Output can be set to Alarm or Lighting (Defrost output can not be used in END004 and END214 products.) * 3 NTC Probe inputs for Cell ,Evaporator and Condenser * Digital Input (Door Switch) * Multifunction digital input (It is only available in END214.) * Offset value can be entered for NTC input * Compressor protection parameters can be entered. * In case of probe failure, output status can be set to * Manuel fast cooling feature * Manuel or depending on Time and Evaporator defrost feature * Defrost dureation and intervals can be set. * Upper and Lower sepoint limits can be set. * Up to 3 HACCP alarm record can be stored. (9 alarm record in END214) * Real Time Clock feature (It is only available in END214.) * Android App (In Google Play™ Store : END214 Connect) (It is only available at END214.) * Temperature unit can be displayed as ° F or ° C . * CE marked according to European Norms. * RS485 - ModBus RTU communication feature TECHNICAL FEATURES ENVIRONMENTAL CONDITIONS Ambient/Storage Temp. 0 ... +50°C/-25 ... 70°C (Without İcing) 80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C. Relavite Humidity EN 60529 Protection Class Height Max 2000m Do not use the device in locations subject to corrosive and flammable gasses ELECTRICAL CHARACTERISTIC Supply Voltage 230V AC +%10 -%20, 50/60Hz Max 2VA Power Consumption Connection 2.5 ve 1.75 mm²'lik screw-terminal conneciton -60.0 ... +150.0°C (-76.0 ... +302.0°F) Scale 0.1°C (Can be selected as 0.1ºC or1ºC ) Sensitivity ±1°C Accuracy ±%1 Time Accuracy 4 Digits, 60x26mm 7 Segment Led,15 Warning Led. Display EN 61326-1: 2013 EMC Safety Requirements EN 61010-1: 2010 (Pollution Degree 2, Overvoltage Category II) RELAYS Compressor Relay Output Fan Relay Output AUX Relay Output Defrost Relay Output (!)END003 does not exist OUTPUTS Control Type Control Method Hysterisis for Resistive load : NO 277V AC 20A , for inductive load: 2hp 250V AC Relay Life: Unload 10.000.000 switching, 277V AC 20A rezistive load 100.000 switching. for Resistive load : NO 250V AC 8A 1/2hp 240V AC Relay Life : Unload 30.000.000 switching, 250V AC, 8A rezistive load 100.000 switching for Resistive load : NO/NC 250V AC 8A , inductive load: 1/2hp 240V AC Relay Life: Unload 30.000.000 switching, 250V AC, 8A resistive load 100.000 switching for Resistive load : NO/NC 250V AC 8A , inductive load: 1/2hp 240V AC Relay Life: Unload 30.000.000 switching, 250V AC, 8A rezistive load 100.000 switching Setpoint Control ,Compressor with digital Input ,Defrost,Output Control Of Fan. On-Off Control Adjustable between 0.1 ... 20.0°C. 1/14
Open the catalog to page 1FRONT PANEL COMMANDS LED Description ON / OFF Led - If led is on , device don't work. - If led is off , device work. Lighting Led -if AUX is set as lighting and output is active, led is on. If ligthing activated by digital input,led is blinking. Compressor Led - If led is on , compressor is on. - If led is blinking, then protecting delay active - If led is off , compressor is off. Defrost Led - If led is on , defrost is in progress. - If led is blinking, dripping in progress. - If led is off , defrost is off. Fan Led - If led is on , fan is on. - If led is blinking, then protecting delay...
Open the catalog to page 2Silencing the Buzzer When an alarm condition occurs, an audible alarm is triggered. The audible alarm can be switched off by pressing any key. Manuel Defrost Progress Manual defrost operation is started by pressing and holding DEFR key for 4 seconds in the operation mode (when the key is not locked, when overcooling is not working and the evap. temperature is lower than the defrost termination temperature).. Manuel Overcooling In the operating mode (when there is no key lock, the device is not in defrost mode and the dripping duration is not active), pressing DOWN key for 4 seconds starts...
Open the catalog to page 3Display of Compressor Run Time -15.0 Measurement value DOWN If the DOWN key is pressed,enter menu that the alarm and other information are displayed . The UP and DOWN keys are used to select the CH message. Pressing the SET key will display the running time of the compressor. When the CH message is displayed and you want to return to the operating mode at any point in the operation, you must press the ON or wait for 15 seconds without pressing any key at any point in the operation. The compressor run time can be stored up to 9999 hours. Reset of Compressor Run Time Measurement value DOWN If...
Open the catalog to page 4PARAMETER LIST CONFIGURATION PARAMETRES NAME PARAMETER DESCRIPTION Working setpoint; see also r0 Offset cell probe Offset evaporator probe Offset condenser probe evaporator probe function 0 : probe absent 1 : defrosting probe and probe for evaporator fan thermostatisation 2 : probe for evaporator fan thermostatisation enabling of condenser probe 0 : NO 1: YES delay in display of variations in temperature detected by the probes MAIN CONTROL PARAMETERS NAME PARAMETER DESCRIPTION Working setpoint differential Minimum working setpoint Maximum working setpoint Locking of working setpoint...
Open the catalog to page 5DEFROST PARAMETERS NAME d0 PARAMETER DESCRIPTION If d8 = 0, 1 or 2, defrosting interval If d8 = 3, maximum defrost interval 0 = interval defrosting will never be activated d1 Type of defrosting 0 = ELECTRIC - during defrosting the compressor will remain off and the defrosting output will be activated; evaporator fan activity will depend on parameter F2 1 = BY HOT GAS - during defrosting the compressor will be switched on and the defrosting output will be activated; evaporator fan activity will depend on parameter F2 2 = VIA STOPPING OF COMPRESSOR - during defrosting the compressor will...