1. Catalogs
  2. Emmegi Heat Exchangers
  3. Air-Oil Heat Exchangers HPV

Air-Oil Heat Exchangers HPV

Air-Oil Heat Exchangers HPV
1 / 25 PagesView full catalog

Air-Oil Heat Exchangers HPV

Product catalog summary
Introduction
EMMEGI air-oil heat exchangers are engineered for cooling hydraulic systems using ambient air. They feature a durable aluminum alloy cooler element, enhancing fluid turbulence and heat exchange efficiency. The HPV Series includes an integrated by-pass valve, eliminating the need for an external valve and ensuring high functionality.
Compatible Fluids
  • Mineral Oils (HL, HLP)
  • Water-Oil Emulsion
  • Water-Glycol
  • Consult EMMEGI for other fluids
Technical Specifications
  • Material: Long-life aluminum
  • Operating Pressure: 20 bar
  • Test Pressure: 35 bar
  • Max Operating Temperature: 120°C
  • Contact EMMEGI for aggressive atmospheres
Installation
Exchangers can be installed horizontally or vertically to ensure natural cooling air flow. They should be protected from mechanical impacts and vibrations, connected with flexible pipes, and not exposed to sudden flow changes or pulsations.
Maintenance
Regular cleaning is crucial for maintaining thermal efficiency. For oil side cleaning, dismantle and flush with a compatible de-greasing substance. For air side cleaning, use compressed air or water, ensuring the electric motor is disconnected and protected.
Example of Heat Exchanger Selection
Calculate the specific heat exchange power (KW/°C) using the power to dissipate and the temperature difference between oil input and ambient temperature. Use catalogue graphs to select the appropriate model.
Technical Data and Performance
Performance diagrams and technical data are available for various models, detailing power, flow rates, and pressure drops. The selection includes models with different fan motor types and thermostat options.
See more

Catalog excerpts

Air-Oil Heat Exchangers HPV-1

Scambiatori Aria-olio Serie HPV Air-oil heat-exchangers HPV Series

 Open the catalog to page 1
Air-Oil Heat Exchangers HPV-2

Gli scambiatori di calore aria-olio EMMEGI, sono impiegati per il raffreddamento di circuiti oleodinamici usando, come fluido raffreddante, l’aria ambiente convogliata sulla radiante da una ventola azionata da un motore elettrico o idraulico. La massa radiante, in lega d’alluminio ad alta resistenza, è ottenuta mediante un processo costuttivo di saldobrasatura sottovuoto. La particolare configurazione dei condotti aumenta la turbolenza del fluido e di conseguenza la capacità di scambio; inoltre la presenza di speciali turbolatori sull’ alettatura del pacco radiante, migliora ulteriormente il...

 Open the catalog to page 2
Air-Oil Heat Exchangers HPV-3

É buona norma prestare particolare attenzione alla pulizia della massa radiante per garantire un naturale ricambio d’ aria ed evitare una diminuzione dell‘ efficenza termica. You should be particularly carefully in cleaning the cooler element to guarantee a natural exchange of air, in order to prevent a reduction in thermal efficiency Pulizia lato olio Per eseguire la pulizia lato olio, lo scambiatore dovrà essere smontato. Lo sporco può essere rimosso flussando in controcorrente un prodotto sgrassante, compatibile con alluminio. Effettuare un lavaggio con olio idraulico prima di ricollegare...

 Open the catalog to page 3
Air-Oil Heat Exchangers HPV-4

Dati tecnici Technical Data P/N V Hz kW A 2V3003 # # # 230-400 AC B14 50/60 0,750 1,8 2V3012 # # # 12 DC / 0,150 9,5 2V3024 # # # 24 DC / 0,150 5,6 2V3056 # # # Prepared for Gr.2 hydraulic motor Per il 12-24V i dati sono riferiti al singolo ventilatore For 12-24V the data refers to each ventilator Contattare EMMEGI Contact EMMEGI Diagramma rendimento Performance diagram Kw/°C 1,2 Lo scambiatore selezionato risulta il modello: HPV 30 - 230/400 - 50Hz cod. 2V3003###. The exchanger selected is the following model: HPV 30 - 230/400V - 50Hz cod. 2V3003###. Per la completa identificazione dello scambiatore...

