Coils for Solenoid Valves Solenoid Valves & Coils • Compact designs • Coil windings are insulated to provide shock and vibration protection • ASC2 is designed to provide weather protection • Interchangeable housings Voltage Options • • • • • • • Requires ASC2 female connector (PCN 059261). 24V 50/60 Hz 120V 50/60 Hz (standard) 208-220/208-240V 50/60 Hz 480V 50/60 Hz 120-240V 50/60 Hz 12V D.C. (MM Series recommended) 24V D.C. (MM Series recommended) Coil Code Series A = 12 Watt B = 15 Watt C = 18 Watt D = 7 Watt M = 4 Watt Insulation B or G = Class B M = Class F H = Class H MAGMAX Coil (Type MM): For Use On DC Applications Only Enclosure C = Conduit Connection F = Open Frame Leads G = Junction Box L = Grommet 18” Leads S = Spade Connection Amperes Holding Solenoid Coil Prefix Selection Table Valve Type Molded-DIN With Connector * SML is OEM - RMF is Wholesale replacement Note - All coils NEMAI except ASC2 NEMA2 Nominal Voltage and Frequency Applied Voltage and Frequency See the MM (MAGMAX) Series Coil for DC Applications Emerson Climate Technologies
Open the catalog to page 1Coils for Solenoid Valves AM Coil: Solenoid Valves & Coils Amperes Applied Voltage and Frequency Nominal Voltage and Frequency Coil Insulation Coil Insulation See the MM (MAGMAX) Series Coil for DC Applications Applied Voltage and Frequency Nominal Voltage and Frequency See the MM (MAGMAX) Series Coil for DC Applications Nominal Voltage and Frequency Applied Voltage and Frequency Coil Insulation See the MM (MAGMAX) Series Coil for DC Applications Emerson Climate Technologies
Open the catalog to page 2Coils for Solenoid Valves ASC2 Coil: 200RB/200RD 540RA Solenoid Valves & Coils Amperes Nominal Voltage and Frequency Applied Voltage and Frequency Nominal Voltage and Frequency Applied Voltage and Frequency Nominal Voltage and Frequency Applied Voltage and Frequency Nominal Voltage and Frequency Applied Voltage and Frequency Nominal Voltage and Frequency Applied Voltage and Frequency RMS/RMF Coil: Coil Insulation Coil Insulation Coil Insulation Coil Insulation Coil Insulation Emerson Climate Technologies
Open the catalog to page 3Coils for Solenoid Valves Solenoid Valves & Coils Ordering Information AMG Junction Box 6” Leads Voltage / Frequency Dual Voltage Wiring Diagram AM and ASC 2 style DC coils should not be used for direct replacements on OEM equipment. The use of this coil on new applications may result in the valve not opening. New applications should use the MM coil because of the significant increase in opening power of the MM Coil over the standard AM and ASC 2 style DC coil. 2004FC-118 R13 (01/14) Coil Enclosure Options Options Open Frame - 18” Leads Open Frame - Spades Emerson Climate Technologies
Open the catalog to page 4All Emerson Commercial & Residential Solutions catalogs and technical brochures
-
valves and controls solution
2 Pages
-
General Product Catalogue 2021
322 Pages
-
General Product Catalogue 2021
322 Pages
-
1E78-151
2 Pages
-
Copeland Discus
2 Pages
-
Copeland Scroll ™ csd100
4 Pages
-
ACK Check Valves
1 Pages
-
TLE series
2 Pages
-
TXV Connect Kits
1 Pages
-
ZZ series
2 Pages
-
204CD
2 Pages
-
210CA and 211CA
2 Pages
-
214CB
2 Pages
-
222CB
2 Pages
-
314UB
2 Pages
-
50RB
2 Pages
-
100RB
2 Pages
-
200RB
3 Pages
-
200RD
2 Pages
-
240RA
2 Pages
-
500RB
2 Pages
-
540RA
2 Pages
-
Solenoid Multi-Purpose Tool
1 Pages
-
NXT Series
2 Pages
-
TFE R-410A
1 Pages
-
TI Series
1 Pages
-
TRAE - TRAE+ Series
3 Pages
-
A Series
3 Pages
-
HF Series
2 Pages
-
TFE R-22 Series
1 Pages
-
T Series - Take-Apart
4 Pages
-
HF - HFK Series
10 Pages
-
B Series - with strainer
3 Pages
-
BA/BN Series
3 Pages
-
AFA(E) Series
2 Pages
-
ACP(E) - Automatic
2 Pages
-
Valves & Controls Solution
2 Pages
-
EX Brochure
4 Pages
Archived catalogs
-
Pressure Regulator
49 Pages
-
System Protector
39 Pages
-
A-AS Suction Accumulators
1 Pages
-
Coils
3 Pages
-
Shut Off Valves
2 Pages
-
Solenoid Valve
25 Pages