Overview: The document outlines the specifications and functionalities of the power supply systems for the Global Maritime Distress and Safety System (GMDSS), which are designed to ensure reliable power for maritime communication and emergency systems across various operational zones (A1/A2/A3/A4). These systems comply with international and national maritime regulations and are certified by Bureau Veritas.
Specifications: The power supply systems, including the FCA, ICA, and FCC ranges, provide automatic switchover between main and emergency power sources without interruption. They are compliant with IMO regulations, French regulations (Division 219), and CEI 945 standards for bridge equipment. The systems feature multiple protected outputs to power various communication devices such as MF emitters, VHF ASN, Inmarsat C, GPS, and emergency lights.
Functions: Key functions include automatic switchover of power sources, regulated and filtered power supply, protection against voltage surges, control of battery charge/discharge, and status display through light indicators and alarms. The systems also perform periodic autonomy tests and under-voltage tests.
Power Supply Selection: The document details the selection criteria for power supply systems based on the ship's operational zones and compliance with Chapter 2 and Chapter 3 regulations. It emphasizes the importance of regulated power supply chargers, protection mechanisms, and alarm systems for ensuring the security of radio electric installations.
Technical Specifications: The document provides detailed technical specifications for different models within the FCA, ICA, and FCC ranges, including input and output characteristics, main functions, interface and display options, and mechanical and environmental characteristics. It highlights the importance of certified battery chargers and compliance with CISPR 16 standards for installations with AC main networks.
Recommendations: The document recommends specific ENAG equipment for different configurations and operational needs, ensuring compliance with maritime safety standards and enhancing the reliability of maritime communication systems.
See more

Catalog excerpts

GMDSS Range-1

Electrical power supply GMDSS Range for Global Maritime Distress and Safety System (GMDSS) The power supply range FCA / ICA / FCC for GMDSS covers all vessel nationalities in the following areas of application: • Type of ship • Scope of application - title 2 and 3 • Operation zones A1/A2/A3/A4 Installed on ship, these power supplies provide power from several available sources of energy to the radio system and the emergency communication system. They insure an automatic switchover without cut-off between the main power source and the emergency power source. This power supply range is compliant with the requirements of the International Maritime Organisation (IMO), the French regulations (Division 219 - October 2000) and for equipment installed on the Bridge (CEI 945 Standard) The complete range is certified by Bureau Veritas -CERTIFICATE N° 10528/D1/BV The power supplies integrate the following functions: connection, protection, display, warning and switchover. The display can be integrated on the cabinet or can be remotely installed on a support close to the user. With the configuration of 6 protected outputs, the system can power for example: 1 emitter MF, 1 VHF ASN, 1 VHF ASN (duplication), 1 Immarsat C, 1 GPS, 1 emergency light indicator.

 Open the catalog to page 1
GMDSS Range-2

Power Supply selection 1. Power supply systems specified in the field of application for Chapter 2 or for all ships equipped with an INMARSAT system. A1/A2/A3/A4 oceanic areas - French or foreign ships Functions provided by ENAG power supply systems in accordance with Division 219-13 and IMO regulation • Automatic switchover, without disconnection of 3 power supply sources, • Regulated and filtered power supply charger unit in accordance with CEI 945 standard, • Protection of the radio electric equipment against primary source voltage surge, • Control of the charge/discharge voltage and current...

 Open the catalog to page 2
GMDSS Range-3

FC-GMDSS-EN-E The information contained in this leaflet is not of a contractual nature. ENAG reserves the right to amend the technical details of its products without advance notice. ENAG S.A.S. - 31 Rue Marcel Paul - Z.I. Kerdroniou Est - 29000 Quimper- France Tel: + 33 2 98 55 51 99 - Fax: + 33 2 98 55 51 67 - E-mail: [email protected] Site : www.enag.fr

 Open the catalog to page 3
GMDSS Range-4

Note: • In an existing installation with AC main network, the FCC GMDSS RAE system may be installed in association with a battery charger. In this case, the charger must satisfy the following requirements: o It must have type approval or be certified by an approved organisation (BV, LLOYDS, ...), o It must meet the CISPR 16 standard (able to operate as a DC power supply), o It must have the "OVER SHOOT INHIBITED" function, o Any other configuration is prohibited as specified by regulations. • The FCC-GMDSS reference SEEL008462 can be used for Title 3 only and cannot be associated with a battery charger...