 Open the catalog to page 4
Air-Oil Heat Exchangers HPV-5

Collegamenti elettrici Electric Wiring °C = Termostato NA./Thermostat No. K = Relè/Relay 4 CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 5
Air-Oil Heat Exchangers HPV-6

Modulo richiesta dati Sheet for cooler selection CLIENTE COMPANY RICHIEDENTE NAME ARIA-OLIO AIR-OIL PORTATA OLIO OIL FLOW RATE POTENZA INSTALLATA TOTAL POWER TEMPERATURA INGRESSO OLIO OIL TEMPERATURE INLET TEMPERATURA ARIA MAX VISCOSITÀ OLIO PRESSIONE DI LAVORO WORKING PRESSURE TIPO DI VENTILAZIONE TYPT OF FAN UNIT CORRENTE CONTINUA DIRECT CURRENT PREDISTOSTO MOTORE IDRAULICO PREPARATED FOR HYDRAULIC MOTOR CORRENTE ALTERNATA ALTERNATE CURRENT TENSIONE SPECIALE SPECIAL VOLTAGE 50 HZ CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 6
Air-Oil Heat Exchangers HPV-7

Denominazione codice prodotto Ordering code TIPO DI SISTEMA COOLER SERIES V24 TIPO DI MOTORIZZAZIONE FAN MOTOR TYPE 01 03 04 12 24 56 AC 230V 50 Hz AC 230V-400V 50Hz AC 230V-400V 50-60 Hz (B14) DC 12V DC 24V Pred. per mot. idr. gr. 2 Prep. for hydr. mot. gr. 2 Termostato fisso Fixed thermostat Termostato fisso Fixed thermostat Termostato fisso Fixed thermostat Termostato fisso Fixed thermostat Termostato fisso Fixed thermostat Termostato fisso Fixed thermostat Termostato regolabile Adjustable thermostat Termostato regolabile collegato Connected adjustable thermostat TIPO DI VENTILAZIONE VENTILATING...

 Open the catalog to page 7
Air-Oil Heat Exchangers HPV-8

Dati tecnici valvola by-pass Technical data by-pass valve - (1.5 bar) Valvola cartuccia tipo 2 / Cartridge valve type 2 - (1.5 bar) Perdite di carico Pressure drop P-bar Gli scambiatori aria -olio serie HPV- nascono dalle esigenze applicative ad ampio raggio espresse dal mercato. Punto di forza di questi prodotti é rappresentato dal by-pass integrato che ne amplifica la semplicità d‘ uso, eliminando la necessità di dovere aggiungere da parte del cliente una valvola autonoma, assicurando così elevata funzionalità. Valvola cartuccia tipo 3 / Cartridge valve type 3 - (1.5 bar) Perdite di carico...

 Open the catalog to page 8
Air-Oil Heat Exchangers HPV-9

Valve by pass - Type 2 P/N 2V1256### Le dimensioni di ingombro e le caratteristiche tecniche non sono impegnative Over-all dimensions and technical characteristic are not binding 8 CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 9
Air-Oil Heat Exchangers HPV-10

Dati tecnici Technical Data P/N V Hz kW A 2V1203 # # # 230-400 B14 AC 50/60 0,250 0,7 2V1212 # # # 12 DC / 0,160 11,3 2V1224 # # # 24 DC / 0,160 6,3 2V1256 # # # Prepared for Gr.2 hydraulic motor Contattare EMMEGI Contact EMMEGI Diagramma rendimento Performance diagram Kw/°C HYDR.3000 rpm Fattore di correzione - F -( perdite di carico) Correction factor - F - (Pressure drop) cst F CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 10
Air-Oil Heat Exchangers HPV-11

Valve by pass -Type 2 Le dimensioni di ingombro e le caratteristiche tecniche non sono impegnative Over-all dimensions and technical characteristic are not binding 10 CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 11
Air-Oil Heat Exchangers HPV-12

Dati tecnici Technical Data P/N V Hz kW A 2V1803 # # # 230-400 B14 AC 50/60 0,370 0,95 2V1812 # # # 12 DC / 0,210 13,3 2V1824 # # # 24 DC / 0,210 9,3 2V1856 # # # Prepared for Gr.2 hydraulic motor Contattare EMMEGI Contact EMMEGI Diagramma rendimento Performance diagram Kw/°C 0,7 Fattore di correzione - F -( perdite di carico) Correction factor - F - (Pressure drop) cst F CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 12
Air-Oil Heat Exchangers HPV-13

Valve by pass - Type 2 P/N 2V2456### Le dimensioni di ingombro e le caratteristiche tecniche non sono impegnative Over-all dimensions and technical characteristic are not binding 12 CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 13
Air-Oil Heat Exchangers HPV-14

Dati tecnici Technical Data P/N V Hz kW A 2V2403 # # # 230-400 B14 AC 50/60 0,550 1,35 2V2412 # # # 12 DC / 0,210 13,2 2V2424 # # # 24 DC / 0,210 8,4 2V2456 # # # Prepared for Gr.2 hydraulic motor Contattare EMMEGI Contact EMMEGI Diagramma rendimento Performance diagram Kw/°C 0,8 Perdite di carico Pressure drop ( ISO VG 32) bar 1 0,8 0,6 0,4 0,2 0 Fattore di correzione - F -( perdite di carico) Correction factor - F - (Pressure drop) cst F CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 14
Air-Oil Heat Exchangers HPV-15

Valve by pass -Type 3 Le dimensioni di ingombro e le caratteristiche tecniche non sono impegnative Over-all dimensions and technical characteristic are not binding 14 CATALOGO PRODOTTI PRODUCTS CATALOGUE

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.