TFE R-22 Series

TFE R-22 Series

Product catalog summary
Features
  • Stainless steel power element to prevent corrosion and valve failure.
  • Replaceable power element for ease of maintenance.
  • External superheat adjustment for precise control.
  • ODF connections for soldering.
  • Balanced port construction to handle varying operating pressures.
  • Bi-directional control capacity for flexible operation.
  • External equalizer for pressure balance.
Specifications
  • Maximum working pressure: 450 psig.
  • Designed for large tonnage heat pump, air conditioning, and commercial refrigeration applications.
Nomenclature Example

TFES 10 HCA 5/8 x 7/8 ODF S/T

  • Valve Series: Balanced Port, Replaceable Power Assembly.
  • Equalizer: E=External ¼” ODF.
  • Connection Type: S = solder (Only).
  • Capacity: Nominal Rating in Tons.
  • Refrigerant Code: H = R-22, M = R-134a, N = R-407C, P = R-507, R = R-502, S = R-404A.
  • Charge Code: C = medium temp, CA = heat pump.
  • Inlet x Outlet Connection Sizes.
  • Configuration: S/T = Straight-thru.
Nominal Capacity Table (in Tons)
RefrigerantCapacity
R-134a6, 8, 10, 15
R-22/R-407C8, 10, 12, 20
R-502, R-404A/R-5075, 7, 9, 14
Ordering Information
  • Valve Series: TFES.
  • Capacity Tons (R-22 Nominal): 8, 10, 12, 20.
  • Connections: 5/8 X 7/8 ODF S/T.
  • PCN: 6A ODF EE 061608, 6A ODF EE 061610, 6A 061609, 6A 064493.
Inlet/Outlet Fittings Dimensional Data (in)

Various configurations with dimensions provided for different ODF sizes.

Remote Bulb Charge Tubing Length (Ft)
  • Options: 2, 2-1/2, 5, 10, 15, 20, 30, 40, 50.
Replacement Parts
  • Power Assembly: X-28458 HCA-2 063414, X-28458 HW100-2 063416, X-28458 SW45-2 065298.
  • Seal Nut: 27676-1 058707.
See more

Catalog excerpts

TFE R-22 Series-1

Thermal Expansion Valves The TFE R-22 series is designed for large tonnage heat pump, air conditioning, and commercial refrigeration applications. Stainless steel power element eliminates corrosion and prevents valve failure Replaceable power element External superheat adjustment ODF connections Balanced port construction compensates for changes in operating pressures due to varying ambients, or widely varying evaporator loads Bi-Directional control capacity External equalizer • Maximum working pressure: TFE Nominal* Capacity Table in Tons R-134a 6 8 10 15 *See Extended Capacity Tables for ratings at a wide range of conditions per ARI standard 750 Nomenclature example: TFES 10 HCA 5/8 x 7/8 ODF S/T TF Valve Series Balanced Port, Replaceable Power Assembly Connection Type Refrigerant Code Charge Code C = medium temp CA = heat pump Inlet x Outlet Connection Sizes (See ordering information table below) Connection Type Capacity Nominal Rating in Tons (See nominal capacity table below) * = R-507, R-502 and R-404A are interchangeable refrigerant charges, • = R-22 and R-407C are interchangeable refrigerant charges Ordering Information Valve Capacity Tons* Series (R-22 Nominal) TFES PCN HCA Charge (R-22 Heat Pump) 061608 061610 061609 064493 Inlet/Outlet Fittings Dimensional Data (in) Connections Inlet Outlet Remote Bulb Charge Replacement Parts Power Assembly Seal Nut Emerson Climate Technologies

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.